Feng Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Feng Chen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Shaofeng Lu
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou 511442, China
4 shared publications - Bing Han
Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123, China
2 shared publications - Yang Peng
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, China
2 shared publications - Chaoxian Wu
School of Systems Science and Engineering, Sun Yat-sen University, Guangzhou 510275, China
1 shared publication - Fei Xue
Department of Electrical and Electronic Engineering, Xi'an Jiaotong-Liverpool University, Suzhou 215123, China
1 shared publication Fuwang Chen
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, China
1 shared publication
Latest Publications
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 73 (11) , 16148-16159
Energy-Efficient Train Control: A Comparative Study Based on Permanent Magnet Synchronous Motor and Induction Motor
The permanent magnet synchronous motor (PMSM) has recently garnered significant interest due to its high efficiency, lightweight, and low life cycle cost, positioning it as a strong candidate for the next-generation traction system in railway applications. By comparing the widely used induction motor (IM) with the PMSM, this paper integrates the dynamic motor efficiency map, which plays a crucial role in energy saving, into the energy-efficient train control (EETC) problem. The paper adopts auxiliary variables and utilizes data transformation to perform double surface-fitting for highly nonlinear and non-convex dynamic efficiency. This transformation naturally distinguishes the train traction and braking operating states, further enhancing the solution accuracy of the EETC model. Results reveal that the proposed model, while maintaining high computational accuracy, can achieve millisecond-scale computation time, and the results are closer to the actual distribution of train operating points. Based on a real case analysis of Qingdao Metro Line, it was found that replacing the IM with PMSM as a traction motor does not require adjustments to the train operation control strategy, and the PMSM can save at least 1.01 kWh/km, achieving an energy-saving rate of 12.96%.
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 73 (11) , 16148-16159
Energy-Efficient Train Control: A Comparative Study Based on Permanent Magnet Synchronous Motor and Induction Motor
The permanent magnet synchronous motor (PMSM) has recently garnered significant interest due to its high efficiency, lightweight, and low life cycle cost, positioning it as a strong candidate for the next-generation traction system in railway applications. By comparing the widely used induction motor (IM) with the PMSM, this paper integrates the dynamic motor efficiency map, which plays a crucial role in energy saving, into the energy-efficient train control (EETC) problem. The paper adopts auxiliary variables and utilizes data transformation to perform double surface-fitting for highly nonlinear and non-convex dynamic efficiency. This transformation naturally distinguishes the train traction and braking operating states, further enhancing the solution accuracy of the EETC model. Results reveal that the proposed model, while maintaining high computational accuracy, can achieve millisecond-scale computation time, and the results are closer to the actual distribution of train operating points. Based on a real case analysis of Qingdao Metro Line, it was found that replacing the IM with PMSM as a traction motor does not require adjustments to the train operation control strategy, and the PMSM can save at least 1.01 kWh/km, achieving an energy-saving rate of 12.96%.
- 16 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (3) , 7551-7564
Robust Planning of Electric Vehicle Charging Stations Considering Demand Uncertainty and Facility Failures
Carbon reduction policies and the increasing trend toward transportation electrification have spurred the rapid development of electric vehicles (EVs). However, the uncertainties of charging demands and facility failures, resulting from factors such as power disruptions, equipment damage, and inefficient operation, pose challenges in balancing the economic efficiency and service reliability of electric vehicle charging stations (EVCSs). This paper proposes a robust planning model in the coupled traffic-power network, aiming to minimize the investment costs of EVCSs and the operation costs, including detour costs for EV users, penalty costs for unmet demands, and generation costs while maintaining a controllable risk level. To solve the model, we employ the column-and-constraint generation algorithm along with the alternative directions method (C&CG-AD). Furthermore, a second-order cone programming (SOCP)-based branch flow model (BFR) is incorporated to repair the duality gap of BFR and ensure the convergence of the C&CG-AD algorithm. A comprehensive case study is conducted to validate the effectiveness of the proposed model and solution methods. The findings demonstrate that the robust solution considering both uncertainties offers superior cost-effectiveness, operational reliability, and resilience against various failures compared to strategies that either average out uncertainties or overlook facility failures.
- 16 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (3) , 7551-7564
Robust Planning of Electric Vehicle Charging Stations Considering Demand Uncertainty and Facility Failures
Carbon reduction policies and the increasing trend toward transportation electrification have spurred the rapid development of electric vehicles (EVs). However, the uncertainties of charging demands and facility failures, resulting from factors such as power disruptions, equipment damage, and inefficient operation, pose challenges in balancing the economic efficiency and service reliability of electric vehicle charging stations (EVCSs). This paper proposes a robust planning model in the coupled traffic-power network, aiming to minimize the investment costs of EVCSs and the operation costs, including detour costs for EV users, penalty costs for unmet demands, and generation costs while maintaining a controllable risk level. To solve the model, we employ the column-and-constraint generation algorithm along with the alternative directions method (C&CG-AD). Furthermore, a second-order cone programming (SOCP)-based branch flow model (BFR) is incorporated to repair the duality gap of BFR and ensure the convergence of the C&CG-AD algorithm. A comprehensive case study is conducted to validate the effectiveness of the proposed model and solution methods. The findings demonstrate that the robust solution considering both uncertainties offers superior cost-effectiveness, operational reliability, and resilience against various failures compared to strategies that either average out uncertainties or overlook facility failures.
- Open Access
- 15 November 2021
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 12 (4) , 243
Multistage and Dynamic Layout Optimization for Electric Vehicle Charging Stations Based on the Behavior Analysis of Travelers
Electric vehicles (EV) are growing fast in recent years with the widespread concern about carbon neutrality. The development of charging infrastructures needs to be in phase with EV both in terms of quantity and charging time to decrease the range anxiety of EV users and resource waste. This paper proposed a multistage and dynamic layout optimization model based on mixed integer linear programming (MILP) for EV charging stations (CSs) to minimize the total social costs (TSC) consisting of the detour cost of EV users and the construction, relocation, and operating cost of CSs. The charging satisfaction coefficient and M/M/S/K model of queuing theory has been introduced to determine the desirable charging supply. The spatial-temporal distribution of charging demand was modeled based on the behavior analysis of travelers and over the discrete-time intervals for a day. Comparison studies based on the Sioux Falls network reveal that TSC with a multistage optimization strategy will drop 8.79% from that with a one-time optimization strategy. Charging service quality, relocation cost, and road network scales have a significant impact on the optimization results according to the sensitivity analysis.
- 15 November 2021
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 12 (4) , 243
Open AccessMultistage and Dynamic Layout Optimization for Electric Vehicle Charging Stations Based on the Behavior Analysis of Travelers
Electric vehicles (EV) are growing fast in recent years with the widespread concern about carbon neutrality. The development of charging infrastructures needs to be in phase with EV both in terms of quantity and charging time to decrease the range anxiety of EV users and resource waste. This paper proposed a multistage and dynamic layout optimization model based on mixed integer linear programming (MILP) for EV charging stations (CSs) to minimize the total social costs (TSC) consisting of the detour cost of EV users and the construction, relocation, and operating cost of CSs. The charging satisfaction coefficient and M/M/S/K model of queuing theory has been introduced to determine the desirable charging supply. The spatial-temporal distribution of charging demand was modeled based on the behavior analysis of travelers and over the discrete-time intervals for a day. Comparison studies based on the Sioux Falls network reveal that TSC with a multistage optimization strategy will drop 8.79% from that with a one-time optimization strategy. Charging service quality, relocation cost, and road network scales have a significant impact on the optimization results according to the sensitivity analysis.