KAK. K. Anjum

K. K. Anjum

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


K. K. Anjum has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Road transport of trapped antiprotons

    by M. Leonhardt, J. Morgner, F. Abbass, K. K. Anjum, B. Arndt, R. P. Czampiel, N. Daehnhardt, S. Endoh, T. Imamura, J. I. Jäger, et al.

    Low-energy antiprotons confined in ultrahigh-vacuum Penning traps 1 enable precision investigations of charge, parity and time-reversal (CPT) invariance 2 to test the fundamental symmetry between matter and antimatter. These studies are driven by the search for physics beyond the standard model of particle physics, including efforts to explain the observed cosmological matter–antimatter asymmetry. Until now, such experiments have only been possible at CERN’s Antimatter Factory 3,4 . At present, magnetic-field fluctuations caused by the facility operation limit the sensitivity of trapped-antiproton precision measurements 5 , which provide the most stringent matter–antimatter symmetry tests in the baryon sector 6–9 . This has inspired us to develop the cryogenic, open and transportable Penning-trap system BASE-STEP 5,10 , designed to relocate antiprotons into low-noise offline laboratories, a strategy expected to enable at least 100-fold improved CPT tests 9,11 . Here we demonstrate the road transport of antiprotons trapped in BASE-STEP. Ninety-two trapped antiprotons have been transported outside the Antimatter Factory along a 7.5-km route without particle loss or measurable degradation of the trap vacuum. This achievement marks the starting point for a new era of antiproton precision measurements 8,12 in dedicated low-noise offline laboratory environments.


  • Open Access

    Proton transport from the antimatter factory of CERN

    by M. Leonhardt, D. Schweitzer, F. Abbass, K. K. Anjum, B. Arndt, S. Erlewein, S. Endoh, P. Geissler, T. Imamura, J. I. Jäger, et al.

    Precision measurements using low-energy antiprotons, exclusively available at the antimatter factory (AMF) of CERN 1 , offer stringent tests of charge–parity–time (CPT) invariance, which is a fundamental symmetry in the Standard Model of particle physics 2 . These tests have been realized, for example, in antiprotonic helium 3 and antihydrogen 4 . In our cryogenic Penning-trap experiments 5 , we measure the magnetic moments 6,7 and charge-to-mass ratios of protons and antiprotons and now provide the most precise test of CPT invariance in the baryon sector 8 . Our experiments are limited by magnetic field fluctuations imposed by the decelerators in the AMF; therefore, we are advancing the relocation of antiprotons to dedicated precision laboratories. Here we present the successful transport of a trapped proton cloud from the AMF using BASE-STEP 9 —a transportable, superconducting, autonomous and open Penning-trap system that can distribute antiprotons into other experiments. We transferred the trapped protons from our experimental area at the AMF onto a truck and transported them across the Meyrin site of CERN, demonstrating autonomous operation without external power for 4 h and loss-free proton relocation. We thereby confirm the feasibility of transferring particles into low-noise laboratories in the vicinity of the AMF and of using a power generator on the truck 10 to reach laboratories throughout Europe. This marks the potential start of a new era in precision antimatter research, enabling low-noise measurements of antiprotons, the charged antimatter ions $${\bar{{\rm{H}}}}^{+}$$ H ¯ + 11 and $${\bar{{\rm{H}}}}_{2}^{-}$$ H ¯ 2 − (ref. 12 ), and other accelerator-produced ions, such as hydrogen-like lead or uranium ions 13,14 .


  • Open Access

    Cryogenic vacuum valve with actuation times down to 50 ms

    by J. W. Klimes, Kanika, A. Krishnan, B. Reich, K. K. Anjum, P. Baus, G. Birkl, W. Quint, W. Schott, M. Vogel

    We have conceived, built, and operated a cryogenic vacuum valve with opening and closing times as short as 50 ms that can be used in strong magnetic fields and across a broad range of duty cycles. It is used to seal a cryogenic Penning trap at liquid-helium temperature for long-term storage of highly charged ions in a vacuum better than 10−15 hPa from a room-temperature ion beamline at vacuum conditions around 10−9 hPa. It will significantly improve any experiment where a volume at the most extreme vacuum conditions must be temporarily connected to a less demanding vacuum during repeated experimental cycles. We describe the design of this valve and show measurements that characterize its main features.