Shorouq Majid Abass
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shorouq Majid Abass has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Aseel Mohammed Al-Khafaji
Department of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq
4 shared publications - Bayan S. Khalaf
Prosthetic Departments, College of dentistry, University of Baghdad, Baghdad, Iraq
4 shared publications Tameem K. Jassim
Department of Prosthodontics, Mustansiriyah Unversity, College of Dentistry, Baghdad
2 shared publications- Ali Hebeish
National Research Centre, Textile Research Division, Dokki, Cairo, Egypt
1 shared publication Bayan Saleem Khalaf
University of Baghdad, College of Dentistry, Department of Prosthodontics. Baghdad, Iraq
1 shared publicationJasim Zaid Ma
Department of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, IRQ
1 shared publication
Latest Publications
- Open Access
- 15 June 2026
- Published by MDPI AG in Prosthesis
- Vol. 8 (6) , 59
Synergistic Effect of White Vinegar-Sodium Bicarbonate Mixture on Candida albicans and Heat-Cured Acrylic Denture Base Material Properties
Background/Objectives: Denture disinfection is a crucial step in reducing microbial colonization and the risk of denture stomatitis, as well as contributing to patient health and denture longevity; thus, it was obligatory to select an effective cleanser without undesirable impact on properties of acrylic denture base material. This study aimed to assess the synergistic effect of white vinegar and sodium bicarbonate (WVSB) mixture on Candida albicans by means of colony forming unit (CFU) and adhesion assays, as well as the surface roughness and flexural strength of heat-cured acrylic denture base material after being immersed in the WVSB mixture. Methods: In total, 200 specimens of heat-cured acrylic resin were prepared: 50 per each test, 5 per each group. They were divided into ten groups; distilled water (negative control), a Corega denture cleanser tablet soaked for 5 min (positive control), and four concentrations (2%, 3%, 4% and 5%) of WVSB mixture were made and examined for (5 and 10 min) immersion durations. Statistical analysis was performed by using Welch’s ANOVA alongside Games–Howell post hoc tests for CFU assay and one-way ANOVA along with Tukey HSD post hoc tests for remaining tests. A p < 0.05 was considered significant in all experiments. Results: The results for the CFU, adhesion and surface roughness tests showed that the WVSB mixture demonstrated a statistically significant difference in most test groups compared to the negative control group, while the flexural strength test showed a statistically non-significant difference. Conclusions: The WVSB mixture showed concentration and time-dependent antifungal effects against C. albicans, with increased surface roughness and no negative effect on the flexural strength of heat-cure acrylic.
- 15 June 2026
- Published by MDPI AG in Prosthesis
- Vol. 8 (6) , 59
Open AccessSynergistic Effect of White Vinegar-Sodium Bicarbonate Mixture on Candida albicans and Heat-Cured Acrylic Denture Base Material Properties
Background/Objectives: Denture disinfection is a crucial step in reducing microbial colonization and the risk of denture stomatitis, as well as contributing to patient health and denture longevity; thus, it was obligatory to select an effective cleanser without undesirable impact on properties of acrylic denture base material. This study aimed to assess the synergistic effect of white vinegar and sodium bicarbonate (WVSB) mixture on Candida albicans by means of colony forming unit (CFU) and adhesion assays, as well as the surface roughness and flexural strength of heat-cured acrylic denture base material after being immersed in the WVSB mixture. Methods: In total, 200 specimens of heat-cured acrylic resin were prepared: 50 per each test, 5 per each group. They were divided into ten groups; distilled water (negative control), a Corega denture cleanser tablet soaked for 5 min (positive control), and four concentrations (2%, 3%, 4% and 5%) of WVSB mixture were made and examined for (5 and 10 min) immersion durations. Statistical analysis was performed by using Welch’s ANOVA alongside Games–Howell post hoc tests for CFU assay and one-way ANOVA along with Tukey HSD post hoc tests for remaining tests. A p < 0.05 was considered significant in all experiments. Results: The results for the CFU, adhesion and surface roughness tests showed that the WVSB mixture demonstrated a statistically significant difference in most test groups compared to the negative control group, while the flexural strength test showed a statistically non-significant difference. Conclusions: The WVSB mixture showed concentration and time-dependent antifungal effects against C. albicans, with increased surface roughness and no negative effect on the flexural strength of heat-cure acrylic.
- Open Access
- 8 May 2025
- Published by MDPI AG in Prosthesis
- Vol. 7 (3) , 48
Cordia Myxa Fruit Extract Antibacterial Efficacy and Its Effect on the Surface Roughness of Heat-Cured Acrylic Denture Base Material
Background/Objectives: Using chemical disinfectants to clean the base of heat-cured acrylic dentures has several negative effects, including toxicity. On the other hand, therapeutic herbs have fewer adverse effects. This study intended to determine how the antibacterial efficacy and the surface roughness of the heat-cured acrylic material used to fabricate dentures were affected by the use of Cordia myxa fruit (CMF) extract as a disinfection solution for dentures using the immersion technique. Methods: Heat-cured acrylic specimens were prepared (N = 110; 55 specimens) for each test; each group contained five specimens. Three CMF extract concentrations (50, 100, and 150 mg/mL) were made and examined for three immersion times (5, 10, and 15 min). The results were compared to the first control group, which used distilled water, and the second group, which used 2% glutaraldehyde for ten minutes, in accordance with the guidelines. One way analysis of variance ANOVA and Games–Howell post hoc test were employed in SPSS (Statistical Package for the Social Sciences) program for statistical analysis. Results: The results for the antibacterial test revealed that CMF solutions had a statistically significant difference in all test groups in comparison with the first control group and non-significant differences with (H p = 0.92; J p = 0.278; K p = 0.303) groups in comparison with the second control group (Glutaraldehyde 2%). For the surface roughness test, the effect was not statistically significant for all groups compared to the first and second control groups. Conclusions: It can be concluded that immersing the heat-cure acrylic samples in a solution of 100 mg/mL CMF extract for 15 min, and 150 mg/mL for 10 and 15 min, has an antibacterial effect similar to that of the Glutaraldehyde 2% antiseptic and no negative effect on surface roughness.
- 8 May 2025
- Published by MDPI AG in Prosthesis
- Vol. 7 (3) , 48
Open AccessCordia Myxa Fruit Extract Antibacterial Efficacy and Its Effect on the Surface Roughness of Heat-Cured Acrylic Denture Base Material
Background/Objectives: Using chemical disinfectants to clean the base of heat-cured acrylic dentures has several negative effects, including toxicity. On the other hand, therapeutic herbs have fewer adverse effects. This study intended to determine how the antibacterial efficacy and the surface roughness of the heat-cured acrylic material used to fabricate dentures were affected by the use of Cordia myxa fruit (CMF) extract as a disinfection solution for dentures using the immersion technique. Methods: Heat-cured acrylic specimens were prepared (N = 110; 55 specimens) for each test; each group contained five specimens. Three CMF extract concentrations (50, 100, and 150 mg/mL) were made and examined for three immersion times (5, 10, and 15 min). The results were compared to the first control group, which used distilled water, and the second group, which used 2% glutaraldehyde for ten minutes, in accordance with the guidelines. One way analysis of variance ANOVA and Games–Howell post hoc test were employed in SPSS (Statistical Package for the Social Sciences) program for statistical analysis. Results: The results for the antibacterial test revealed that CMF solutions had a statistically significant difference in all test groups in comparison with the first control group and non-significant differences with (H p = 0.92; J p = 0.278; K p = 0.303) groups in comparison with the second control group (Glutaraldehyde 2%). For the surface roughness test, the effect was not statistically significant for all groups compared to the first and second control groups. Conclusions: It can be concluded that immersing the heat-cure acrylic samples in a solution of 100 mg/mL CMF extract for 15 min, and 150 mg/mL for 10 and 15 min, has an antibacterial effect similar to that of the Glutaraldehyde 2% antiseptic and no negative effect on surface roughness.
- Open Access
- 1 January 2025
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 28 (1)
Actual dimensions, design, and fabrication of readymade posterior palatal seal for completely edentulous patients
Objective: To obtain the actual measurements of the posterior palatal seal area to assist in designing and fabricating a readymade posterior palatal seal for maxillary complete dentures. Material and Methods: Twentyfive completely edentulous patients were included in the present investigation, 13 females and 12 males with a mean age of 57.5 years. After making the definitive impressions and construction of the definitive casts, threedimensional digital models of the maxillary completely edentulous arches were obtained with an intraoral scanner. The actual curved and linear line measurements of the posterior palatal seal area on the digital maxillary models were acquired with MEDIT LINK 3.0.4 software package. Results: There was a higher mean for the actual curved dimensions than the linear line dimensions. The design and fabrication of a readymade posterior palatal seal were accomplished depending on the percentage of difference (11.17%). Conclusion: The difference between the actual and the linear line measurements of posterior palatal seal area was used for designing and fabricating a readymade posterior palatal seal that could be used in the manufacturing of the complete denture. KEYWORDS Complete, denture; Dentists; Denture retention; Edentulous.
- 1 January 2025
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 28 (1)
Open AccessActual dimensions, design, and fabrication of readymade posterior palatal seal for completely edentulous patients
Objective: To obtain the actual measurements of the posterior palatal seal area to assist in designing and fabricating a readymade posterior palatal seal for maxillary complete dentures. Material and Methods: Twentyfive completely edentulous patients were included in the present investigation, 13 females and 12 males with a mean age of 57.5 years. After making the definitive impressions and construction of the definitive casts, threedimensional digital models of the maxillary completely edentulous arches were obtained with an intraoral scanner. The actual curved and linear line measurements of the posterior palatal seal area on the digital maxillary models were acquired with MEDIT LINK 3.0.4 software package. Results: There was a higher mean for the actual curved dimensions than the linear line dimensions. The design and fabrication of a readymade posterior palatal seal were accomplished depending on the percentage of difference (11.17%). Conclusion: The difference between the actual and the linear line measurements of posterior palatal seal area was used for designing and fabricating a readymade posterior palatal seal that could be used in the manufacturing of the complete denture. KEYWORDS Complete, denture; Dentists; Denture retention; Edentulous.
- Open Access
- 29 November 2024
- Published by F1000 Research Ltd in F1000Research
- Vol. 13, 1006
Posterior palatal seal recording: fact and reasons among Iraqi dentists
Backgrounds The retention of the maxillary complete denture may be influenced by adequate recording in the patient’s mouth, marking, and carving of the post-dam on the maxillary cast. Failure to do so may lead to loss of retention. Successful denture construction with patient’s comfort could be achieved by effective methods of recording, marking, and carving of the post-dam. The aim of the study was to assess Iraqi dentists in their knowledge and application of the post-dam in maxillary complete dentures. Methods Questionnaires were distributed randomly through online Google Forms and 118 Iraqi dentists with different academic degree participated in the study. A multinomial logistic regression model was also used to assess the nominal outcome variables. Results A High percentage of 90.7% of Iraqi dentists with different academic degree stated that they had the knowledge about the vibrating lines and their location and 84.7% stated that they mark the post-dam on the master cast, while 15.3% stated that the dental technician marks it. More the half (52.5%) of the participants carved the post-dam, while 47.5% of the participants stated that the dental technician did it. For participants not marking the post-dam, 30.5% of the participants stated they depend on the dental technician in marking and/or carve the post-dam, while the fear of denture failure and loss of retention was observed in 25.4% of the participants, followed by 24.6% of participants forgetting to carve, 10.2% of participants had no information about carving, and 9.3% participants found it was difficult to carve. Conclusions Within the limitations of the study, most Iraqi dentists with different academic degree stated that they had the knowledge on the location of vibrating lines. However, recording and carving the post-dam was influenced by the dentist’s personal preference and their dependency on the dental technician.
- 29 November 2024
- Published by F1000 Research Ltd in F1000Research
- Vol. 13, 1006
Open AccessPosterior palatal seal recording: fact and reasons among Iraqi dentists
Backgrounds The retention of the maxillary complete denture may be influenced by adequate recording in the patient’s mouth, marking, and carving of the post-dam on the maxillary cast. Failure to do so may lead to loss of retention. Successful denture construction with patient’s comfort could be achieved by effective methods of recording, marking, and carving of the post-dam. The aim of the study was to assess Iraqi dentists in their knowledge and application of the post-dam in maxillary complete dentures. Methods Questionnaires were distributed randomly through online Google Forms and 118 Iraqi dentists with different academic degree participated in the study. A multinomial logistic regression model was also used to assess the nominal outcome variables. Results A High percentage of 90.7% of Iraqi dentists with different academic degree stated that they had the knowledge about the vibrating lines and their location and 84.7% stated that they mark the post-dam on the master cast, while 15.3% stated that the dental technician marks it. More the half (52.5%) of the participants carved the post-dam, while 47.5% of the participants stated that the dental technician did it. For participants not marking the post-dam, 30.5% of the participants stated they depend on the dental technician in marking and/or carve the post-dam, while the fear of denture failure and loss of retention was observed in 25.4% of the participants, followed by 24.6% of participants forgetting to carve, 10.2% of participants had no information about carving, and 9.3% participants found it was difficult to carve. Conclusions Within the limitations of the study, most Iraqi dentists with different academic degree stated that they had the knowledge on the location of vibrating lines. However, recording and carving the post-dam was influenced by the dentist’s personal preference and their dependency on the dental technician.
- Open Access
- 25 September 2024
- Published by University Library System, University of Pittsburgh in Dentistry 3000
- Vol. 12 (2)
Antimicrobial Efficiency of Hypochlorous Acid Incorporation and its Effect on Surface Properties of Irreversible Hydrocolloid Materials
Objective: Conventional approaches for disinfection, including spraying and immersion, resulted in only surface disinfection of impressions. As a result, self-disinfecting impression materials incorporated with antimicrobial compounds require more extensive studies. The incorporation of a disinfectant into irreversible hydrocolloid impression materials could eliminate the need for the disinfection step by conventional approaches, including spraying and immersion which only result in surface disinfection of impressions. The study was aimed to investigate the effect of incorporation of hypochlorous acid in irreversible hydrocolloid materials on antimicrobial efficiency, detail reproduction, and dimensional stability. Materials and Methods: Hypochlorous acid (HOCl) was used in two concentrations, 100 ppm and 200 ppm, and mixed with alginate powder to compare with the control group (distilled water mixed with alginate). Candida albicans, Staphylococcus aureus, and Pseudomonas aeruginosawere chosen for assessing the antimicrobial activity with the disk diffusion test. In addition, the dimensional stability and reproduction of details were tested. Results: The results revealed that both HOCl concentrations of 100 ppm and 200 ppm imposed significant antimicrobial activity against all three tested microorganisms. There was no significant difference regarding reproduction of details, but the addition of the antimicrobial had a significant adverse effect on the alginate’s dimensional stability. Conclusion: It may be concluded that the incorporation of HOCL into irreversible hydrocolloid impression material resulted in an impression with antimicrobial activity. In addition, there was no effect on the impression materials ability to reproduce surface details, but the antimicrobial addition may affect its dimensional stability.
- 25 September 2024
- Published by University Library System, University of Pittsburgh in Dentistry 3000
- Vol. 12 (2)
Open AccessAntimicrobial Efficiency of Hypochlorous Acid Incorporation and its Effect on Surface Properties of Irreversible Hydrocolloid Materials
Objective: Conventional approaches for disinfection, including spraying and immersion, resulted in only surface disinfection of impressions. As a result, self-disinfecting impression materials incorporated with antimicrobial compounds require more extensive studies. The incorporation of a disinfectant into irreversible hydrocolloid impression materials could eliminate the need for the disinfection step by conventional approaches, including spraying and immersion which only result in surface disinfection of impressions. The study was aimed to investigate the effect of incorporation of hypochlorous acid in irreversible hydrocolloid materials on antimicrobial efficiency, detail reproduction, and dimensional stability. Materials and Methods: Hypochlorous acid (HOCl) was used in two concentrations, 100 ppm and 200 ppm, and mixed with alginate powder to compare with the control group (distilled water mixed with alginate). Candida albicans, Staphylococcus aureus, and Pseudomonas aeruginosawere chosen for assessing the antimicrobial activity with the disk diffusion test. In addition, the dimensional stability and reproduction of details were tested. Results: The results revealed that both HOCl concentrations of 100 ppm and 200 ppm imposed significant antimicrobial activity against all three tested microorganisms. There was no significant difference regarding reproduction of details, but the addition of the antimicrobial had a significant adverse effect on the alginate’s dimensional stability. Conclusion: It may be concluded that the incorporation of HOCL into irreversible hydrocolloid impression material resulted in an impression with antimicrobial activity. In addition, there was no effect on the impression materials ability to reproduce surface details, but the antimicrobial addition may affect its dimensional stability.
- Open Access
- 4 September 2024
- Published by F1000 Research Ltd in F1000Research
- Vol. 13, 1006
Posterior palatal seal recording: fact and reasons among Iraqi dentists
* Backgrounds The retention of the maxillary complete denture may be influenced by adequate recording in the patient’s mouth, marking, and carving of the post-dam on the maxillary cast. Failure to do so may lead to loss of retention. Successful denture construction with patient’s comfort could be achieved by effective methods of recording, marking, and carving of the post-dam. The aim of the study was to assess Iraqi dentists in their knowledge and application of the post-dam in maxillary complete dentures. Methods Questionnaires were distributed randomly through online Google Forms and 118 Iraqi dentists with different academic degree participated in the study. A multinomial logistic regression model was also used to assess the nominal outcome variables. Results A High percentage of 90.7% of Iraqi dentists with different academic degree stated that they had the knowledge about the vibrating lines and their location and 84.7% stated that they mark the post-dam on the master cast, while 15.3% stated that the dental technician marks it. More the half (52.5%) of the participants carved the post-dam, while 47.5% of the participants stated that the dental technician did it. For participants not marking the post-dam, 30.5% of the participants stated they depend on the dental technician in marking and/or carve the post-dam, while the fear of denture failure and loss of retention was observed in 25.4% of the participants, followed by 24.6% of participants forgetting to carve, 10.2% of participants had no information about carving, and 9.3% participants found it was difficult to carve. Conclusions Within the limitations of the study, most Iraqi dentists with different academic degree stated that they had the knowledge on the location of vibrating lines. However, recording and carving the post-dam was influenced by the dentist’s personal preference and their dependency on the dental technician.
- 4 September 2024
- Published by F1000 Research Ltd in F1000Research
- Vol. 13, 1006
Open AccessPosterior palatal seal recording: fact and reasons among Iraqi dentists
* Backgrounds The retention of the maxillary complete denture may be influenced by adequate recording in the patient’s mouth, marking, and carving of the post-dam on the maxillary cast. Failure to do so may lead to loss of retention. Successful denture construction with patient’s comfort could be achieved by effective methods of recording, marking, and carving of the post-dam. The aim of the study was to assess Iraqi dentists in their knowledge and application of the post-dam in maxillary complete dentures. Methods Questionnaires were distributed randomly through online Google Forms and 118 Iraqi dentists with different academic degree participated in the study. A multinomial logistic regression model was also used to assess the nominal outcome variables. Results A High percentage of 90.7% of Iraqi dentists with different academic degree stated that they had the knowledge about the vibrating lines and their location and 84.7% stated that they mark the post-dam on the master cast, while 15.3% stated that the dental technician marks it. More the half (52.5%) of the participants carved the post-dam, while 47.5% of the participants stated that the dental technician did it. For participants not marking the post-dam, 30.5% of the participants stated they depend on the dental technician in marking and/or carve the post-dam, while the fear of denture failure and loss of retention was observed in 25.4% of the participants, followed by 24.6% of participants forgetting to carve, 10.2% of participants had no information about carving, and 9.3% participants found it was difficult to carve. Conclusions Within the limitations of the study, most Iraqi dentists with different academic degree stated that they had the knowledge on the location of vibrating lines. However, recording and carving the post-dam was influenced by the dentist’s personal preference and their dependency on the dental technician.
- Open Access
- 20 March 2024
- Published by F1000 Research Ltd in F1000Research
- Vol. 13, 195
Effect of propolis on the mechanophysical properties of addition silicon dental impression material
Background Dental impressions should be disinfected to stop the transmission of germs among dental workers since they provide a risk of diseases. The aim of this study was to examine the effects of two disinfectants (16 mg/ml propolis and 5.25% sodium hypochlorite) on the detail reproduction, linear dimensional change, compatibility with gypsum products, wettability, and surface roughness of addition silicon material. Methods Ninety specimens were created using Addition silicon impression material, and they were then divided into three groups at random. Ten specimens from each test group were used in each test. Utilizing apparatus made in accordance with ISO 4823:2015, detail reproduction, linear dimensional change, and compatibility with gypsum products are assessed. A digital Profilometer was uutilized to evaluate surface roughness, and a Goniometer was utilized to evaluate wettability by taking the contact angle. Before testing, the specimens were immersed for 10 minutes each in two disinfection solutions: 16 mg/ml propolis and 5.25% NaOCL. The control group received no disinfection. One-way ANOVA tests and the Kruskal-Wallis test, which was statistically significant at a level of p 0.05, were used to examine the data. Results Comparing the linear dimensional change, surface roughness, and wettability of Addition silicon specimens immersed in 16 mg/ml propolis, 5.25% NaOCL, or the control group demonstrated statistically significant differences (p< 0.05), while details reproduction and compatibility with gypsum revealed statistically no significant differences (p > 0.05). Conclusion Within the parameters of this study, the addition silicon can be immersed in 16 mg/ml propolis for 10 min. to disinfect it without compromising its dimensional accuracy, detail reproduction, compatibility with gypsum products, surface roughness, or wettability.
- 20 March 2024
- Published by F1000 Research Ltd in F1000Research
- Vol. 13, 195
Open AccessEffect of propolis on the mechanophysical properties of addition silicon dental impression material
Background Dental impressions should be disinfected to stop the transmission of germs among dental workers since they provide a risk of diseases. The aim of this study was to examine the effects of two disinfectants (16 mg/ml propolis and 5.25% sodium hypochlorite) on the detail reproduction, linear dimensional change, compatibility with gypsum products, wettability, and surface roughness of addition silicon material. Methods Ninety specimens were created using Addition silicon impression material, and they were then divided into three groups at random. Ten specimens from each test group were used in each test. Utilizing apparatus made in accordance with ISO 4823:2015, detail reproduction, linear dimensional change, and compatibility with gypsum products are assessed. A digital Profilometer was uutilized to evaluate surface roughness, and a Goniometer was utilized to evaluate wettability by taking the contact angle. Before testing, the specimens were immersed for 10 minutes each in two disinfection solutions: 16 mg/ml propolis and 5.25% NaOCL. The control group received no disinfection. One-way ANOVA tests and the Kruskal-Wallis test, which was statistically significant at a level of p 0.05, were used to examine the data. Results Comparing the linear dimensional change, surface roughness, and wettability of Addition silicon specimens immersed in 16 mg/ml propolis, 5.25% NaOCL, or the control group demonstrated statistically significant differences (p< 0.05), while details reproduction and compatibility with gypsum revealed statistically no significant differences (p > 0.05). Conclusion Within the parameters of this study, the addition silicon can be immersed in 16 mg/ml propolis for 10 min. to disinfect it without compromising its dimensional accuracy, detail reproduction, compatibility with gypsum products, surface roughness, or wettability.
- Open Access
- 14 November 2023
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-7
Antimicrobial Efficiency of Hypochlorous Acid and Its Effect on Some Properties of Alginate Impression Material
Dental clinicians and professionals need an affordable, nontoxic, and effective disinfectant against infectious microorganisms when dealing with the contaminated dental impressions. This study evaluated the efficiency of hypochlorous acid (HOCl) as an antimicrobial disinfectant by spraying technique for the alginate impression materials, compared with sodium hypochlorite, and its effect on dimensional stability and reproduction of details. HOCl with a concentration of 200ppm for 5 and 10min was compared with the control group (no treatment) as a negative control and with sodium hypochlorite ( 0.5) as a positive control. Candida albicans, Staphylococcus aureus, and Pseudomonas aeruginosa were selected to assess the antimicrobial activity with the colony forming unit test in addition to the dimensional stability and reproduction of details tests. The results revealed that HOCl had significant antimicrobial activity against all tested microorganisms and experimental time. Interestingly, HOCl showed no impact on the dimensional stability of alginate impression material. HOCl could be an effective antimicrobial agent for alginate impression material without interfering with their surface details and dimensional stability.
- 14 November 2023
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-7
Open AccessAntimicrobial Efficiency of Hypochlorous Acid and Its Effect on Some Properties of Alginate Impression Material
Dental clinicians and professionals need an affordable, nontoxic, and effective disinfectant against infectious microorganisms when dealing with the contaminated dental impressions. This study evaluated the efficiency of hypochlorous acid (HOCl) as an antimicrobial disinfectant by spraying technique for the alginate impression materials, compared with sodium hypochlorite, and its effect on dimensional stability and reproduction of details. HOCl with a concentration of 200ppm for 5 and 10min was compared with the control group (no treatment) as a negative control and with sodium hypochlorite ( 0.5) as a positive control. Candida albicans, Staphylococcus aureus, and Pseudomonas aeruginosa were selected to assess the antimicrobial activity with the colony forming unit test in addition to the dimensional stability and reproduction of details tests. The results revealed that HOCl had significant antimicrobial activity against all tested microorganisms and experimental time. Interestingly, HOCl showed no impact on the dimensional stability of alginate impression material. HOCl could be an effective antimicrobial agent for alginate impression material without interfering with their surface details and dimensional stability.
- Open Access
- 30 November 2022
- Published by Springer Nature in Cureus
- Vol. 14 (11) , e32061
The Effect of Hypochlorous Acid Disinfectant on the Reproduction of Details and Surface Hardness of Type III Dental Stone
Gypsum products have been used for many years in dentistry. They are used to make casts that are used in different dental laboratory procedures. It is considered a source of contamination because it comes in contact with blood and saliva that are found on dental impressions. Because it is difficult to make sure that every impression brought to the dental laboratory has been cleaned and because cleaning impressions is a complicated process that can lead to problems because of the way impression materials are made, cleaning the cast has become a key part of preventing infections. For this study, we used two ways (immersion and spray) to apply a hypochlorous acid (HOCl) disinfectant solution to type III dental stone to see how they affected the stone's surface hardness and its ability to show surface details accurately. A total of 100 samples of type III dental stone, 50 samples for each test, which include the reproduction of detail test and surface hardness test, were prepared and randomly divided into five groups, 10 samples for each test group, which include group A (control), group B (immersion in 200 ppm HOCl disinfectant for five minutes), group C (spraying with 200 ppm HOCl disinfectant for five minutes), group D (immersion in 0.6% sodium hypochlorite (NaOCl) disinfectant for five minutes), and group E (spraying with 0.6% NaOCl disinfectant for five minutes). The results showed that all the samples had met the reproduction of detail test requirement after disinfection with HOCl, while a significant reduction in the surface hardness of type III stone samples was also shown. The less undesirable effects of HOCl disinfectant solution on the surface hardness of type III dental stone when compared to sodium hypochlorite, as well as the absence of adverse effects on detail reproduction, made the HOCl disinfectant solution a good choice for dentists and dental laboratory personnel for cast disinfection and contamination control.
- 30 November 2022
- Published by Springer Nature in Cureus
- Vol. 14 (11) , e32061
Open AccessThe Effect of Hypochlorous Acid Disinfectant on the Reproduction of Details and Surface Hardness of Type III Dental Stone
Gypsum products have been used for many years in dentistry. They are used to make casts that are used in different dental laboratory procedures. It is considered a source of contamination because it comes in contact with blood and saliva that are found on dental impressions. Because it is difficult to make sure that every impression brought to the dental laboratory has been cleaned and because cleaning impressions is a complicated process that can lead to problems because of the way impression materials are made, cleaning the cast has become a key part of preventing infections. For this study, we used two ways (immersion and spray) to apply a hypochlorous acid (HOCl) disinfectant solution to type III dental stone to see how they affected the stone's surface hardness and its ability to show surface details accurately. A total of 100 samples of type III dental stone, 50 samples for each test, which include the reproduction of detail test and surface hardness test, were prepared and randomly divided into five groups, 10 samples for each test group, which include group A (control), group B (immersion in 200 ppm HOCl disinfectant for five minutes), group C (spraying with 200 ppm HOCl disinfectant for five minutes), group D (immersion in 0.6% sodium hypochlorite (NaOCl) disinfectant for five minutes), and group E (spraying with 0.6% NaOCl disinfectant for five minutes). The results showed that all the samples had met the reproduction of detail test requirement after disinfection with HOCl, while a significant reduction in the surface hardness of type III stone samples was also shown. The less undesirable effects of HOCl disinfectant solution on the surface hardness of type III dental stone when compared to sodium hypochlorite, as well as the absence of adverse effects on detail reproduction, made the HOCl disinfectant solution a good choice for dentists and dental laboratory personnel for cast disinfection and contamination control.
- 1 May 2006
- Published by Emerald Publishing in Research Journal of Textile and Apparel
- Vol. 10 (2) , 43-57
No-Salt Dyeing Behaviour of Cationized Linen Fabrics
Linen fabrics were cationized using 3-chloro-2-hydroxypropyl trimethyl ammonium chloride in alkaline medium. The cationized linen fabrics were dyed independently, with different dyestuffs, namely reactive, direct and acid dyes in absence of salt (no-salt dyed). Factors affecting the nosalt dyeing process of cationized linen fabrics were investigated. These factors included dye concentration, pH of the dyeing bath, dyeing temperature and time as well as the chemical nature of the dyes used. The dyed samples were monitored for color strength (K/S) after soaping and after DMF extraction as well as fastness properties. It was found that for all dyestuffs used, the magnitude of K/S of the dyed samples depends on the nature of the dyes and the conditions used in each case. It was also seen that for no-salt dyeing of cationized linen fabrics, the maximum K/S was achieved at dye shade 2.5 % (ows) and dye bath’s pH 7-9, at 60°C for 20 minutes. In addition to this, the color strength was much higher in case of cationized and no-salt dyed samples compared with the uncationized and traditionally salt-dyed linen fabrics; meanwhile, the overall fastness properties were comparable. Microscopic examination of the cationized and no-salt dyed linen fabrics showed an excellent dye penetration and no evidence for the ring dye phenomena was observed.
- 1 May 2006
- Published by Emerald Publishing in Research Journal of Textile and Apparel
- Vol. 10 (2) , 43-57
No-Salt Dyeing Behaviour of Cationized Linen Fabrics
Linen fabrics were cationized using 3-chloro-2-hydroxypropyl trimethyl ammonium chloride in alkaline medium. The cationized linen fabrics were dyed independently, with different dyestuffs, namely reactive, direct and acid dyes in absence of salt (no-salt dyed). Factors affecting the nosalt dyeing process of cationized linen fabrics were investigated. These factors included dye concentration, pH of the dyeing bath, dyeing temperature and time as well as the chemical nature of the dyes used. The dyed samples were monitored for color strength (K/S) after soaping and after DMF extraction as well as fastness properties. It was found that for all dyestuffs used, the magnitude of K/S of the dyed samples depends on the nature of the dyes and the conditions used in each case. It was also seen that for no-salt dyeing of cationized linen fabrics, the maximum K/S was achieved at dye shade 2.5 % (ows) and dye bath’s pH 7-9, at 60°C for 20 minutes. In addition to this, the color strength was much higher in case of cationized and no-salt dyed samples compared with the uncationized and traditionally salt-dyed linen fabrics; meanwhile, the overall fastness properties were comparable. Microscopic examination of the cationized and no-salt dyed linen fabrics showed an excellent dye penetration and no evidence for the ring dye phenomena was observed.