Ahlem Zegueur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ahlem Zegueur has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Abderrezak Metatla
LGMM Laboratory, University of 20 Août 1955-Skikda, PB N° 26 Route Elhadaik, Skikda 21000, Algeria
2 shared publications - Toufik Sebbagh
LGMM Laboratory, Faculty of Technology, University of Skikda, Skikda 21000, Algeria
1 shared publication - Toufik Sebbagh
LGMM Laboratory, Department of Mechanical Engineering, Faculty of Technology, University of 20 August 1955, Skikda, Algeria
1 shared publication
Latest Publications
- Open Access
- 7 December 2024
- Published by Libyan Center for Solar Energy Research and Studies in Solar Energy and Sustainable Development journal
- Vol. 14 (1) , 1-19
Optimizing a Sustainable Power System with Green Hydrogen Energy Storage for Telecommunication Station Loads
Telecommunication stations situated in rural areas often rely on diesel generators as their primary energy source to meet electricity demand, given the absence of a power grid. However, this heavy dependence on diesel generators leads to escalated operational and maintenance expenses, while exacerbating global warming through greenhouse gas emissions. This paper proposes a shift towards a 100% hybrid renewable energy system integrated with hydrogen energy storage as a sustainable alternative. The proposed system incorporates photovoltaic (PV) panels, wind turbines, an electrolyzer, a fuel cell, a hydrogen tank, and a converter. Using HOMER Pro software, the optimal sizing of the system was determined, resulting in a configuration with 12.3 kW PV capacity, two 10 kW wind turbines, a 10kW fuel cell, a 20 kW electrolyzer, a 5 kg hydrogen tank, and a 17.3 kW converter. This configuration achieved a net present cost (NPC) of $155,705 and a cost of energy (COE) of $0.388/kWh, offering substantial cost-effectiveness. Compared to the base case relying solely on diesel generators, the system could avoid approximately 31,081 kg of CO₂ emissions annually. Finally, a sensitivity analysis was conducted to assess the impact of meteorological variations on the system’s economic outputs. The findings of this comprehensive study demonstrate the proposed hybrid system's feasibility in terms of both environmental sustainability and economic viability, presenting a sustainable alternative for off-grid telecommunication stations.
- 7 December 2024
- Published by Libyan Center for Solar Energy Research and Studies in Solar Energy and Sustainable Development journal
- Vol. 14 (1) , 1-19
Open AccessOptimizing a Sustainable Power System with Green Hydrogen Energy Storage for Telecommunication Station Loads
Telecommunication stations situated in rural areas often rely on diesel generators as their primary energy source to meet electricity demand, given the absence of a power grid. However, this heavy dependence on diesel generators leads to escalated operational and maintenance expenses, while exacerbating global warming through greenhouse gas emissions. This paper proposes a shift towards a 100% hybrid renewable energy system integrated with hydrogen energy storage as a sustainable alternative. The proposed system incorporates photovoltaic (PV) panels, wind turbines, an electrolyzer, a fuel cell, a hydrogen tank, and a converter. Using HOMER Pro software, the optimal sizing of the system was determined, resulting in a configuration with 12.3 kW PV capacity, two 10 kW wind turbines, a 10kW fuel cell, a 20 kW electrolyzer, a 5 kg hydrogen tank, and a 17.3 kW converter. This configuration achieved a net present cost (NPC) of $155,705 and a cost of energy (COE) of $0.388/kWh, offering substantial cost-effectiveness. Compared to the base case relying solely on diesel generators, the system could avoid approximately 31,081 kg of CO₂ emissions annually. Finally, a sensitivity analysis was conducted to assess the impact of meteorological variations on the system’s economic outputs. The findings of this comprehensive study demonstrate the proposed hybrid system's feasibility in terms of both environmental sustainability and economic viability, presenting a sustainable alternative for off-grid telecommunication stations.
- Open Access
- 26 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 56 (1) , 25
A Techno-Economic Study of a Hybrid PV–Wind–Diesel Standalone Power System for a Rural Telecommunication Station in Northeast Algeria
Telecommunication stations, particularly operating in rural areas, are usually powered by diesel generators due to the lack of access to the utility grid. However, the growing cost of energy due to the constantly increasing fuel prices and the related greenhouse gas emissions contributing to global warming have driven telecom companies to seek better energy management solutions. In this paper, we study the economic feasibility of an environmentally friendly power supply system for rural telecommunication station in the city of Skikda, northeast Algeria. The proposed system is a standalone hybrid PV–wind system with pre-existing diesel generators and battery storage. Different system configurations are considered in the study: (a) diesel generators only, (b) PV–diesel–battery, (c) wind–diesel–battery, (d) PV–wind–diesel–battery, and lastly (e) PV–wind–battery; this helps to select the optimal solution based on the lowest net present cost (NPC) and the cost of energy (COE) of each configuration. The optimization is performed using HOMER PRO software 3.14.2 version. The results showed that a hybrid system of 5 kW DG, 3.81 kW of PV capacity, three wind turbines, and a 14-battery bank is the best design for the proposed power system with an NPC of USD 85673 and a COE of USD 0.214. The greenhouse gas emissions were considerably reduced by more than half making the proposed system a technically, economically, and environmentally viable solution.
- 26 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 56 (1) , 25
Open AccessA Techno-Economic Study of a Hybrid PV–Wind–Diesel Standalone Power System for a Rural Telecommunication Station in Northeast Algeria
Telecommunication stations, particularly operating in rural areas, are usually powered by diesel generators due to the lack of access to the utility grid. However, the growing cost of energy due to the constantly increasing fuel prices and the related greenhouse gas emissions contributing to global warming have driven telecom companies to seek better energy management solutions. In this paper, we study the economic feasibility of an environmentally friendly power supply system for rural telecommunication station in the city of Skikda, northeast Algeria. The proposed system is a standalone hybrid PV–wind system with pre-existing diesel generators and battery storage. Different system configurations are considered in the study: (a) diesel generators only, (b) PV–diesel–battery, (c) wind–diesel–battery, (d) PV–wind–diesel–battery, and lastly (e) PV–wind–battery; this helps to select the optimal solution based on the lowest net present cost (NPC) and the cost of energy (COE) of each configuration. The optimization is performed using HOMER PRO software 3.14.2 version. The results showed that a hybrid system of 5 kW DG, 3.81 kW of PV capacity, three wind turbines, and a 14-battery bank is the best design for the proposed power system with an NPC of USD 85673 and a COE of USD 0.214. The greenhouse gas emissions were considerably reduced by more than half making the proposed system a technically, economically, and environmentally viable solution.