EVE. A. Vinitskiy

E. A. Vinitskiy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


E. A. Vinitskiy has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Estimate of the Absolute Measurement Error of the Electric Potential in Plasma of the T-15MD Tokamak

    by L. G. Eliseev, E. A. Vinitskiy, A. V. Melnikov, Ya. M. Ammosov, G. A. Sarancha, N. A. Vadimov

    An absolute error in measuring the plasma electric potential using the heavy ion beam probe (HIBP) is estimated for the T-15MD tokamak. The main sources of error are analyzed, including the instability of voltage and the inaccuracy of its setting in the high-voltage power supplies of the accelerator and the energy analyzer, the uncertainty in the entrance angle of the secondary ion beam into the analyzer, the noise in the measurement path and the shot noise. The error is calculated for various modes of tokamak operation with the toroidal magnetic field of BТ = 1.2–2.0 T and the chord-averaged electron density of ne = (3–5) × 1019 m–3 for different profiles of electron temperature and density. The radial plasma regions accessible to reliable potential measurement are determined. Two-dimensional distributions of the absolute error for both the average potential and its fluctuations are obtained. It is demonstrated that optimizing the analyzer plate voltage, which reduces the normalized difference in partial currents at the detector, reduces the overall measurement error by approximately a factor of four and substantially expands the sample volume.

  • MEPhIST-0 Tokamak Microwave Interferometer with Frequency Sweeping

    by E. A. Vinitskiy, A. S. Drozd, I. I. Pashkov, A. Basak, S. A. Sapronov, S. A. Krat

    The design of the MEPhIST-0 tokamak microwave interferometer and its system of data acquisition and processing are described. Examples of the time evolution of the linear electron density in MEPhIST-0 discharges are presented. The use of a phasemeter based on AD8302 detectors and digital post-processing of interferometer signals is compared. The beam refraction in the MEPhIST-0 chamber has been calculated. The possibility of plasma probing with a microwave interferometer for single- and two-pass configurations has been evaluated. It is shown that the transition to single-pass plasma probing allows the upper limit of the measured density to be significantly expanded (up to n0 = 3 × 1019 m−3).

  • Spatial Areas of Potential and Density Fluctuation Measurements Using HIBP on the T-15MD Tokamak

    by E. A. Vinitskiy, L. G. Eliseev, D. A. Shelukhin, Y. M. Ammosov, A. V. Melnikov

    The paper presents a numerical analysis of the possibility of performing local measurements of potential and plasma density fluctuations in the T-15MD tokamak using the Heavy Ion Beam Probe (HIBP) diagnostic. Four types of fluctuations are considered in the frequency range up to 500 kHz: Geodesic Acoustic Mode (GAM), Quasi-Coherent Mode (QCM), Tearing Mode (TM), and Alfvén eigenmode (AE). For each type of fluctuation, spatial measurement areas are defined for regimes with different values of average density \({{\bar {n}}_{e}}\) and toroidal magnetic field \({{B}_{T}}\). Regimes with flat and peaked density profiles are considered. It is shown that high-Q fluctuations (GAM, AE, TM) can be measured in the peripheral region of the plasma \(\rho < 0.8\) up to density \({{\bar {n}}_{e}} \leqslant 7 \times {{10}^{{19}}}\;{{{\text{m}}}^{{ - 3}}}\), while low-Q QCMs can be measured up to \({{\bar {n}}_{e}} \leqslant 5 \times {{10}^{{19}}}\;{{{\text{m}}}^{{ - 3}}}\). In the plasma gradient region \(\rho = 0.5{-} 0.9\) the measurement of high-Q fluctuations is possible at a density of \({{\bar {n}}_{e}} \leqslant 5 \times {{10}^{{19}}}\;{{{\text{m}}}^{{ - 3}}}\), and of the low-Q QCM at a density of \({{\bar {n}}_{e}} \leqslant 3 \times {{10}^{{19}}}\;{{{\text{m}}}^{{ - 3}}}\).

  • Open Access

    Determination of operating parameters of toroidal field coils of a tokamak based on a high-temperature superconductor

    by D. A. Aleksandrov, I. V. Martirosian, E. A. Vinitskiy, M. A. Osipov, S. V. Pokrovskii

    Aim: to determine the operating parameters of the toroidal magnetic field system (operating temperature, number of CORC cables, transport current value) of the MEPhIST-1 superconducting tokamak Materials and Methods: numerical calculation of the toroidal magnetic field of a tokamak was performed in the COMSOL Multiphysics software Results: magnetic field distributions were obtained for various values of the transport current flowing through the tokamak coil. The proportionality coefficients between the maximum magnetic field on the coil and the transport current, the operating magnetic field and the operating transport current were determined. Conclusion: the number of CORC cables required to achieve an operating magnetic field induction of 1 T has been determined: 7 at a temperature of 37.6 K and 6 at a temperature of 33.6 K. It has been shown that it is possible to achieve an operating field value of about 1.5T with 7 CORC cables when the temperature is lowered to 21.1 K.


  • Optimization of the Toroidal Magnetic Coil System for the Small Spherical Tokamak MEPhIST-0

    by E. A. Vinitskiy, D. L. Ulasevich, A. S. Prishvitsyn, N. E. Efimov, R. R. Khayrutdinov, S. A. Krat


  • Multiple Cell Array Detector for a Heavy Ion Beam Probe on the T-15MD Tokamak

    by E. A. Vinitskiy, O. D. Krohalev, L. G. Eliseev, A. V. Melnikov

    The potential of utilizing a multiple cell array detector (MCAD) [8] has been demonstrated as an additional tool for correlation studies of density and poloidal field fluctuations in a plasma as a part of the heavy ion beam probe on the T-15MD tokamak. The optimum position and size of the MCAD have been found, and its cell size has been determined. Trajectories of probing particles have been calculated and the plasma region for measurements has been estimated for the toroidal magnetic fields BT = 1.2, 1.5, 1.7, and 2.0 T. It has been shown that simultaneous measurements with the MCAD and the energy analyzer as the main measurement tool are possible, which allows the study of radial and poloidal spatial correlations of medium scale comparable to the small plasma radius. The spatial resolution of measurements and attenuation of the beam current signal during its passage through the plasma have been estimated.


  • Vertical stray field measurements using an electron beam in the MEPhIST-0 tokamak

    by E A Vinitskiy, N E Efimov, A S Prishvitsyn, I A Sorokin, S A Krat

    In the MEPhIST-0 tokamak, toroidal magnetic coil system is implemented as a single continuous toroidal solenoid. This design ensures synchronized operation of each segment of the solenoid and requires only one power supply line to operate. However, this configuration has the downside of introducing stray vertical and radial magnetic field components, which result from the inclination of the solenoid segments. Such stray fields can be measured using an electron beam, as previously demonstrated in experiments on T-15, TEXTOR, KSTAR, and SST-1. This paper describes the parameters of the experiment and presents the main results obtained from the MEPhIST-0 tokamak. Two experimental techniques for measuring the vertical magnetic field are discussed: one with a change in the current direction in the toroidal solenoid and one without. The ratio of the stray vertical field to the toroidal field was found to be approximately 0.5%. The conducted experiments highlight the necessity of compensating for the stray vertical field using additional poloidal coils.