Jean-Marie Verilhac
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jean-Marie Verilhac has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- C. Serbutoviez
University Grenoble Alpes,CEA, LITEN,Grenoble,France,38000
2 shared publications - Eric Gros D'Aillon
Grenoble Alpes University, CEA, LETI, DOPT, F38000 Grenoble, France
2 shared publications - Ferdinand Lédée
University Grenoble Alpes, CEA, LITEN, DTNM 1 , FR-38000 Grenoble
2 shared publications - Javier Mayén Guillén
Grenoble Alpes University, CEA, LITEN, DTNM, F38000 Grenoble, France
2 shared publications - Julien Zaccaro
Grenoble Alpes University, CNRS, Grenoble INP, Institut Néel, F38042 Grenoble, France
2 shared publications R. Coppard
CEA-LITEN/PICTIC Grenoble, France
2 shared publications
Latest Publications
- Open Access
- 20 June 2024
- Published by Wiley in Advanced Electronic Materials
- Vol. 10 (11)
Ion Migration and Space‐Charge Zones in Metal Halide Perovskites Through Short‐Circuit Transient Current and Numerical Simulations
The inherent ion migration in metal halide perovskite materials is known to induce deleterious and highly unstable dark currents in X‐ and γ‐ray detectors based on those compounds upon bias application. Dark current slow drift with time is identified as one of the major drawbacks for these devices to satisfy industrial requirements. Because dark current establishes the detectability limit, current evolution, and eventual growth may mask photocurrent signals produced by incoming X‐ray photons. Relevant information for detector assessment is ion‐related parameters such as ion concentration, ion mobility, and ionic space‐charge zones that are eventually built near the outer contacts upon detector biasing. A combined experimental (simple measurement of dark current transients) and 1D numerical simulation method is followed here using single‐crystal and microcrystalline millimeter‐thick methylammonium‐lead bromide that allows extracting ion mobility within the range of µion ≈ 10−7 cm2 V−1 s−1, while ion concentration values approximate Nion ≈ 1015 cm−3, depending on the perovskite crystallinity.
- 20 June 2024
- Published by Wiley in Advanced Electronic Materials
- Vol. 10 (11)
Open AccessIon Migration and Space‐Charge Zones in Metal Halide Perovskites Through Short‐Circuit Transient Current and Numerical Simulations
The inherent ion migration in metal halide perovskite materials is known to induce deleterious and highly unstable dark currents in X‐ and γ‐ray detectors based on those compounds upon bias application. Dark current slow drift with time is identified as one of the major drawbacks for these devices to satisfy industrial requirements. Because dark current establishes the detectability limit, current evolution, and eventual growth may mask photocurrent signals produced by incoming X‐ray photons. Relevant information for detector assessment is ion‐related parameters such as ion concentration, ion mobility, and ionic space‐charge zones that are eventually built near the outer contacts upon detector biasing. A combined experimental (simple measurement of dark current transients) and 1D numerical simulation method is followed here using single‐crystal and microcrystalline millimeter‐thick methylammonium‐lead bromide that allows extracting ion mobility within the range of µion ≈ 10−7 cm2 V−1 s−1, while ion concentration values approximate Nion ≈ 1015 cm−3, depending on the perovskite crystallinity.
- Open Access
- 15 November 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (19)
Evidence for a build-in remnant field in symmetrically contacted MAPbBr3 x-ray detectors
Millimeter-thick methylammonium lead tribromide (MAPbBr3) single crystal x-ray detectors have recently raised attention due to their high x-ray attenuation efficiency and good charge transport properties. However, an intriguing feature of the photocurrent response of MAPbBr3 detectors has been largely overlooked in the literature. After biasing, transient sensitivity is measured under x rays at short-circuit (bias = 0 V), thus revealing a large remnant electric field that builds up under bias. Here, we exploit the x-ray sensitivity of MAPbBr3 detectors at zero-bias in order to probe the internal built-in field, as well as to investigate the charge transport properties of the perovskite material. Our model derived from the Hecht equation is able to fully rationalize the response of the detectors both at short-circuit and under moderate applied bias. Moreover, we provide a method for the estimation of the internal electric field, and for the sum of the electrons and holes mobility–lifetime products μeτe+μhτh. This general method could extend to any perovskite-based x-ray detector exhibiting transient sensitivity at zero-bias.
- 15 November 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (19)
Open AccessEvidence for a build-in remnant field in symmetrically contacted MAPbBr3 x-ray detectors
Millimeter-thick methylammonium lead tribromide (MAPbBr3) single crystal x-ray detectors have recently raised attention due to their high x-ray attenuation efficiency and good charge transport properties. However, an intriguing feature of the photocurrent response of MAPbBr3 detectors has been largely overlooked in the literature. After biasing, transient sensitivity is measured under x rays at short-circuit (bias = 0 V), thus revealing a large remnant electric field that builds up under bias. Here, we exploit the x-ray sensitivity of MAPbBr3 detectors at zero-bias in order to probe the internal built-in field, as well as to investigate the charge transport properties of the perovskite material. Our model derived from the Hecht equation is able to fully rationalize the response of the detectors both at short-circuit and under moderate applied bias. Moreover, we provide a method for the estimation of the internal electric field, and for the sum of the electrons and holes mobility–lifetime products μeτe+μhτh. This general method could extend to any perovskite-based x-ray detector exhibiting transient sensitivity at zero-bias.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19308876,p. 202-205
Printed OTFT complementary circuits and matrix for Smart Sensing Surfaces applications
Large area sensing surface have strong interest for many applicative sectors: transport, health, building, industrial, user interface. Printed electronics offers breakthrough technical solutions to fulfill these applications. Indeed printed sensors, addressed by printed oTFT matrix and circuits, heterogeneously connected to classical Silicon microprocessor for the signal processing, offers unreached solutions when multipoint, large area and flexibility are required. Recent developments in printed organic "CMOS" circuits, OTFT backplanes and sensors obtained on PICTIC large area Sheet-To-Sheet printing platform will be presented with vision on future potential applications.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19308876,p. 202-205
Printed OTFT complementary circuits and matrix for Smart Sensing Surfaces applications
Large area sensing surface have strong interest for many applicative sectors: transport, health, building, industrial, user interface. Printed electronics offers breakthrough technical solutions to fulfill these applications. Indeed printed sensors, addressed by printed oTFT matrix and circuits, heterogeneously connected to classical Silicon microprocessor for the signal processing, offers unreached solutions when multipoint, large area and flexibility are required. Recent developments in printed organic "CMOS" circuits, OTFT backplanes and sensors obtained on PICTIC large area Sheet-To-Sheet printing platform will be presented with vision on future potential applications.
- 6 April 2009
- Published by AIP Publishing in Applied Physics Letters
- Vol. 94 (14) , 143301
Effects of amorphous semiconductor thickness on top gate staggered organic field-effect transistors
We have investigated the influence of the semiconductor thickness varying by almost two orders of magnitude on the transfer and output characteristics of top gate staggered organic field-effect transistors. We observe that the mobility in the saturation regime is almost constant in the thickness range studied. In contrast, the subthreshold slope and the threshold voltage are highly impacted by the semiconductor thickness, and in particular they showed a common optimum thickness value. On both sides of this optimum we observe a loss in performances, which are tentatively attributed to different mechanisms.
- 6 April 2009
- Published by AIP Publishing in Applied Physics Letters
- Vol. 94 (14) , 143301
Effects of amorphous semiconductor thickness on top gate staggered organic field-effect transistors
We have investigated the influence of the semiconductor thickness varying by almost two orders of magnitude on the transfer and output characteristics of top gate staggered organic field-effect transistors. We observe that the mobility in the saturation regime is almost constant in the thickness range studied. In contrast, the subthreshold slope and the threshold voltage are highly impacted by the semiconductor thickness, and in particular they showed a common optimum thickness value. On both sides of this optimum we observe a loss in performances, which are tentatively attributed to different mechanisms.