Yuyang Ming
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuyang Ming has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Min Peng
School of Safety Engineering, China University of Mining and Technology, Xuzhou, China
2 shared publications - Zhenkun Wu
School of Safety Engineering, China University of Mining and Technology, Xuzhou, China
2 shared publications Chunxiao Song
School of Safety Engineering China University of Mining and Technology Xuzhou PR China
1 shared publicationDing Li
1 shared publication- Dongzi Qin1 shared publication
Guoqing Zhu
School of Safety Engineering China University of Mining and Technology Xuzhou PR China
1 shared publication
Latest Publications
- 6 November 2023
- Published by Wiley in Fire and Materials
- Vol. 48 (3) , 299-310
Study on the influence of air supply and smoke exhaust on full transverse exhaust of long highway tunnel
This study investigated the efficacy of the full transverse exhaust method for smoke extraction in tunnel fires. It examines factors such as the number and layout of air supply and exhaust outlets, analyzing their impact on smoke spread, tunnel temperature, visibility, and airflow. The results demonstrate that the full transverse exhaust method effectively controls smoke emissions in raised highway tunnels. It limits smoke spread, reduces tunnel temperature, and effectively controls the fire‐affected area. The number and layout of outlets significantly influence smoke dispersion, with fewer exhaust outlets providing better smoke control and optimizing the tunnel environment. However, insufficient outlets disrupt gas flow stability. The position of exhaust outlets affects smoke distribution, and caution is advised to prevent directing fresh air flow toward the fire. Opening an equal number of exhaust outlets on one side of the fire source yields superior smoke extraction results, reducing tunnel ceiling temperatures and minimizing risks to personnel and structures. Though stabilization may take longer, this configuration proves advantageous. The study offers valuable insights and practical guidelines for implementing the full transverse smoke control method in real‐world scenarios.
- 6 November 2023
- Published by Wiley in Fire and Materials
- Vol. 48 (3) , 299-310
Study on the influence of air supply and smoke exhaust on full transverse exhaust of long highway tunnel
This study investigated the efficacy of the full transverse exhaust method for smoke extraction in tunnel fires. It examines factors such as the number and layout of air supply and exhaust outlets, analyzing their impact on smoke spread, tunnel temperature, visibility, and airflow. The results demonstrate that the full transverse exhaust method effectively controls smoke emissions in raised highway tunnels. It limits smoke spread, reduces tunnel temperature, and effectively controls the fire‐affected area. The number and layout of outlets significantly influence smoke dispersion, with fewer exhaust outlets providing better smoke control and optimizing the tunnel environment. However, insufficient outlets disrupt gas flow stability. The position of exhaust outlets affects smoke distribution, and caution is advised to prevent directing fresh air flow toward the fire. Opening an equal number of exhaust outlets on one side of the fire source yields superior smoke extraction results, reducing tunnel ceiling temperatures and minimizing risks to personnel and structures. Though stabilization may take longer, this configuration proves advantageous. The study offers valuable insights and practical guidelines for implementing the full transverse smoke control method in real‐world scenarios.