Takashi Morise
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takashi Morise has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Akira Madarame
Affiliation Department of Gastroenterology and Hepatology, Tokyo Medical University Hospital, Tokyo, Japan
3 shared publications - Masakatsu Fukuzawa
Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo 160-0023, Japan
3 shared publications - Takao Itoi
Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo 160-0023, Japan
3 shared publications - Hayato Yamaguchi
Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
2 shared publications - Kumiko Uchida
Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
2 shared publications - Sakiko Naito
Department of Gastroenterology and Hepatology, Tokyo Medical University Hospital, Tokyo, Japan
2 shared publications
Latest Publications
- Open Access
- 22 October 2026
- Published by MDPI AG in Medical Sciences
- Vol. 14 (7) , 695
Salivary Polyamine Ratios as Candidate Biomarkers for Gastric Cancer: A Proof-of-Concept Case–Control Study
Background/Objectives: Gastric cancer (GC) is one of the most prevalent malignancies worldwide, highlighting the need for minimally invasive and highly accurate screening methods for its early detection. We evaluated the utility of salivary polyamine-based metabolomic analysis for distinguishing individuals with GC from those without GC. Methods: A total of 53 patients with GC and 37 non-GC controls were included. Participants were recruited from individuals who underwent upper gastrointestinal endoscopy at Tokyo Medical University Hospital between March 2020 and May 2025 and provided saliva samples on the same day. Participants with factors known to affect polyamine levels were excluded. Salivary metabolites quantified by liquid chromatography–mass spectrometry were statistically compared between groups. Acetylated-to-non-acetylated polyamine ratios were used as features to construct a logistic regression-based machine learning model, and discriminative performance was evaluated using receiver operating characteristic analysis. Results: The GC group showed significantly higher concentrations of salivary metabolites. Among individual polyamines, N1-acetylspermine demonstrated the highest discriminative ability (AUC = 0.845). When acetylated-to-non-acetylated polyamine ratios were analyzed, significant differences between groups were observed for N1,N8-diacetylspermidine/spermidine and N1-acetylspermine/spermine. A logistic regression model constructed using six such ratios achieved strong predictive performance in the test dataset (AUC = 0.807), with a sensitivity of 68.8% and a specificity of 72.7%. Conclusions: Our results demonstrate that salivary polyamine analysis, particularly using acetylation ratios, enables accurate and minimally invasive discriminative ability of GC and represents a promising adjunctive tool for GC screening.
- 22 October 2026
- Published by MDPI AG in Medical Sciences
- Vol. 14 (7) , 695
Open AccessSalivary Polyamine Ratios as Candidate Biomarkers for Gastric Cancer: A Proof-of-Concept Case–Control Study
Background/Objectives: Gastric cancer (GC) is one of the most prevalent malignancies worldwide, highlighting the need for minimally invasive and highly accurate screening methods for its early detection. We evaluated the utility of salivary polyamine-based metabolomic analysis for distinguishing individuals with GC from those without GC. Methods: A total of 53 patients with GC and 37 non-GC controls were included. Participants were recruited from individuals who underwent upper gastrointestinal endoscopy at Tokyo Medical University Hospital between March 2020 and May 2025 and provided saliva samples on the same day. Participants with factors known to affect polyamine levels were excluded. Salivary metabolites quantified by liquid chromatography–mass spectrometry were statistically compared between groups. Acetylated-to-non-acetylated polyamine ratios were used as features to construct a logistic regression-based machine learning model, and discriminative performance was evaluated using receiver operating characteristic analysis. Results: The GC group showed significantly higher concentrations of salivary metabolites. Among individual polyamines, N1-acetylspermine demonstrated the highest discriminative ability (AUC = 0.845). When acetylated-to-non-acetylated polyamine ratios were analyzed, significant differences between groups were observed for N1,N8-diacetylspermidine/spermidine and N1-acetylspermine/spermine. A logistic regression model constructed using six such ratios achieved strong predictive performance in the test dataset (AUC = 0.807), with a sensitivity of 68.8% and a specificity of 72.7%. Conclusions: Our results demonstrate that salivary polyamine analysis, particularly using acetylation ratios, enables accurate and minimally invasive discriminative ability of GC and represents a promising adjunctive tool for GC screening.
- Open Access
- 27 August 2026
- Published by JMIR Publications Inc. in JMIR XR and Spatial Computing
- Vol. 3, e99446
A Conceptual Framework for 4D Holographic Visualization in Gastrointestinal Endoscopy: Toward Externalized Spatiotemporal Cognition
This viewpoint explores the concept of 4D holographic visualization in gastrointestinal endoscopy and discusses its potential implications from a medical informatics perspective. Current endoscopic practice relies primarily on 2D image displays, requiring operators to mentally reconstruct 3D spatial relationships and temporal changes in a dynamic and deformable anatomical environment. The aim of this viewpoint is to present a conceptual framework that reframes endoscopic visualization as a spatiotemporal information integration problem rather than solely a display problem. We discuss how future visualization systems may integrate spatial and temporal information to support externalized representations of anatomy, endoscope configuration, and procedural dynamics in a shared clinical environment. Potential applications include endoscopic navigation, training, and collaborative procedures. We further discuss key technical and clinical considerations, including information integration, registration stability, real-time responsiveness, workflow compatibility, and uncertainty associated with reconstructed information. This viewpoint highlights spatiotemporal information integration as a central challenge in the development of next-generation visualization systems for gastrointestinal endoscopy.
- 27 August 2026
- Published by JMIR Publications Inc. in JMIR XR and Spatial Computing
- Vol. 3, e99446
Open AccessA Conceptual Framework for 4D Holographic Visualization in Gastrointestinal Endoscopy: Toward Externalized Spatiotemporal Cognition
This viewpoint explores the concept of 4D holographic visualization in gastrointestinal endoscopy and discusses its potential implications from a medical informatics perspective. Current endoscopic practice relies primarily on 2D image displays, requiring operators to mentally reconstruct 3D spatial relationships and temporal changes in a dynamic and deformable anatomical environment. The aim of this viewpoint is to present a conceptual framework that reframes endoscopic visualization as a spatiotemporal information integration problem rather than solely a display problem. We discuss how future visualization systems may integrate spatial and temporal information to support externalized representations of anatomy, endoscope configuration, and procedural dynamics in a shared clinical environment. Potential applications include endoscopic navigation, training, and collaborative procedures. We further discuss key technical and clinical considerations, including information integration, registration stability, real-time responsiveness, workflow compatibility, and uncertainty associated with reconstructed information. This viewpoint highlights spatiotemporal information integration as a central challenge in the development of next-generation visualization systems for gastrointestinal endoscopy.
- Open Access
- 30 November 2023
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 56 (6) , 778-789
Significance of rescue hybrid endoscopic submucosal dissection in difficult colorectal cases
Background/Aims: Hybrid endoscopic submucosal dissection (ESD), in which an incision is made around a lesion and snaring is performed after submucosal dissection, has some advantages in colorectal surgery, including shorter procedure time and preventing perforation. However, its value for rescue resection in difficult colorectal ESD cases remains unclear. This study evaluated the utility of rescue hybrid ESD (RH-ESD).Methods: We divided 364 colorectal ESD procedures into the conventional ESD group (C-ESD, n=260), scheduled hybrid ESD group (SH-ESD, n=69), and RH-ESD group (n=35) and compared their clinical outcomes.Results: Resection time was significantly shorter in the following order: RH-ESD (149 [90–197] minutes) >C-ESD (90 [60–140] minutes) >SH-ESD (52 [29–80] minutes). The en bloc resection rate increased significantly in the following order: RH-ESD (48.6%), SH-ESD (78.3%), and C-ESD (97.7%). An analysis of factors related to piecemeal resection of RH-ESD revealed that the submucosal dissection rate was significantly lower in the piecemeal resection group (25% [20%–30%]) than in the en bloc resection group (40% [20%–60%]).Conclusions: RH-ESD was ineffective in terms of curative resection because of the low en bloc resection rate, but was useful for avoiding surgery.
- 30 November 2023
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 56 (6) , 778-789
Open AccessSignificance of rescue hybrid endoscopic submucosal dissection in difficult colorectal cases
Background/Aims: Hybrid endoscopic submucosal dissection (ESD), in which an incision is made around a lesion and snaring is performed after submucosal dissection, has some advantages in colorectal surgery, including shorter procedure time and preventing perforation. However, its value for rescue resection in difficult colorectal ESD cases remains unclear. This study evaluated the utility of rescue hybrid ESD (RH-ESD).Methods: We divided 364 colorectal ESD procedures into the conventional ESD group (C-ESD, n=260), scheduled hybrid ESD group (SH-ESD, n=69), and RH-ESD group (n=35) and compared their clinical outcomes.Results: Resection time was significantly shorter in the following order: RH-ESD (149 [90–197] minutes) >C-ESD (90 [60–140] minutes) >SH-ESD (52 [29–80] minutes). The en bloc resection rate increased significantly in the following order: RH-ESD (48.6%), SH-ESD (78.3%), and C-ESD (97.7%). An analysis of factors related to piecemeal resection of RH-ESD revealed that the submucosal dissection rate was significantly lower in the piecemeal resection group (25% [20%–30%]) than in the en bloc resection group (40% [20%–60%]).Conclusions: RH-ESD was ineffective in terms of curative resection because of the low en bloc resection rate, but was useful for avoiding surgery.