Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dulip Madurasinghe has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • Ganesh Kumar Venayagamoorthy

    Holcombe Department of Electrical and Computer Engineering, Real-Time Power and Intelligent Systems Laboratory, Clemson University, Clemson, SC, USA

    4 shared publications
  • Ganesh K. Venayagamoorthy

    Real-Time Power and Intelligent Systems Laboratory, Clemson University, Clemson, SC, USA

    3 shared publications
  • Paranietharan Arunagirinathan

    Real-Time Power and Intelligent Systems Laboratory, Clemson University, Clemson, SC, USA

    2 shared publications

Latest Publications

  • Open Access

    Distributed Dynamic Security Assessment for Modern Power System Operational Situational Awareness

    by Dulip Madurasinghe, Ganesh Kumar Venayagamoorthy

    The complexity of the power system has increased due to recent grid modernization and active distribution systems. As a result, monitoring and controlling modern power systems have become challenging. Dynamic security assessment (DSA) in power systems is a critical operational situational awareness (OpSA) tool for the energy control center (ECC). State-of-the-art (SOTA) DSA has been based on traditional state estimation utilizing the supervisory control and data acquisition (SCADA) / phasor measurement units (PMU) and transmission network topology processing (TNTP) based on SCADA monitoring of relay signals (TNTP-SMRS). Due to the slow data rates of SCADA, these applications cannot efficiently support an online DSA tool. Furthermore, an inaccurate network model based on TNTP-SMRS can lead to erroneous DSA. In this paper, a distributed dynamic security assessment (D-DSA) based on multi-level distributed linear state estimation (D-LSE) and efficient and reliable hierarchical transmission network topology processing utilizing synchrophasor network (H-TNTP-PMU) has been proposed. The tool can be used in real-time operation at the ECC of modern power systems. D-DSA architecture comprises three levels, namely Level 1 - component level security assessment (substations and transmission lines), Level 2 - area level security assessment, and Level 3 - network level security assessment. D-DSA concurrently evaluates all available substations’ security in the substation security assessment (SSA) and all available transmission lines’ security in the transmission line security assessment (TSA). Under the area security assessment (ASA), all SSA and TSA in each area are separately integrated to assess the area SSI (ASI-SSI) and TSI (ASI-TSI). Subsequently, each area’s area-level security index (ASI) is calculated by fusing ASI-SSI and ASI-TSI. At the network level security assessment, network SSI (NSI-SSI) and TSI (NSI-TSI) are estimated by fusing all ASI-SSIs and ASI-TSI, respectively. Network level security index (NSI) is estimated by fusing the NSI-SSI and NSI-TSI in network security assessment (NSA). Typical results of D-DSA are presented for two test systems, the modified two-area four-machine power system model and the IEEE 68 bus power system model. Results indicate that the proposed D-DSA can complete the assessment accurately at the PMU data frame rate, enabling online security assessment regardless of the network size.


  • Open Access

    Multilevel Distributed Linear State Estimation Integrated with Transmission Network Topology Processing

    by Dulip Madurasinghe, Ganesh Kumar Venayagamoorthy

    State estimation (SE) is an important energy management system application for power system operations. Linear state estimation (LSE) is a variant of SE based on linear relationships between state variables and measurements. LSE estimates system state variables, including bus voltage magnitudes and angles in an electric power transmission network, using a network model derived from the topology processor and measurements. Phasor measurement units (PMUs) enable the implementation of LSE by providing synchronized high-speed measurements. However, as the size of the power system increases, the computational overhead of the state-of-the-art (SOTA) LSE grows exponentially, where the practical implementation of LSE is challenged. This paper presents a distributed linear state estimation (D-LSE) at the substation and area levels using a hierarchical transmission network topology processor (H-TNTP). The proposed substation-level and area-level D-LSE can efficiently and accurately estimate system state variables at the PMU rate, thus enhancing the estimation reliability and efficiency of modern power systems. Network-level LSE has been integrated with H-TNTP based on PMU measurements, thus enhancing the SOTA LSE and providing redundancy to substation-level and area-level D-LSE. The implementations of D-LSE and enhanced LSE have been investigated for two benchmark power systems, a modified two-area four-machine power system and the IEEE 68 bus power system, on a real-time digital simulator. The typical results indicate that the proposed multilevel D-LSE is efficient, resilient, and robust for topology changes, bad data, and noisy measurements compared to the SOTA LSE.


  • Open Access

    An Efficient and Reliable Electric Power Transmission Network Topology Processing

    by Dulip Madurasinghe, Ganesh Kumar Venayagamoorthy

    The modern bulk power system operation is complex and dynamic, with rapidly increasing inverter-based resources and active distribution systems. Therefore, high-speed monitoring is required to operate the power system reliably and efficiently. Transmission network topology processing (TNTP) is vital in power system control. Today’s TNTP is based on supervisory control and data acquisition (SCADA) system monitoring of relay signals (SMRS). Due to the slow data communication rate, SMRS cannot efficiently support the modern bulk power system’s energy management system (EMS) functions. In this study, a physics-based hierarchical TNTP (H-TNTP) approach based solely on node voltages and branch currents measurements is proposed. H-TNTP includes the identification of substation configuration. The reliability of the H-TNTP is guaranteed by the design with inherent verification. If required, H-TNTP is capable of operating concurrently with the TNTP-SMRS. A power system with solar photovoltaic (PV) plants is utilized as a test system to illustrate the proposed H-TNTP approach. Results indicate that H-TNTP is fast with synchrophasor measurements. Furthermore, to demonstrate the application of the reliable and fast TNTP approach in EMSs, fast automatic generation control (AGC) during contingencies is studied. Typical results show that fast reconfiguration of AGC modes and dispatch factors leads to better frequency regulation.


  • Open Access

    Identification of Substation Configurations in Modern Power Systems using Artificial Intelligence

    by Dulip Madurasinghe, Ganesh K. Venayagamoorthy

    Power system transmission network topology is utilized in energy management system applications. Substation configurations are fundamental to transmission network topology processing. Modern power systems consisting of renewable energy sources require reliable and fast network topology processing due to the variable nature of wind and solar power plants. Currently used transmission network topology processing, which is based on the relay signals communicated through SCADA is not highly reliable or highly accurate. Substation configuration identification (SCI) for different substation arrangements including main and transfer bus arrangement (MTBA), ring bus arrangement (RBA), and single bus arrangement (SBA) is investigated. Synchrophasor measurement based SCI for functional arrangements (FA) using artificial intelligence (AI) approaches is proposed in this paper. This method improves monitoring FA. Typical results for MTBA, RBA and SBA substation configuration identification is presented. A modified two-area four-machine power system model with two grid connected solar PV plants consisting of MTBA, RBA and SBA is simulated on real-time digital simulator. AI based SCI is shown to accurately identify all possible FAs for the three substation arrangements under any operating condition.


  • Distributed Identification of Power System Network Branch Events

    by Dulip Madurasinghe, Paranietharan Arunagirinathan, Ganesh K. Venayagamoorthy

    Online identification of power system network branches is critical in modern electric power system operation. Availability of phasor measurement units (PMUs) can be used to identify branch events. Due to complexity of the power system, a distributed cellular computational network (CCN) is proposed. Comparison of centralized and distributed neural network based power system network branch events identification is studied. IEEE 12-bus benchmark power system is simulated on real-time digital simulator platform for this study. CCN based distributed neural network approach is computationally efficient compared to centralized approach.

  • LVQ Neural Network for Online Identification of Power System Network Branch Events

    by Dulip Madurasinghe, Ganesh K. Venayagamoorthy

    The transmission network is the backbone of the power system. Fast power system network branch event identification is required to maintain security of the power system. Phasor measurement units (PMUs) provide synchronized voltage and current phasor measurements to a centralized phasor data concentrator (PDC). Thus, PMU measurements can be used for online branch event identification. A fast and efficient approach is required to ease the computational load. Learning vector quantization (LVQ) neural network algorithm is presented in this paper as a solution to identify branch events. The power system is highly distributed. Thus, a cellular computational network (CCN) is utilized to distribute a single large LVQ's computational load. The IEEE 12-bus benchmark power system is used to illustrate the CCN-LVQ approach. The power system is simulated on a realtime digital simulator. CCN-LVQ approach is shown to be fast, efficient and comparatively accurate for transmission network branch event identification.


  • Online Identification of Power System Network Branch Events

    by Dulip Madurasinghe, Paranietharan Arunagirinathan, Ganesh K. Venayagamoorthy

    The electric power grid infrastructure is the most critically important man-made system in use today, particularly since all other infrastructures depend on the reliability of a robust electrical infrastructure. The smart grid transformation enables the real-time situational awareness through synchronized measurements. The communication network capable of bi-directional communication is responsible for the full connectivity of all the measurement and control units. In the power system, the transmission network is the bridge between the bulk generation and distribution system. The reliability of the power system is highly dependent on the successful operation of the geographically distributed transmission network and its components. Power system network branch outages, which may occur due to number of reasons, may result in either partial or complete blackout of the power system. The smart grid is a cyber-physical system. The cyber-physical systems are vulnerable to cyber and physical attacks. In this paper transmission network branch outage identification using phasor measurement units is investigated. Real-time digital simulator based simulation platform has been used. Admittance matrix based approach and neural network approach are investigated and performances evaluated.