Celine Moede
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Celine Moede has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bernhard A. J. Sobotta
Gerodontology Section, Department of Prosthetic Dentistry and Materials Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany
2 shared publications - Ina Nitschke
Gerodontology Section, Department of Prosthetic Dentistry and Materials Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany
2 shared publications - Julia Jockusch
Department of Obstetrics and Gynecology, University Hospital Bern, University of Bern, 3010 Bern, Switzerland
2 shared publications - Werner Hopfenmüller
Institute of Biometry and Clinical Epidemiology, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, 10117 Berlin, Germany
2 shared publications - Andreas Koenig
Department of Dental Prosthetics and Materials Science, Leipzig University, 04103 Leipzig, Germany
1 shared publication - Andreas Koenig
Materials Science Section, Department of Prosthetic Dentistry and Materials Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany
1 shared publication
Latest Publications
- Open Access
- 15 April 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (8) , 2723
An Evaluation of Reference Bite Force Values: Investigating the Relationship Between Dental Prosthetic Restoration and Bite Force in a Cross-Sectional Study
Objectives: This study aimed to establish reference values for bite force in individuals with various prosthetic restorations and to examine the relationship between prosthetic treatment groups (PTGs) and bite force as an indicator of masticatory muscle function. Materials and Methods: In a cross-sectional study from November 2021 to March 2023, 198 participants aged 18 to 95 years were recruited from multiple dental and geriatric centers. The participants were assigned to seven PTGs based on their dental and prosthetic statuses. Bite force was measured using the Occlusal Force Meter GM10, with three recordings on each side of the jaw, and analyzed using ANOVA. Results: The bite force decreased with fewer teeth and the transition from fixed to removable dentures. Fully dentate participants exhibited the highest bite forces, differing significantly from the other groups (p < 0.001). For the fully dentate individuals (547 ± 240 N), the bite force decreased progressively with the extent of prosthetic restoration, reaching 55 ± 45 N in edentulous individuals with complete dentures in both jaws. However, edentulous participants with two interforaminal implants demonstrated higher bite forces than those with partial dentures. Conclusions: Bite force is significantly impacted by prosthetic restoration type. Fully dentate individuals have the highest bite forces, while edentulous patients with implant-supported dentures also show considerable bite forces, similar to those with partial dentures.
- 15 April 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (8) , 2723
Open AccessAn Evaluation of Reference Bite Force Values: Investigating the Relationship Between Dental Prosthetic Restoration and Bite Force in a Cross-Sectional Study
Objectives: This study aimed to establish reference values for bite force in individuals with various prosthetic restorations and to examine the relationship between prosthetic treatment groups (PTGs) and bite force as an indicator of masticatory muscle function. Materials and Methods: In a cross-sectional study from November 2021 to March 2023, 198 participants aged 18 to 95 years were recruited from multiple dental and geriatric centers. The participants were assigned to seven PTGs based on their dental and prosthetic statuses. Bite force was measured using the Occlusal Force Meter GM10, with three recordings on each side of the jaw, and analyzed using ANOVA. Results: The bite force decreased with fewer teeth and the transition from fixed to removable dentures. Fully dentate participants exhibited the highest bite forces, differing significantly from the other groups (p < 0.001). For the fully dentate individuals (547 ± 240 N), the bite force decreased progressively with the extent of prosthetic restoration, reaching 55 ± 45 N in edentulous individuals with complete dentures in both jaws. However, edentulous participants with two interforaminal implants demonstrated higher bite forces than those with partial dentures. Conclusions: Bite force is significantly impacted by prosthetic restoration type. Fully dentate individuals have the highest bite forces, while edentulous patients with implant-supported dentures also show considerable bite forces, similar to those with partial dentures.
- Open Access
- 21 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (23) , 3498
Validation of a New Measuring Instrument for the Assessment of Bite Force
Background: this study aims to validate two occlusal-force-measuring devices by comparing them to a universal testing machine and assessing their reliability across various dental and prosthetic groups. The research comprised two parts: part 1 assessed the measurement accuracy of the Occlusal Force Meter GM 10® (OFM) (Morita, Nagano Keiki, Higashimagome, Ohta-ku, Tokyo, Japan) and a prototype (PRO) by comparing them to a calibrated universal testing machine (ZWICK). Part 2 involved analyzing the devices’ reliability based on clinical bite force measurements from study participants. Results: both devices become more accurate and reliable compared to the ZWICK over time of usage. Additionally, higher deviation from the ZWICK can be observed for higher values of forces applied and vice versa for both devices. The PRO’s intraoral alignment influences its mean values compared to the OFM in different dental and prosthetic groups. Conclusion: both devices had limitations and required quadratic function calibration, making them suitable only for progression measurements. The study concludes that both the OFM and PRO devices can measure occlusal forces with improved accuracy over time. Intraoral alignment should be considered. Their easy-to-use clinical application would allow a more widespread use of masticatory function diagnosis, which could indicate the need for treatment and improve treatment planning.
- 21 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (23) , 3498
Open AccessValidation of a New Measuring Instrument for the Assessment of Bite Force
Background: this study aims to validate two occlusal-force-measuring devices by comparing them to a universal testing machine and assessing their reliability across various dental and prosthetic groups. The research comprised two parts: part 1 assessed the measurement accuracy of the Occlusal Force Meter GM 10® (OFM) (Morita, Nagano Keiki, Higashimagome, Ohta-ku, Tokyo, Japan) and a prototype (PRO) by comparing them to a calibrated universal testing machine (ZWICK). Part 2 involved analyzing the devices’ reliability based on clinical bite force measurements from study participants. Results: both devices become more accurate and reliable compared to the ZWICK over time of usage. Additionally, higher deviation from the ZWICK can be observed for higher values of forces applied and vice versa for both devices. The PRO’s intraoral alignment influences its mean values compared to the OFM in different dental and prosthetic groups. Conclusion: both devices had limitations and required quadratic function calibration, making them suitable only for progression measurements. The study concludes that both the OFM and PRO devices can measure occlusal forces with improved accuracy over time. Intraoral alignment should be considered. Their easy-to-use clinical application would allow a more widespread use of masticatory function diagnosis, which could indicate the need for treatment and improve treatment planning.