Jinlian Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jinlian Du has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Xiao Zhang
College of Computer Science, Beijing University of Technology
4 shared publications - Meiyi Wu
College of Computer Science, Beijing University of Technology
2 shared publications - Xinyi Ding
Beijing University of Technology, Beijing, China
2 shared publications Fangyuan Luo
1 shared publication- Fangyuan Luo
College of Computer Science, Beijing University of Technology, Beijing, China
1 shared publication - Feng Guo
School of Computer Science (National Pilot Software Engineering School), Beijing University of Posts and Telecommunications, China
1 shared publication
Latest Publications
- 3 June 2026
- Published by Springer Nature
- p. 411-426
STSACM: A Method for Segmenting and Classifying Subjects in Chinese Electronic Medical Records
- 3 June 2026
- Published by Springer Nature
- p. 411-426
STSACM: A Method for Segmenting and Classifying Subjects in Chinese Electronic Medical Records
- Open Access
- 29 January 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Applied Perception
- Vol. 23 (2) , 1-17
Real-time Cognitive Load Measurement Using Wearable Photoplethysmogram Sensor
Measurement of the cognitive load in mobile situations using wearable devices plays important roles in smart human–computer interactions, physical health monitoring, mental health monitoring, and so forth in daily life. Among wearable devices, wristbands are similar to traditional watches and suitable for most scenarios, such as classrooms and offices; thus, they are widely accepted and becoming increasingly popular. However, most wristbands are only used for step counting and heart rate monitoring. In this article, we propose a cognitive load monitoring method based on wristband heart rate sensors. The sensors used to detect heart rate are generally photoplethysmogram sensors, but the current major manufacturers extract only the heart rate parameter of the photoplethysmogram. We make full use of the waveform of the wristband photoplethysmogram signal to measure real-time cognitive load and establish a real-time cognitive load measurement system, which expands the application scope of the wristband photoplethysmogram sensor and shows great potential for measuring cognitive load in daily life. In experimental validation using an n-back task, our waveform-based CNN model achieved approximately 20% higher accuracy in cognitive load classification versus traditional feature-based methods (e.g., LR, SVM, and GNB), reaching an average of 80.11%. The system successfully classifies the cognitive load and demonstrates the practical viability of the proposed approach.
- 29 January 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Applied Perception
- Vol. 23 (2) , 1-17
Open AccessReal-time Cognitive Load Measurement Using Wearable Photoplethysmogram Sensor
Measurement of the cognitive load in mobile situations using wearable devices plays important roles in smart human–computer interactions, physical health monitoring, mental health monitoring, and so forth in daily life. Among wearable devices, wristbands are similar to traditional watches and suitable for most scenarios, such as classrooms and offices; thus, they are widely accepted and becoming increasingly popular. However, most wristbands are only used for step counting and heart rate monitoring. In this article, we propose a cognitive load monitoring method based on wristband heart rate sensors. The sensors used to detect heart rate are generally photoplethysmogram sensors, but the current major manufacturers extract only the heart rate parameter of the photoplethysmogram. We make full use of the waveform of the wristband photoplethysmogram signal to measure real-time cognitive load and establish a real-time cognitive load measurement system, which expands the application scope of the wristband photoplethysmogram sensor and shows great potential for measuring cognitive load in daily life. In experimental validation using an n-back task, our waveform-based CNN model achieved approximately 20% higher accuracy in cognitive load classification versus traditional feature-based methods (e.g., LR, SVM, and GNB), reaching an average of 80.11%. The system successfully classifies the cognitive load and demonstrates the practical viability of the proposed approach.
- Open Access
- 12 December 2025
- Published by Association for Computing Machinery (ACM)
- p. 235-240
A Multimodal Diagnostic Model for Acute Abdominal Diseases: Integrating Structured Laboratory Data and Unstructured Clinical Narratives
- 12 December 2025
- Published by Association for Computing Machinery (ACM)
- p. 235-240
Open AccessA Multimodal Diagnostic Model for Acute Abdominal Diseases: Integrating Structured Laboratory Data and Unstructured Clinical Narratives
- Open Access
- 27 August 2025
- Published by Association for Computing Machinery (ACM)
- p. 114-122
The Research on GPU-Based Relational Join Algorithms
- 27 August 2025
- Published by Association for Computing Machinery (ACM)
- p. 114-122
Open AccessThe Research on GPU-Based Relational Join Algorithms
- Open Access
- 26 May 2023
- Published by Association for Computing Machinery (ACM)
- p. 167-172
Photoplethysmogram Based Cognitive Load Recognition Using Lstm
- 26 May 2023
- Published by Association for Computing Machinery (ACM)
- p. 167-172
Open AccessPhotoplethysmogram Based Cognitive Load Recognition Using Lstm