Wenchao Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenchao Guo has a total of 167 co-authors. Here are the top co-authors by number of shared publications:
- Ling Zhang
DAMO Academy, Alibaba Group, Washington DC, USA
3 shared publications - Jian Zhou
Department of Radiology, State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
2 shared publications - Le Lu
DAMO Academy, Alibaba Group, New York, NY
2 shared publications - Yingda Xia
Hupan Lab, Hangzhou, China
2 shared publications Alan L. Yuille
Department of Computer Science, Johns Hopkins University, Baltimore, USA
1 shared publication- Bo Bai
School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication
Latest Publications
- Open Access
- 21 April 2026
- Published by Elsevier in Annals of Oncology
- Vol. 37 (8) , 1144-1156
Colorectal cancer detection using noncontrast CT and deep learning: a multicenter and international cohort study
- 21 April 2026
- Published by Elsevier in Annals of Oncology
- Vol. 37 (8) , 1144-1156
Open AccessColorectal cancer detection using noncontrast CT and deep learning: a multicenter and international cohort study
- Top Cited PapersOpen Access
- 20 August 2025
- Published by Springer Nature in Nature Medicine
- Vol. 31 (11) , 3832-3844
AI-based diagnosis of acute aortic syndrome from noncontrast CT
The accurate and timely diagnosis of acute aortic syndrome (AAS) in patients presenting with acute chest pain remains a clinical challenge. Aortic computed tomography (CT) angiography is the imaging protocol of choice in patients with suspected AAS. However, due to economic and workflow constraints in China, the majority of suspected patients initially undergo noncontrast CT as the initial imaging testing, and CT angiography is reserved for those at higher risk. Although noncontrast CT can reveal specific signs indicative of AAS, its diagnostic efficacy when used alone has not been well characterized. Here we present an artificial intelligence-based warning system, iAorta, using noncontrast CT for AAS identification in China, which demonstrates remarkably high accuracy and provides clinicians with interpretable warnings. iAorta was evaluated through a comprehensive step-wise study. In the multicenter retrospective study (n = 20,750), iAorta achieved a mean area under the receiver operating curve of 0.958 (95% confidence interval 0.950–0.967). In the large-scale real-world study (n = 137,525), iAorta demonstrated consistently high performance across various noncontrast CT protocols, achieving a sensitivity of 0.913–0.942 and a specificity of 0.991–0.993. In the prospective comparative study (n = 13,846), iAorta demonstrated the capability to significantly shorten the time to correct diagnostic pathway for patients with initial false suspicion from an average of 219.7 (115–325) min to 61.6 (43–89) min. Furthermore, for the prospective pilot deployment that we conducted, iAorta correctly identified 21 out of 22 patients with AAS among 15,584 consecutive patients presenting with acute chest pain and under noncontrast CT protocol in the emergency department. For these 21 AAS-positive patients, the average time to diagnosis was 102.1 (75–133) min. Finally, iAorta may help prevent delayed or missed diagnoses of AAS in settings where noncontrast CT remains the only feasible initial imaging modality—such as in resource-limited regions or in patients who cannot receive, or did not receive, intravenous contrast.
- 20 August 2025
- Published by Springer Nature in Nature Medicine
- Vol. 31 (11) , 3832-3844
Top Cited PapersOpen AccessAI-based diagnosis of acute aortic syndrome from noncontrast CT
The accurate and timely diagnosis of acute aortic syndrome (AAS) in patients presenting with acute chest pain remains a clinical challenge. Aortic computed tomography (CT) angiography is the imaging protocol of choice in patients with suspected AAS. However, due to economic and workflow constraints in China, the majority of suspected patients initially undergo noncontrast CT as the initial imaging testing, and CT angiography is reserved for those at higher risk. Although noncontrast CT can reveal specific signs indicative of AAS, its diagnostic efficacy when used alone has not been well characterized. Here we present an artificial intelligence-based warning system, iAorta, using noncontrast CT for AAS identification in China, which demonstrates remarkably high accuracy and provides clinicians with interpretable warnings. iAorta was evaluated through a comprehensive step-wise study. In the multicenter retrospective study (n = 20,750), iAorta achieved a mean area under the receiver operating curve of 0.958 (95% confidence interval 0.950–0.967). In the large-scale real-world study (n = 137,525), iAorta demonstrated consistently high performance across various noncontrast CT protocols, achieving a sensitivity of 0.913–0.942 and a specificity of 0.991–0.993. In the prospective comparative study (n = 13,846), iAorta demonstrated the capability to significantly shorten the time to correct diagnostic pathway for patients with initial false suspicion from an average of 219.7 (115–325) min to 61.6 (43–89) min. Furthermore, for the prospective pilot deployment that we conducted, iAorta correctly identified 21 out of 22 patients with AAS among 15,584 consecutive patients presenting with acute chest pain and under noncontrast CT protocol in the emergency department. For these 21 AAS-positive patients, the average time to diagnosis was 102.1 (75–133) min. Finally, iAorta may help prevent delayed or missed diagnoses of AAS in settings where noncontrast CT remains the only feasible initial imaging modality—such as in resource-limited regions or in patients who cannot receive, or did not receive, intravenous contrast.
- Top Cited PapersOpen Access
- 24 June 2025
- Published by Springer Nature in Nature Medicine
- Vol. 31 (9) , 3011-3019
AI-based large-scale screening of gastric cancer from noncontrast CT imaging
Early detection through screening is critical for reducing gastric cancer (GC) mortality. However, in most high-prevalence regions, large-scale screening remains challenging due to limited resources, low compliance and suboptimal detection rate of upper endoscopic screening. Therefore, there is an urgent need for more efficient screening protocols. Noncontrast computed tomography (CT), routinely performed for clinical purposes, presents a promising avenue for large-scale designed or opportunistic screening. Here we developed the Gastric Cancer Risk Assessment Procedure with Artificial Intelligence (GRAPE), leveraging noncontrast CT and deep learning to identify GC. Our study comprised three phases. First, we developed GRAPE using a cohort from 2 centers in China (3,470 GC and 3,250 non-GC cases) and validated its performance on an internal validation set (1,298 cases, area under curve = 0.970) and an independent external cohort from 16 centers (18,160 cases, area under curve = 0.927). Subgroup analysis showed that the detection rate of GRAPE increased with advancing T stage but was independent of tumor location. Next, we compared the interpretations of GRAPE with those of radiologists and assessed its potential in assisting diagnostic interpretation. Reader studies demonstrated that GRAPE significantly outperformed radiologists, improving sensitivity by 21.8% and specificity by 14.0%, particularly in early-stage GC. Finally, we evaluated GRAPE in real-world opportunistic screening using 78,593 consecutive noncontrast CT scans from a comprehensive cancer center and 2 independent regional hospitals. GRAPE identified persons at high risk with GC detection rates of 24.5% and 17.7% in 2 regional hospitals, with 23.2% and 26.8% of detected cases in T1/T2 stage. Additionally, GRAPE detected GC cases that radiologists had initially missed, enabling earlier diagnosis of GC during follow-up for other diseases. In conclusion, GRAPE demonstrates strong potential for large-scale GC screening, offering a feasible and effective approach for early detection. ClinicalTrials.gov registration: NCT06614179 .
- 24 June 2025
- Published by Springer Nature in Nature Medicine
- Vol. 31 (9) , 3011-3019
Top Cited PapersOpen AccessAI-based large-scale screening of gastric cancer from noncontrast CT imaging
Early detection through screening is critical for reducing gastric cancer (GC) mortality. However, in most high-prevalence regions, large-scale screening remains challenging due to limited resources, low compliance and suboptimal detection rate of upper endoscopic screening. Therefore, there is an urgent need for more efficient screening protocols. Noncontrast computed tomography (CT), routinely performed for clinical purposes, presents a promising avenue for large-scale designed or opportunistic screening. Here we developed the Gastric Cancer Risk Assessment Procedure with Artificial Intelligence (GRAPE), leveraging noncontrast CT and deep learning to identify GC. Our study comprised three phases. First, we developed GRAPE using a cohort from 2 centers in China (3,470 GC and 3,250 non-GC cases) and validated its performance on an internal validation set (1,298 cases, area under curve = 0.970) and an independent external cohort from 16 centers (18,160 cases, area under curve = 0.927). Subgroup analysis showed that the detection rate of GRAPE increased with advancing T stage but was independent of tumor location. Next, we compared the interpretations of GRAPE with those of radiologists and assessed its potential in assisting diagnostic interpretation. Reader studies demonstrated that GRAPE significantly outperformed radiologists, improving sensitivity by 21.8% and specificity by 14.0%, particularly in early-stage GC. Finally, we evaluated GRAPE in real-world opportunistic screening using 78,593 consecutive noncontrast CT scans from a comprehensive cancer center and 2 independent regional hospitals. GRAPE identified persons at high risk with GC detection rates of 24.5% and 17.7% in 2 regional hospitals, with 23.2% and 26.8% of detected cases in T1/T2 stage. Additionally, GRAPE detected GC cases that radiologists had initially missed, enabling earlier diagnosis of GC during follow-up for other diseases. In conclusion, GRAPE demonstrates strong potential for large-scale GC screening, offering a feasible and effective approach for early detection. ClinicalTrials.gov registration: NCT06614179 .
- Top Cited PapersOpen Access
- 20 November 2023
- Published by Springer Nature in Nature Medicine
- Vol. 29 (12) , 3033-3043
Large-scale pancreatic cancer detection via non-contrast CT and deep learning
Pancreatic ductal adenocarcinoma (PDAC), the most deadly solid malignancy, is typically detected late and at an inoperable stage. Early or incidental detection is associated with prolonged survival, but screening asymptomatic individuals for PDAC using a single test remains unfeasible due to the low prevalence and potential harms of false positives. Non-contrast computed tomography (CT), routinely performed for clinical indications, offers the potential for large-scale screening, however, identification of PDAC using non-contrast CT has long been considered impossible. Here, we develop a deep learning approach, pancreatic cancer detection with artificial intelligence (PANDA), that can detect and classify pancreatic lesions with high accuracy via non-contrast CT. PANDA is trained on a dataset of 3,208 patients from a single center. PANDA achieves an area under the receiver operating characteristic curve (AUC) of 0.986–0.996 for lesion detection in a multicenter validation involving 6,239 patients across 10 centers, outperforms the mean radiologist performance by 34.1% in sensitivity and 6.3% in specificity for PDAC identification, and achieves a sensitivity of 92.9% and specificity of 99.9% for lesion detection in a real-world multi-scenario validation consisting of 20,530 consecutive patients. Notably, PANDA utilized with non-contrast CT shows non-inferiority to radiology reports (using contrast-enhanced CT) in the differentiation of common pancreatic lesion subtypes. PANDA could potentially serve as a new tool for large-scale pancreatic cancer screening.
- 20 November 2023
- Published by Springer Nature in Nature Medicine
- Vol. 29 (12) , 3033-3043
Top Cited PapersOpen AccessLarge-scale pancreatic cancer detection via non-contrast CT and deep learning
Pancreatic ductal adenocarcinoma (PDAC), the most deadly solid malignancy, is typically detected late and at an inoperable stage. Early or incidental detection is associated with prolonged survival, but screening asymptomatic individuals for PDAC using a single test remains unfeasible due to the low prevalence and potential harms of false positives. Non-contrast computed tomography (CT), routinely performed for clinical indications, offers the potential for large-scale screening, however, identification of PDAC using non-contrast CT has long been considered impossible. Here, we develop a deep learning approach, pancreatic cancer detection with artificial intelligence (PANDA), that can detect and classify pancreatic lesions with high accuracy via non-contrast CT. PANDA is trained on a dataset of 3,208 patients from a single center. PANDA achieves an area under the receiver operating characteristic curve (AUC) of 0.986–0.996 for lesion detection in a multicenter validation involving 6,239 patients across 10 centers, outperforms the mean radiologist performance by 34.1% in sensitivity and 6.3% in specificity for PDAC identification, and achieves a sensitivity of 92.9% and specificity of 99.9% for lesion detection in a real-world multi-scenario validation consisting of 20,530 consecutive patients. Notably, PANDA utilized with non-contrast CT shows non-inferiority to radiology reports (using contrast-enhanced CT) in the differentiation of common pancreatic lesion subtypes. PANDA could potentially serve as a new tool for large-scale pancreatic cancer screening.
- Open Access
- 7 March 2022
- Published by Hindawi Limited in Shock and Vibration
- Vol. 2022, 1-14
Influence of Misalignment on Beveloid Gear Tooth Contact and Dynamic Characteristics in Transfer Case Transmission of AWD Vehicle
Beveloid gears are usually employed to transfer motion of small shaft angle, but the assembly errors or misalignment can affect the gear tooth contact and dynamic performance. A dynamic model and tooth contact analysis model of the intersecting beveloid gear pair are established, the defects of the theoretical tooth surface in the meshing are analyzed, and a microgeometry modification method to improve the meshing performance is proposed. At the same time, the effects of system misalignment and manufacturing errors on its meshing characteristics are considered. By studying the sensitivity of the static and dynamic characteristics of beveloid gear on different misalignment components, the influence laws of misalignment on the contact pattern, transmission error, mesh stiffness, and dynamic excitation force are obtained, which give suggestions for tooth surface modification and support structural stiffness design of beveloid gear with a good NVH performance.
- 7 March 2022
- Published by Hindawi Limited in Shock and Vibration
- Vol. 2022, 1-14
Open AccessInfluence of Misalignment on Beveloid Gear Tooth Contact and Dynamic Characteristics in Transfer Case Transmission of AWD Vehicle
Beveloid gears are usually employed to transfer motion of small shaft angle, but the assembly errors or misalignment can affect the gear tooth contact and dynamic performance. A dynamic model and tooth contact analysis model of the intersecting beveloid gear pair are established, the defects of the theoretical tooth surface in the meshing are analyzed, and a microgeometry modification method to improve the meshing performance is proposed. At the same time, the effects of system misalignment and manufacturing errors on its meshing characteristics are considered. By studying the sensitivity of the static and dynamic characteristics of beveloid gear on different misalignment components, the influence laws of misalignment on the contact pattern, transmission error, mesh stiffness, and dynamic excitation force are obtained, which give suggestions for tooth surface modification and support structural stiffness design of beveloid gear with a good NVH performance.