Gooyoon Chung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gooyoon Chung has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Yoonseok Park
Department of Materials Science and Engineering, Kyung Hee University, Yongin 17104, Republic of Korea
8 shared publications - Jeongmin Yoo
Department of Materials Science and Engineering Kyung Hee University Yongin Republic of Korea
4 shared publications - Sang Min Won
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
4 shared publications Dong-Soo Han
Center for Spintronics Korea Institute of Science and Technology Seoul 02792 Republic of Korea
2 shared publications- Gyuri Shin
Department of Materials Science and Engineering, Kyung Hee University, Yongin 17104, Republic of Korea
2 shared publications - Haiwen Luan
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
2 shared publications
Latest Publications
- Open Access
- 31 August 2026
- Published by Springer Nature in Research Square
3D µEFPocket for Multimodal Communications with Brain Organoids
Human brain organoids are powerful three-dimensional models for studying neural development, disease mechanisms, and pharmacological responses, but precise spatiotemporal chemical modulation and activity recording within intact organoids and in a simultaneous fashion is difficult due to their three-dimensional (3D) complexities. Here, we introduce the microElectroFluidicPocket (µEFPocket), a conformal, ultrathin microfluidic 3D biointerface that integrates microscale spatiotemporal control of chemical and electrical stimulation in human cortical organoids with simultaneous optical and electrical readout. Fabricated entirely from parylene C using standard wafer-scale deposition, photolithography, and etching, µEFPockets form integrated, mechanically compliant architectures that wrap around spherical organoids without attachment factors, enabling repeated use of the same organoid. Engineered and independently addressable microchannels enable localized, time-locked delivery of neurotransmitters with hundreds-micron spatial resolution and second-level temporal control while preserving global culture conditions. Using glutamate delivery or electrical stimulation of GCaMP-expressing human cortical organoids, we demonstrate spatially localized calcium responses at regional and single-neuron resolution, revealing network propagation and stimulus-dependent adaptation. This scalable platform provides a foundation for spatially patterned pharmacology, multimodal biointerfaces, and closed-loop functional assays in organoids.
- 31 August 2026
- Published by Springer Nature in Research Square
Open Access3D µEFPocket for Multimodal Communications with Brain Organoids
Human brain organoids are powerful three-dimensional models for studying neural development, disease mechanisms, and pharmacological responses, but precise spatiotemporal chemical modulation and activity recording within intact organoids and in a simultaneous fashion is difficult due to their three-dimensional (3D) complexities. Here, we introduce the microElectroFluidicPocket (µEFPocket), a conformal, ultrathin microfluidic 3D biointerface that integrates microscale spatiotemporal control of chemical and electrical stimulation in human cortical organoids with simultaneous optical and electrical readout. Fabricated entirely from parylene C using standard wafer-scale deposition, photolithography, and etching, µEFPockets form integrated, mechanically compliant architectures that wrap around spherical organoids without attachment factors, enabling repeated use of the same organoid. Engineered and independently addressable microchannels enable localized, time-locked delivery of neurotransmitters with hundreds-micron spatial resolution and second-level temporal control while preserving global culture conditions. Using glutamate delivery or electrical stimulation of GCaMP-expressing human cortical organoids, we demonstrate spatially localized calcium responses at regional and single-neuron resolution, revealing network propagation and stimulus-dependent adaptation. This scalable platform provides a foundation for spatially patterned pharmacology, multimodal biointerfaces, and closed-loop functional assays in organoids.
- Open Access
- 26 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (26) , eaeg0480
Magnetically levitated metasurface enabling tangible and bidirectional human-machine interaction
Mechanical metasurfaces are deformable surfaces that reconfigure their shape in response to external stimuli, with growing applications in interactive displays and human-machine interfaces. However, many existing systems are either too fragile for physical interaction or too slow to match human response. Moreover, their incompatibility for integrating functional systems constrains seamless interaction with humans. We developed a robust, rapidly responsive, and multifunctional soft metasurface capable of intuitive interaction with humans. The soft surface reconfigures through magnetic actuation, enabling mechanical metasurface functions with simultaneous visual and tactile feedback for human interaction. The system features a six-by-six array of elastomeric pixels, each actuated by attractive or repulsive magnetic forces from an underlying electromagnet array. The induced magnetic force modulates the surface height up to 8.5 millimeters (−5 to 3.5 millimeters), enabling coordinated actuation of 36 electromagnets to reconstruct over 10 30 discrete surface morphologies. Its mechanics compliant design allows human interaction such as pushing, pulling, and pinching. Embedded inertial measurement unit sensors reconstruct surface shape in real time, and an integrated light-emitting diode array provides immediate visual feedback. This platform enables fast, reversible, and intuitive interaction between users and programmable surfaces, laying the groundwork for next-generation human-machine interaction systems.
- 26 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (26) , eaeg0480
Open AccessMagnetically levitated metasurface enabling tangible and bidirectional human-machine interaction
Mechanical metasurfaces are deformable surfaces that reconfigure their shape in response to external stimuli, with growing applications in interactive displays and human-machine interfaces. However, many existing systems are either too fragile for physical interaction or too slow to match human response. Moreover, their incompatibility for integrating functional systems constrains seamless interaction with humans. We developed a robust, rapidly responsive, and multifunctional soft metasurface capable of intuitive interaction with humans. The soft surface reconfigures through magnetic actuation, enabling mechanical metasurface functions with simultaneous visual and tactile feedback for human interaction. The system features a six-by-six array of elastomeric pixels, each actuated by attractive or repulsive magnetic forces from an underlying electromagnet array. The induced magnetic force modulates the surface height up to 8.5 millimeters (−5 to 3.5 millimeters), enabling coordinated actuation of 36 electromagnets to reconstruct over 10 30 discrete surface morphologies. Its mechanics compliant design allows human interaction such as pushing, pulling, and pinching. Embedded inertial measurement unit sensors reconstruct surface shape in real time, and an integrated light-emitting diode array provides immediate visual feedback. This platform enables fast, reversible, and intuitive interaction between users and programmable surfaces, laying the groundwork for next-generation human-machine interaction systems.
- Open Access
- 25 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (17) , eadu5919
Magnetically driven triboelectric nanogenerator for a wireless, versatile energy transfer system
The development of stable and multifunctional monitoring or actuating systems for implantable biomedical devices necessitates a high-capacity power supply. By using the oscillation of a magnetic field, energy can be transmitted through various media such as skin, fat, liquids, metals, and fabrics. We demonstrate a magnetically actuated implantable triboelectric generator that can effectively transfer energy independently of the surrounding media. The oscillation of the magnetic field enables contact of elastomeric magnets with the top and bottom electrodes of the generator, generating a path for electrical energy through contact electrification. The performance of the magnetically actuated triboelectric generator exhibits high tolerability for lateral and angular misalignment, transferring energy through different media including tissue, liquid, air, wood, metal, and fabrics. This addresses a critical issue present in ultrasound approaches. These findings suggest that a magnetically actuated triboelectric generator can be an alternative technology capable of overcoming the medium-related challenges of ultrasound, providing power to medical implants.
- 25 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (17) , eadu5919
Open AccessMagnetically driven triboelectric nanogenerator for a wireless, versatile energy transfer system
The development of stable and multifunctional monitoring or actuating systems for implantable biomedical devices necessitates a high-capacity power supply. By using the oscillation of a magnetic field, energy can be transmitted through various media such as skin, fat, liquids, metals, and fabrics. We demonstrate a magnetically actuated implantable triboelectric generator that can effectively transfer energy independently of the surrounding media. The oscillation of the magnetic field enables contact of elastomeric magnets with the top and bottom electrodes of the generator, generating a path for electrical energy through contact electrification. The performance of the magnetically actuated triboelectric generator exhibits high tolerability for lateral and angular misalignment, transferring energy through different media including tissue, liquid, air, wood, metal, and fabrics. This addresses a critical issue present in ultrasound approaches. These findings suggest that a magnetically actuated triboelectric generator can be an alternative technology capable of overcoming the medium-related challenges of ultrasound, providing power to medical implants.
- Open Access
- 16 February 2025
- Published by Wiley in Advanced Materials
- Vol. 37 (16) , e2419504
Bio‐Inspired, Miniaturized Magnetic Heart Valve System for Superior Performance Cardiovascular Simulator
The demand for accurate vascular simulators is increasing to facilitate effective clinical studies on cardiovascular diseases. The research presents the miniaturized design and precise programable regulation of an artificial magnetic heart valve inspired by the human aortic valve, demonstrating the diverse types of pulsating waves. The heart valve is constructed using an elastomeric silicone composite embedded with neodymium magnetic micro‐particles. This valve system responds rapidly to changes in magnetic fields controlled by miniaturized electromagnets, enabling precise regulation of fluid pressure and flow rate. This allows for the generation of various pressure waveforms and accurately replicates diverse blood pressure changes with a compact design. The design, working mechanism, fabrication process, and optimization of the magnetically controlled biomimetic heart valve are discussed and its performance as a cardiovascular simulator for human and animal models is evaluated. This artificial valve system has the potential to be utilized in humanoid robots to generate heart‐like pressure, thereby paving the way for replicating human physiological characteristics. This research promises significant advancements in cardiovascular clinical trials and biomedical research along with the development of humanoid robots and biomimetic mechanical systems.
- 16 February 2025
- Published by Wiley in Advanced Materials
- Vol. 37 (16) , e2419504
Open AccessBio‐Inspired, Miniaturized Magnetic Heart Valve System for Superior Performance Cardiovascular Simulator
The demand for accurate vascular simulators is increasing to facilitate effective clinical studies on cardiovascular diseases. The research presents the miniaturized design and precise programable regulation of an artificial magnetic heart valve inspired by the human aortic valve, demonstrating the diverse types of pulsating waves. The heart valve is constructed using an elastomeric silicone composite embedded with neodymium magnetic micro‐particles. This valve system responds rapidly to changes in magnetic fields controlled by miniaturized electromagnets, enabling precise regulation of fluid pressure and flow rate. This allows for the generation of various pressure waveforms and accurately replicates diverse blood pressure changes with a compact design. The design, working mechanism, fabrication process, and optimization of the magnetically controlled biomimetic heart valve are discussed and its performance as a cardiovascular simulator for human and animal models is evaluated. This artificial valve system has the potential to be utilized in humanoid robots to generate heart‐like pressure, thereby paving the way for replicating human physiological characteristics. This research promises significant advancements in cardiovascular clinical trials and biomedical research along with the development of humanoid robots and biomimetic mechanical systems.
- Open Access
- 15 October 2024
- Published by Wiley in Advanced Intelligent Systems
- Vol. 6 (10)
Reprogrammable, Recyclable Origami Robots Controlled by Magnetic Fields
- 15 October 2024
- Published by Wiley in Advanced Intelligent Systems
- Vol. 6 (10)
Open AccessReprogrammable, Recyclable Origami Robots Controlled by Magnetic Fields
- Open Access
- 13 September 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (37) , eado7089
Simultaneous electromechanical monitoring in engineered heart tissues using a mesoscale framework
Engineered heart tissues (EHTs) generated from human induced pluripotent stem cell–derived cardiomyocytes (hiPSC-CMs) represent powerful platforms for human cardiac research, especially in drug testing and disease modeling. Here, we report a flexible, three-dimensional electronic framework that enables real-time, spatiotemporal analysis of electrophysiologic and mechanical signals in EHTs under physiological loading conditions for dynamic, noninvasive, longer-term assessments. These electromechanically monitored EHTs support multisite measurements throughout the tissue under baseline conditions and in response to stimuli. Demonstrations include uses in tracking physiological responses to pharmacologically active agents and in capturing electrophysiological characteristics of reentrant arrhythmias. This platform facilitates precise analysis of signal location and conduction velocity in human cardiomyocyte tissues, as the basis for a broad range of advanced cardiovascular studies.
- 13 September 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (37) , eado7089
Open AccessSimultaneous electromechanical monitoring in engineered heart tissues using a mesoscale framework
Engineered heart tissues (EHTs) generated from human induced pluripotent stem cell–derived cardiomyocytes (hiPSC-CMs) represent powerful platforms for human cardiac research, especially in drug testing and disease modeling. Here, we report a flexible, three-dimensional electronic framework that enables real-time, spatiotemporal analysis of electrophysiologic and mechanical signals in EHTs under physiological loading conditions for dynamic, noninvasive, longer-term assessments. These electromechanically monitored EHTs support multisite measurements throughout the tissue under baseline conditions and in response to stimuli. Demonstrations include uses in tracking physiological responses to pharmacologically active agents and in capturing electrophysiological characteristics of reentrant arrhythmias. This platform facilitates precise analysis of signal location and conduction velocity in human cardiomyocyte tissues, as the basis for a broad range of advanced cardiovascular studies.
- Open Access
- 2 June 2024
- Published by Wiley in Advanced Intelligent Systems
- Vol. 6 (10)
Reprogrammable, Recyclable Origami Robots Controlled by Magnetic Fields
Origami, the art of paper folding, has emerged as a versatile technique for crafting intricate 3D structures from 2D sheets. Combined with the magnetic actuation, origami paper becomes the building blocks for cost‐effective, wirelessly controllable magnetic robots. Herein, a biodegradable magnetic paper with excellent formability and recyclability is developed, facilitating its convenient utilization and disposal. The programable magnetic paper, fabricated with specific magnetization and crease patterns, enables the transformation of 2D sheets into predetermined 3D structures. Leveraging the lightweight and pliable nature of paper‐based materials, exceptional control of origami robots with fast response is demonstrated, enabling a wide range of locomotion. Furthermore, the paper‐based approach enables the incorporation of electronic functionality into magnetic actuators. By introducing conductive nanoparticles into magnetic paper, an electrically conductive substance is created. Constructing electronic circuits and integrating electronic components onto the paper‐based printed circuit board platform enables the repairing of broken circuits inside complicated equipment and optical sensing of surrounding environments in conjunction with locomotive robots. The origami robots have a huge potential to be facilitated in diverse fields with various functions, demonstrating complex locomotion, and integrating chemical, optical, thermal, and mechanical sensors for monitoring environmental conditions in hard‐to‐reach locations. The array of possibilities holds significant promise for the widespread application of these origami magnetic robots across a diverse spectrum of research fields in soft robotics.
- 2 June 2024
- Published by Wiley in Advanced Intelligent Systems
- Vol. 6 (10)
Open AccessReprogrammable, Recyclable Origami Robots Controlled by Magnetic Fields
Origami, the art of paper folding, has emerged as a versatile technique for crafting intricate 3D structures from 2D sheets. Combined with the magnetic actuation, origami paper becomes the building blocks for cost‐effective, wirelessly controllable magnetic robots. Herein, a biodegradable magnetic paper with excellent formability and recyclability is developed, facilitating its convenient utilization and disposal. The programable magnetic paper, fabricated with specific magnetization and crease patterns, enables the transformation of 2D sheets into predetermined 3D structures. Leveraging the lightweight and pliable nature of paper‐based materials, exceptional control of origami robots with fast response is demonstrated, enabling a wide range of locomotion. Furthermore, the paper‐based approach enables the incorporation of electronic functionality into magnetic actuators. By introducing conductive nanoparticles into magnetic paper, an electrically conductive substance is created. Constructing electronic circuits and integrating electronic components onto the paper‐based printed circuit board platform enables the repairing of broken circuits inside complicated equipment and optical sensing of surrounding environments in conjunction with locomotive robots. The origami robots have a huge potential to be facilitated in diverse fields with various functions, demonstrating complex locomotion, and integrating chemical, optical, thermal, and mechanical sensors for monitoring environmental conditions in hard‐to‐reach locations. The array of possibilities holds significant promise for the widespread application of these origami magnetic robots across a diverse spectrum of research fields in soft robotics.
- Open Access
- 29 January 2024
- Published by Springer Nature in npj Flexible Electronics
- Vol. 8 (1) , 1-8
Soft, full Wheatstone bridge 3D pressure sensors for cardiovascular monitoring
Variations in parameters associated with the ambient environment can introduce noise in soft, body-worn sensors. For example, many piezoresistive pressure sensors exhibit a high degree of sensitivity to fluctuations in temperature, thereby requiring active compensation strategies. The research presented here addresses this challenge with a multilayered 3D microsystem design that integrates four piezoresistive sensors in a full-Wheatstone bridge configuration. An optimized layout of the sensors relative to the neutral mechanical plane leads to both an insensitivity to temperature and an increased sensitivity to pressure, relative to previously reported devices that rely on similar operating principles. Integrating this 3D pressure sensor into a soft, flexible electronics platform yields a system capable of real-time, wireless measurements from the surface of the skin. Placement above the radial and carotid arteries yields high-quality waveforms associated with pulsatile blood flow, with quantitative correlations to blood pressure. The results establish the materials and engineering aspects of a technology with broad potential in remote health monitoring.
- 29 January 2024
- Published by Springer Nature in npj Flexible Electronics
- Vol. 8 (1) , 1-8
Open AccessSoft, full Wheatstone bridge 3D pressure sensors for cardiovascular monitoring
Variations in parameters associated with the ambient environment can introduce noise in soft, body-worn sensors. For example, many piezoresistive pressure sensors exhibit a high degree of sensitivity to fluctuations in temperature, thereby requiring active compensation strategies. The research presented here addresses this challenge with a multilayered 3D microsystem design that integrates four piezoresistive sensors in a full-Wheatstone bridge configuration. An optimized layout of the sensors relative to the neutral mechanical plane leads to both an insensitivity to temperature and an increased sensitivity to pressure, relative to previously reported devices that rely on similar operating principles. Integrating this 3D pressure sensor into a soft, flexible electronics platform yields a system capable of real-time, wireless measurements from the surface of the skin. Placement above the radial and carotid arteries yields high-quality waveforms associated with pulsatile blood flow, with quantitative correlations to blood pressure. The results establish the materials and engineering aspects of a technology with broad potential in remote health monitoring.
- Top Cited Papers
- 16 November 2023
- Published by Springer Nature in Nature Medicine
- Vol. 29 (12) , 3137-3148
Wireless broadband acousto-mechanical sensing system for continuous physiological monitoring
The human body generates various forms of subtle, broadband acousto-mechanical signals that contain information on cardiorespiratory and gastrointestinal health with potential application for continuous physiological monitoring. Existing device options, ranging from digital stethoscopes to inertial measurement units, offer useful capabilities but have disadvantages such as restricted measurement locations that prevent continuous, longitudinal tracking and that constrain their use to controlled environments. Here we present a wireless, broadband acousto-mechanical sensing network that circumvents these limitations and provides information on processes including slow movements within the body, digestive activity, respiratory sounds and cardiac cycles, all with clinical grade accuracy and independent of artifacts from ambient sounds. This system can also perform spatiotemporal mapping of the dynamics of gastrointestinal processes and airflow into and out of the lungs. To demonstrate the capabilities of this system we used it to monitor constrained respiratory airflow and intestinal motility in neonates in the neonatal intensive care unit (n = 15), and to assess regional lung function in patients undergoing thoracic surgery (n = 55). This broadband acousto-mechanical sensing system holds the potential to help mitigate cardiorespiratory instability and manage disease progression in patients through continuous monitoring of physiological signals, in both the clinical and nonclinical setting.
- 16 November 2023
- Published by Springer Nature in Nature Medicine
- Vol. 29 (12) , 3137-3148
Top Cited PapersWireless broadband acousto-mechanical sensing system for continuous physiological monitoring
The human body generates various forms of subtle, broadband acousto-mechanical signals that contain information on cardiorespiratory and gastrointestinal health with potential application for continuous physiological monitoring. Existing device options, ranging from digital stethoscopes to inertial measurement units, offer useful capabilities but have disadvantages such as restricted measurement locations that prevent continuous, longitudinal tracking and that constrain their use to controlled environments. Here we present a wireless, broadband acousto-mechanical sensing network that circumvents these limitations and provides information on processes including slow movements within the body, digestive activity, respiratory sounds and cardiac cycles, all with clinical grade accuracy and independent of artifacts from ambient sounds. This system can also perform spatiotemporal mapping of the dynamics of gastrointestinal processes and airflow into and out of the lungs. To demonstrate the capabilities of this system we used it to monitor constrained respiratory airflow and intestinal motility in neonates in the neonatal intensive care unit (n = 15), and to assess regional lung function in patients undergoing thoracic surgery (n = 55). This broadband acousto-mechanical sensing system holds the potential to help mitigate cardiorespiratory instability and manage disease progression in patients through continuous monitoring of physiological signals, in both the clinical and nonclinical setting.