Jiale Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiale Yang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Jihao Shi
Department of Building Environment and Energy Engineering The Hong Kong Polytechnic University Kowloon Hong Kong China
2 shared publications - Xianfeng Chen
School of Safety Science and Emergency Management, Wuhan University of Technology, Wuhan 430070, China
2 shared publications - Xuxu Sun
School of Safety Science and Emergency Management, Wuhan University of Technology, Wuhan 430070, China
2 shared publications Jihao Shi
1 shared publicationJun Wang
1 shared publication- Jun Wang
School of Safety Science and Emergency Management, Wuhan University of Technology, Wuhan 430070, China
1 shared publication
Latest Publications
- 17 November 2023
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 181, 205-218
Experimental investigation of hydrogen jet flame inhibition by nitrogen jet
- 17 November 2023
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 181, 205-218
Experimental investigation of hydrogen jet flame inhibition by nitrogen jet
- Open Access
Analytical Model of Critical Ventilation Flow Rate for Accidental Hydrogen Leakage in a Confined Space
The determination of the critical ventilation flow rate is significant for risk control and standard development during accidental hydrogen leakage in a confined space with hydrogen-related equipment. This paper presents an analytical model for calculating the critical ventilation flow rate through the quantification and constraint solution of the ventilation effect and ventilation cost. The experimental method was used to investigate the effects of nozzle diameter and stagnation pressure on the diffusion and ventilation of horizontal hydrogen leakage in a cuboid chamber. Ventilations from 30 to 180 m3/h were carried out through the rectangular vent. It was shown that the peak concentration of the measuring point was positively correlated with the stagnation pressure and the nozzle diameter. The experimental data were used to verify the analytical model by calculating the effective ventilation time. This study demonstrates that the critical ventilation flow rate can be increased significantly at higher stagnation pressures and larger nozzle diameters. Furthermore, the discrepancy of critical ventilation flow rates under different nozzle diameters will be enhanced with the increase of stagnation pressure. For a stagnation pressure of 0.4 MPa, the critical ventilation flow rate under a 4 mm nozzle even increased by 52% relative to the 2 mm nozzle.
Open AccessAnalytical Model of Critical Ventilation Flow Rate for Accidental Hydrogen Leakage in a Confined Space
The determination of the critical ventilation flow rate is significant for risk control and standard development during accidental hydrogen leakage in a confined space with hydrogen-related equipment. This paper presents an analytical model for calculating the critical ventilation flow rate through the quantification and constraint solution of the ventilation effect and ventilation cost. The experimental method was used to investigate the effects of nozzle diameter and stagnation pressure on the diffusion and ventilation of horizontal hydrogen leakage in a cuboid chamber. Ventilations from 30 to 180 m3/h were carried out through the rectangular vent. It was shown that the peak concentration of the measuring point was positively correlated with the stagnation pressure and the nozzle diameter. The experimental data were used to verify the analytical model by calculating the effective ventilation time. This study demonstrates that the critical ventilation flow rate can be increased significantly at higher stagnation pressures and larger nozzle diameters. Furthermore, the discrepancy of critical ventilation flow rates under different nozzle diameters will be enhanced with the increase of stagnation pressure. For a stagnation pressure of 0.4 MPa, the critical ventilation flow rate under a 4 mm nozzle even increased by 52% relative to the 2 mm nozzle.
- Open Access
- 6 September 2023
- Published by MDPI AG in Preprints.org
Analytical Model of Critical Ventilation Flow Rate for Accidental Hydrogen Leakage in a Confined Space
The determination of critical ventilation flow rate is significant for the risk control and the standard development during accidental hydrogen leakage in a confined space with hydrogen-related equipment. In this paper, an analytical model for calculating critical ventilation flow rate was proposed through the quantification and constraint solution of ventilation effect and ventilation cost. The experimental method was used to investigate the effects of nozzle diameter and stagnation pressure on diffusion and ventilation for horizontal hydrogen leakage in a cuboid chamber. Ventilations from 30m3/h to 180m3/h were carried out through the rectangular vent. It was shown that the peak concentration of the measuring point is positively correlated with the stagnation pressure and the nozzle diameter. The experimental data are used to verify the analytical model by calculating the effective ventilation time. The study demonstrates that the critical ventilation flow rate can be increased significantly at higher stagnation pressures and larger nozzle diameters. And the discrepancy of critical ventilation flow rates under different nozzle diameters will be enhanced with the increase of stagnation pressure. For the stagnation pressure of 0.4MPa, the critical ventilation flow rate under 4mm nozzle even increases by 52% relative to the 2mm nozzle.
- 6 September 2023
- Published by MDPI AG in Preprints.org
Open AccessAnalytical Model of Critical Ventilation Flow Rate for Accidental Hydrogen Leakage in a Confined Space
The determination of critical ventilation flow rate is significant for the risk control and the standard development during accidental hydrogen leakage in a confined space with hydrogen-related equipment. In this paper, an analytical model for calculating critical ventilation flow rate was proposed through the quantification and constraint solution of ventilation effect and ventilation cost. The experimental method was used to investigate the effects of nozzle diameter and stagnation pressure on diffusion and ventilation for horizontal hydrogen leakage in a cuboid chamber. Ventilations from 30m3/h to 180m3/h were carried out through the rectangular vent. It was shown that the peak concentration of the measuring point is positively correlated with the stagnation pressure and the nozzle diameter. The experimental data are used to verify the analytical model by calculating the effective ventilation time. The study demonstrates that the critical ventilation flow rate can be increased significantly at higher stagnation pressures and larger nozzle diameters. And the discrepancy of critical ventilation flow rates under different nozzle diameters will be enhanced with the increase of stagnation pressure. For the stagnation pressure of 0.4MPa, the critical ventilation flow rate under 4mm nozzle even increases by 52% relative to the 2mm nozzle.