Hanbing Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hanbing Zhang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Aike Qiao
College of Chemistry and Life Science, Beijing University of Technology, Beijing 100124, China
3 shared publications - Tianming Du
Beijing International Science and Technology Cooperation Base for Intelligent Physiological Measurement and Clinical Transformation, Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, Beijing 100124, China
3 shared publications - Shiliang Chen
College of Chemistry and Life Science, Beijing University of Technology, Beijing 100124, China
2 shared publications - Yanping Zhang
School of Chemistry and Life Science, Beijing University of Technology Beijing China
2 shared publications - Jing Qi
Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
1 shared publication - Lifang Wu
Beijing University of Technology, China
1 shared publication
Latest Publications
- Open Access
- 14 June 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (6) , 296
Structural Optimization and Finite Element Analysis of Variable-Stiffness Biodegradable Vascular Stents
Premature structural failure of biodegradable vascular stents (BVSs) induced by stress corrosion cracking (SCC) remains a critical challenge. Heterogeneous plaques compress the stent, leading to inadequate expansion and inducing stress concentration that exacerbates SCC. This study proposes variable-stiffness stents to improve radial support and mitigate non-uniform degradation. The stents were designed with shortened axial ring segments and selective strut widening at the stenotic regions for targeted stiffness enhancement. They were virtually deployed in arteries with non-calcified and calcified plaques to evaluate immediate performance, while long-term service behavior was assessed via degradation simulation under combined electrochemical corrosion and SCC effects. The results show that variable-stiffness stents exhibited comparable residual stenosis to uniform-stiffness stents with identical local structures at plaque regions. Dual-stiffness designs yielded a smoother luminal profile than uniform-stiffness counterparts, and gradient-stiffness designs achieved further improvements. Local strut widening extended full recoil time, with a more marked effect on high-stiffness segments, by 52.6% and 41.2% in non-calcified and calcified plaques, while simultaneously increasing volume loss to mitigate non-uniform degradation. In addition, widened gradient-stiffness designs further prolonged the stable support time by 9.7%. These findings show variable-stiffness stents with widened gradient-stiffness design exhibit a more favorable immediate and long-term performance.
- 14 June 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (6) , 296
Open AccessStructural Optimization and Finite Element Analysis of Variable-Stiffness Biodegradable Vascular Stents
Premature structural failure of biodegradable vascular stents (BVSs) induced by stress corrosion cracking (SCC) remains a critical challenge. Heterogeneous plaques compress the stent, leading to inadequate expansion and inducing stress concentration that exacerbates SCC. This study proposes variable-stiffness stents to improve radial support and mitigate non-uniform degradation. The stents were designed with shortened axial ring segments and selective strut widening at the stenotic regions for targeted stiffness enhancement. They were virtually deployed in arteries with non-calcified and calcified plaques to evaluate immediate performance, while long-term service behavior was assessed via degradation simulation under combined electrochemical corrosion and SCC effects. The results show that variable-stiffness stents exhibited comparable residual stenosis to uniform-stiffness stents with identical local structures at plaque regions. Dual-stiffness designs yielded a smoother luminal profile than uniform-stiffness counterparts, and gradient-stiffness designs achieved further improvements. Local strut widening extended full recoil time, with a more marked effect on high-stiffness segments, by 52.6% and 41.2% in non-calcified and calcified plaques, while simultaneously increasing volume loss to mitigate non-uniform degradation. In addition, widened gradient-stiffness designs further prolonged the stable support time by 9.7%. These findings show variable-stiffness stents with widened gradient-stiffness design exhibit a more favorable immediate and long-term performance.
- Open Access
- 15 November 2023
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 14 (11) , 547
Numerical Simulation of Dynamic Degradation and Fatigue Damage of Degradable Zinc Alloy Stents
Current research on the fatigue properties of degradable zinc alloy stents has not yet considered the issue of the fatigue life changing with material properties during the dynamic degradation process. Therefore, in this paper, we established a fatigue damage algorithm to study the fatigue problem affected by the changing of material properties during the dynamic degradation process of the stent under the action of pulsating cyclic loading. Three models: the dynamic degradation model, the dynamic degradation model under pulsating cyclic loading, and the coupled model of fatigue damage and dynamic degradation, were developed to verify the effect of fatigue damage on stent life. The results show that fatigue damage leads to a deeper degree of inhomogeneous degradation of the stent, which affects the service life of the stent. Fatigue damage is a factor that cannot be ignored. Therefore, when studying the mechanical properties and lifetime of degradable stents, incorporating fatigue damage into the study can help more accurately assess the lifetime of the stents.
- 15 November 2023
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 14 (11) , 547
Open AccessNumerical Simulation of Dynamic Degradation and Fatigue Damage of Degradable Zinc Alloy Stents
Current research on the fatigue properties of degradable zinc alloy stents has not yet considered the issue of the fatigue life changing with material properties during the dynamic degradation process. Therefore, in this paper, we established a fatigue damage algorithm to study the fatigue problem affected by the changing of material properties during the dynamic degradation process of the stent under the action of pulsating cyclic loading. Three models: the dynamic degradation model, the dynamic degradation model under pulsating cyclic loading, and the coupled model of fatigue damage and dynamic degradation, were developed to verify the effect of fatigue damage on stent life. The results show that fatigue damage leads to a deeper degree of inhomogeneous degradation of the stent, which affects the service life of the stent. Fatigue damage is a factor that cannot be ignored. Therefore, when studying the mechanical properties and lifetime of degradable stents, incorporating fatigue damage into the study can help more accurately assess the lifetime of the stents.
- Open Access
- 14 September 2022
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 13 (3) , 152
Finite Element Analysis of the Non-Uniform Degradation of Biodegradable Vascular Stents
Most of the studies on the finite element analysis (FEA) of biodegradable vascular stents (BVSs) during the degradation process have limited the accuracy of the simulation results due to the application of the uniform degradation model. This paper aims to establish an FEA model for the non-uniform degradation of BVSs by considering factors such as the dynamic changes of the corrosion properties and material properties of the element, as well as the pitting corrosion and stress corrosion. The results revealed that adjusting the corrosion rate according to the number of exposed surfaces of the element and reducing the stress threshold according to the corrosion status accelerates the degradation time of BVSs by 26% and 25%, respectively, compared with the uniform degradation model. The addition of the pitting model reduces the service life of the BVSs by up to 12%. The effective support of the stent to the vessel could reach at least 60% of the treatment effect before the vessel collapsed. These data indicate that the proposed non-uniform degradation model of BVSs with multiple factors produces different phenomena compared with the commonly used models and make the numerical simulation results more consistent with the real degradation scenario.
- 14 September 2022
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 13 (3) , 152
Open AccessFinite Element Analysis of the Non-Uniform Degradation of Biodegradable Vascular Stents
Most of the studies on the finite element analysis (FEA) of biodegradable vascular stents (BVSs) during the degradation process have limited the accuracy of the simulation results due to the application of the uniform degradation model. This paper aims to establish an FEA model for the non-uniform degradation of BVSs by considering factors such as the dynamic changes of the corrosion properties and material properties of the element, as well as the pitting corrosion and stress corrosion. The results revealed that adjusting the corrosion rate according to the number of exposed surfaces of the element and reducing the stress threshold according to the corrosion status accelerates the degradation time of BVSs by 26% and 25%, respectively, compared with the uniform degradation model. The addition of the pitting model reduces the service life of the BVSs by up to 12%. The effective support of the stent to the vessel could reach at least 60% of the treatment effect before the vessel collapsed. These data indicate that the proposed non-uniform degradation model of BVSs with multiple factors produces different phenomena compared with the commonly used models and make the numerical simulation results more consistent with the real degradation scenario.