Muhammad Ali Siddiqui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Muhammad Ali Siddiqui has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
Ali Dad Chandio
Computational and Experimental Materials Innovation Group (CEMIG), Department of Metallurgical Engineering, NED University of Engineering and Technology, Karachi, Pakistan
2 shared publicationsIhsan Ullah
Zhejiang Engineering Research Center for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, People’s Republic of China
2 shared publicationsJinping Xiong
2 shared publicationsJunxiu Chen
2 shared publicationsNimra Iqbal
Computational and Experimental Materials Innovation Group (CEMIG), Department of Metallurgical Engineering, NED University of Engineering and Technology, Karachi, Pakistan
2 shared publications- Shakir Hussain Koondhar
College of Materials Science and Engineering, Beijing University of Chemical Technology Beijing China
2 shared publications
Latest Publications
- 3 November 2026
- Published by SAGE Publications in Bio-Medical Materials and Engineering
Review on Bio-HEA-based orthopedic implants: Stress shielding, elastic modulus, and the role of mathematical modeling
Background: Bio-inspired high-entropy alloys (Bio-HEAs) are emerging as materials for orthopedic implants because of their high strength, corrosion resistance, compositional flexibility, and biocompatibility. Their tunable mechanical properties may reduce elastic mismatch with bone and mitigate stress shielding and implant loosening. Objective: This review evaluates Bio-HEAs for orthopedic applications, emphasizing elastic modulus tailoring, stress-shielding mitigation, microstructural control, biological response, and mathematical modeling. Methods: Literature on Bio-HEAs for biomedical applications was reviewed, focusing on composition–structure–property relationships, elastic modulus, phase stability, biological response, and computational approaches. Experimental findings were considered alongside molecular dynamics (MD), continuum elasticity, partial differential equation (PDE)-based approaches, and finite element method (FEM) simulations. Results: Reported Bio-HEAs exhibit elastic moduli ranging approximately from 10 to 30 GPa, providing opportunities to reduce mechanical mismatch with cortical bone. Atomic size mismatch, lattice distortion, phase constitution, and microstructural features influence elastic behavior. MD, continuum models, and FEM provide complementary insights across length scales, while integrated multiscale approaches can improve implant-level predictions and support patient-specific design. Conclusion: Bio-HEAs offer potential for mechanically compatible orthopedic implants. Integrating materials design with multiscale mathematical modeling may enable improved control of elastic behavior, stress distribution, and implant performance, although experimental validation and clinically relevant modeling are required.
- 3 November 2026
- Published by SAGE Publications in Bio-Medical Materials and Engineering
Review on Bio-HEA-based orthopedic implants: Stress shielding, elastic modulus, and the role of mathematical modeling
Background: Bio-inspired high-entropy alloys (Bio-HEAs) are emerging as materials for orthopedic implants because of their high strength, corrosion resistance, compositional flexibility, and biocompatibility. Their tunable mechanical properties may reduce elastic mismatch with bone and mitigate stress shielding and implant loosening. Objective: This review evaluates Bio-HEAs for orthopedic applications, emphasizing elastic modulus tailoring, stress-shielding mitigation, microstructural control, biological response, and mathematical modeling. Methods: Literature on Bio-HEAs for biomedical applications was reviewed, focusing on composition–structure–property relationships, elastic modulus, phase stability, biological response, and computational approaches. Experimental findings were considered alongside molecular dynamics (MD), continuum elasticity, partial differential equation (PDE)-based approaches, and finite element method (FEM) simulations. Results: Reported Bio-HEAs exhibit elastic moduli ranging approximately from 10 to 30 GPa, providing opportunities to reduce mechanical mismatch with cortical bone. Atomic size mismatch, lattice distortion, phase constitution, and microstructural features influence elastic behavior. MD, continuum models, and FEM provide complementary insights across length scales, while integrated multiscale approaches can improve implant-level predictions and support patient-specific design. Conclusion: Bio-HEAs offer potential for mechanically compatible orthopedic implants. Integrating materials design with multiscale mathematical modeling may enable improved control of elastic behavior, stress distribution, and implant performance, although experimental validation and clinically relevant modeling are required.
- 29 August 2026
- Published by Elsevier in Electrochimica Acta
- Vol. 578
Effect of pH on corrosion behavior of hastelloy C-276 in NH₄Cl solution
- 29 August 2026
- Published by Elsevier in Electrochimica Acta
- Vol. 578
Effect of pH on corrosion behavior of hastelloy C-276 in NH₄Cl solution
- 5 August 2026
- Published by Wiley in Chemistry – An Asian Journal
- Vol. 21 (15)
Electrochemical Study on Passive Behavior of Hastelloy C‐276 in Ammonium Chloride Solution With Sodium Thiosulphate
The corrosion behavior of C‐276 alloy in 5 M ammonium chloride solution containing different concentrations of sodium thiosulfate (0–0.4 M) was investigated using Potentiodynamic polarization, cyclic voltammetry, electrochemical impedance spectroscopy and Mott‐Schottky analysis. Sodium thiosulphate increasing shows the increasing corrosion current density i corr and passive current density, pitting potential also shift to lower values shows degradation of passive film. Cv analysis revealed anodic peak shifts to lower potentials with increasing thiosulfate concentration, suggested easier passive film transformation. EIS results showed a decrease in charge transfer resistance and an increase in capacitance, showed reduced film stability and increased surface heterogeneity. Mott‐Schottky analysis demonstrated both n‐type and p‐type semiconductor behavior, with increasing donor and acceptor densities confirmed higher defect concentration in the passive film. The passive film is interpreted as a multi‐component oxide/hydroxide layer consisting of a Cr rich inner barrier layer and an outer hydroxide layer containing Mo and Ni. The corrosion mechanism is explained using the Point Defect Model (PDM), where defect generation, migration, and accumulation lead to passive film breakdown and localized corrosion. The synergistic effect of chloride and thiosulfate ions accelerates passive film degradation and enhances corrosion susceptibility of the alloy.
- 5 August 2026
- Published by Wiley in Chemistry – An Asian Journal
- Vol. 21 (15)
Electrochemical Study on Passive Behavior of Hastelloy C‐276 in Ammonium Chloride Solution With Sodium Thiosulphate
The corrosion behavior of C‐276 alloy in 5 M ammonium chloride solution containing different concentrations of sodium thiosulfate (0–0.4 M) was investigated using Potentiodynamic polarization, cyclic voltammetry, electrochemical impedance spectroscopy and Mott‐Schottky analysis. Sodium thiosulphate increasing shows the increasing corrosion current density i corr and passive current density, pitting potential also shift to lower values shows degradation of passive film. Cv analysis revealed anodic peak shifts to lower potentials with increasing thiosulfate concentration, suggested easier passive film transformation. EIS results showed a decrease in charge transfer resistance and an increase in capacitance, showed reduced film stability and increased surface heterogeneity. Mott‐Schottky analysis demonstrated both n‐type and p‐type semiconductor behavior, with increasing donor and acceptor densities confirmed higher defect concentration in the passive film. The passive film is interpreted as a multi‐component oxide/hydroxide layer consisting of a Cr rich inner barrier layer and an outer hydroxide layer containing Mo and Ni. The corrosion mechanism is explained using the Point Defect Model (PDM), where defect generation, migration, and accumulation lead to passive film breakdown and localized corrosion. The synergistic effect of chloride and thiosulfate ions accelerates passive film degradation and enhances corrosion susceptibility of the alloy.
- 31 July 2026
- Published by EDP Sciences in Metallurgical Research & Technology
- Vol. 123 (5) , 515
Influence of minor Fe addition on the corrosion behavior of Zn–6Cu alloys for biodegradable implant Applications
This study investigates the effect of minor iron (Fe) additions on the corrosion behavior of Zn–6Cu alloys for potential use in biodegradable implant applications. Alloys with compositions Zn–6Cu– x Fe ( x = 0.16 and 0.22 wt.%) were synthesized via induction melting, with pure Zn as a reference. Phase identification was carried out via X-ray diffraction (XRD). Electrochemical measurements in physiological saline solution were conducted to assess charge transfer resistance, double-layer capacitance, corrosion current density, and corrosion rate. -XRD confirmed the presence of η-Zn, CuZn 5 , and FeZn 13 phases, indicating that Fe participates in the formation of distinct intermetallic compounds. Results of potentiodynamic polarization and electrochemical impedance spectroscopy indicate that Fe addition significantly influences corrosion mechanisms. The Zn–6Cu–0.16Fe alloy demonstrated the lowest corrosion rate and highest impedance among the studied samples, indicating suppressed electrochemical activity and enhanced corrosion resistance without forming a passive film. In contrast, the Zn–6Cu–0.22Fe alloy exhibited a transient passive film accompanied by a measurable pitting potential, suggesting a transition from uniform corrosion to localized attack at higher Fe content. Both Fe-containing alloys outperformed pure Zn in corrosion performance; however, the alloy with 0.16 wt.% Fe proved most effective in achieving controlled and uniform degradation in physiological saline. These results underscore the importance of precise Fe addition in Zn–Cu alloys for biodegradable implants, where a lower Fe content improves corrosion resistance by inhibiting active dissolution, while higher Fe content may promote passivation but with an increased risk of localized corrosion in chloride-rich environments.
- 31 July 2026
- Published by EDP Sciences in Metallurgical Research & Technology
- Vol. 123 (5) , 515
Influence of minor Fe addition on the corrosion behavior of Zn–6Cu alloys for biodegradable implant Applications
This study investigates the effect of minor iron (Fe) additions on the corrosion behavior of Zn–6Cu alloys for potential use in biodegradable implant applications. Alloys with compositions Zn–6Cu– x Fe ( x = 0.16 and 0.22 wt.%) were synthesized via induction melting, with pure Zn as a reference. Phase identification was carried out via X-ray diffraction (XRD). Electrochemical measurements in physiological saline solution were conducted to assess charge transfer resistance, double-layer capacitance, corrosion current density, and corrosion rate. -XRD confirmed the presence of η-Zn, CuZn 5 , and FeZn 13 phases, indicating that Fe participates in the formation of distinct intermetallic compounds. Results of potentiodynamic polarization and electrochemical impedance spectroscopy indicate that Fe addition significantly influences corrosion mechanisms. The Zn–6Cu–0.16Fe alloy demonstrated the lowest corrosion rate and highest impedance among the studied samples, indicating suppressed electrochemical activity and enhanced corrosion resistance without forming a passive film. In contrast, the Zn–6Cu–0.22Fe alloy exhibited a transient passive film accompanied by a measurable pitting potential, suggesting a transition from uniform corrosion to localized attack at higher Fe content. Both Fe-containing alloys outperformed pure Zn in corrosion performance; however, the alloy with 0.16 wt.% Fe proved most effective in achieving controlled and uniform degradation in physiological saline. These results underscore the importance of precise Fe addition in Zn–Cu alloys for biodegradable implants, where a lower Fe content improves corrosion resistance by inhibiting active dissolution, while higher Fe content may promote passivation but with an increased risk of localized corrosion in chloride-rich environments.
- 9 January 2026
- Published by EDP Sciences in Metallurgical Research & Technology
- Vol. 123 (1) , 102
Effects of prolonged retrogression and re-aging (RRA) heat treatment on the corrosion and electrochemical behavior of AA7075 alloy
Aluminum alloy AA7075 is prized for its high strength-to-weight ratio, but its corrosion resistance under prolonged exposure remains a critical concern. This study investigates the effects of extended retrogression and re-aging (RRA) heat treatment on the corrosion and electrochemical behavior of AA7075 alloy. The alloy underwent retrogression at 180 °C, 240 °C, and 320 °C for 12 h, followed by re-aging at 100 °C for 10 h. Corrosion performance was evaluated in a 3.5% NaCl solution, analyzing corrosion current density, corrosion potential, corrosion rate, charge transfer resistance, and double-layer capacitance. Results revealed that retrogression temperature significantly influenced corrosion resistance. The alloy treated at 240 °C exhibited optimal performance, with a corrosion current density of 3.1 μA/cm 2 , charge transfer resistance of 2697 Ω cm 2 , and double-layer capacitance of 1.42 μF/cm 2 . XRD analysis identified beneficial precipitates, including MgZn 2 , Al 2 CuMg, and Al 50 Mg 48 Cu, along with optimized dislocation density (12.47 lines/nm 2 ), crystallite size (28.63 nm), and microstrain (0.9). These factors contributed to enhanced corrosion resistance by influencing precipitate nucleation and growth. The findings highlight the importance of precise RRA heat treatment parameters in tailoring the alloy’s microstructure for improved corrosion resistance, offering valuable insights for engineering applications in corrosive environments. This study provides a foundation for optimizing AA7075 alloy performance in real-world scenarios.
- 9 January 2026
- Published by EDP Sciences in Metallurgical Research & Technology
- Vol. 123 (1) , 102
Effects of prolonged retrogression and re-aging (RRA) heat treatment on the corrosion and electrochemical behavior of AA7075 alloy
Aluminum alloy AA7075 is prized for its high strength-to-weight ratio, but its corrosion resistance under prolonged exposure remains a critical concern. This study investigates the effects of extended retrogression and re-aging (RRA) heat treatment on the corrosion and electrochemical behavior of AA7075 alloy. The alloy underwent retrogression at 180 °C, 240 °C, and 320 °C for 12 h, followed by re-aging at 100 °C for 10 h. Corrosion performance was evaluated in a 3.5% NaCl solution, analyzing corrosion current density, corrosion potential, corrosion rate, charge transfer resistance, and double-layer capacitance. Results revealed that retrogression temperature significantly influenced corrosion resistance. The alloy treated at 240 °C exhibited optimal performance, with a corrosion current density of 3.1 μA/cm 2 , charge transfer resistance of 2697 Ω cm 2 , and double-layer capacitance of 1.42 μF/cm 2 . XRD analysis identified beneficial precipitates, including MgZn 2 , Al 2 CuMg, and Al 50 Mg 48 Cu, along with optimized dislocation density (12.47 lines/nm 2 ), crystallite size (28.63 nm), and microstrain (0.9). These factors contributed to enhanced corrosion resistance by influencing precipitate nucleation and growth. The findings highlight the importance of precise RRA heat treatment parameters in tailoring the alloy’s microstructure for improved corrosion resistance, offering valuable insights for engineering applications in corrosive environments. This study provides a foundation for optimizing AA7075 alloy performance in real-world scenarios.
- 4 December 2025
- Published by Springer Nature in Journal of Failure Analysis and Prevention
- Vol. 26 (1) , 9-16
Failure Analysis of a Locomotive Traction Gear: Metallurgical and Fractographic Insights
- 4 December 2025
- Published by Springer Nature in Journal of Failure Analysis and Prevention
- Vol. 26 (1) , 9-16
Failure Analysis of a Locomotive Traction Gear: Metallurgical and Fractographic Insights
- Open Access
Effect of Hydroxyapatite Post-Treatment on the Corrosion Resistance, Cytocompatibility and Antibacterial Properties of Copper-Containing Micro Arc Oxidation Coatings on Mg Alloy as Oral GBR Membrane Application
Biodegradable magnesium (Mg) alloys hold promising application prospects in the field of guided bone regeneration (GBR) membranes, particularly for oral and maxillofacial applications. However, their corrosion resistance requires further improvement. Additionally, Mg alloys are susceptible to bacterial infection upon implantation, while copper (Cu) is known for its excellent antibacterial properties. Introducing Cu into the micro-arc oxidation (MAO) coating can enhance both the corrosion resistance and antibacterial performance of Mg alloys. However, the sealing effect of such coatings remains suboptimal. Hydroxyapatite (HA), which possesses outstanding bioactivity, is a promising bone substitute material. This study investigates the influence of HA content on the microstructure, corrosion resistance, cytotoxicity, and antibacterial properties of Cu-containing MAO coatings. The results demonstrate that as the HA concentration increases, the corrosion resistance of the composite coating is significantly enhanced. The corrosion rate decreased from 0.32 mm/y for the untreated MAO coating to 0.27 mm/y and 0.23 mm/y for the HA-treated samples with EDTA–Ca concentrations of 125 mmol/L and 175 mmol/L, respectively. Cytotoxicity assessment indicates that the incorporation of an HA layer significantly improves cell compatibility compared to the bare MAO coating. However, the enhanced corrosion resistance provided by the denser HA layer (at 175 mmol/L EDTA–Ca) unfortunately acts as a barrier, limiting the release of antibacterial Cu2+. Among the coatings tested, the one with 125 mmol/L EDTA–Ca exhibited the best overall performance, demonstrating good corrosion resistance, cytocompatibility, and effective antibacterial properties.
Open AccessEffect of Hydroxyapatite Post-Treatment on the Corrosion Resistance, Cytocompatibility and Antibacterial Properties of Copper-Containing Micro Arc Oxidation Coatings on Mg Alloy as Oral GBR Membrane Application
Biodegradable magnesium (Mg) alloys hold promising application prospects in the field of guided bone regeneration (GBR) membranes, particularly for oral and maxillofacial applications. However, their corrosion resistance requires further improvement. Additionally, Mg alloys are susceptible to bacterial infection upon implantation, while copper (Cu) is known for its excellent antibacterial properties. Introducing Cu into the micro-arc oxidation (MAO) coating can enhance both the corrosion resistance and antibacterial performance of Mg alloys. However, the sealing effect of such coatings remains suboptimal. Hydroxyapatite (HA), which possesses outstanding bioactivity, is a promising bone substitute material. This study investigates the influence of HA content on the microstructure, corrosion resistance, cytotoxicity, and antibacterial properties of Cu-containing MAO coatings. The results demonstrate that as the HA concentration increases, the corrosion resistance of the composite coating is significantly enhanced. The corrosion rate decreased from 0.32 mm/y for the untreated MAO coating to 0.27 mm/y and 0.23 mm/y for the HA-treated samples with EDTA–Ca concentrations of 125 mmol/L and 175 mmol/L, respectively. Cytotoxicity assessment indicates that the incorporation of an HA layer significantly improves cell compatibility compared to the bare MAO coating. However, the enhanced corrosion resistance provided by the denser HA layer (at 175 mmol/L EDTA–Ca) unfortunately acts as a barrier, limiting the release of antibacterial Cu2+. Among the coatings tested, the one with 125 mmol/L EDTA–Ca exhibited the best overall performance, demonstrating good corrosion resistance, cytocompatibility, and effective antibacterial properties.
- 20 June 2025
- Published by Springer Nature in Mining, Metallurgy & Exploration
- Vol. 42 (4) , 2379-2385
Affordable and Sustainable Extraction of Copper from Indigenous Sulfide Ore: A Hydrometallurgical and Electrochemical Approach
- 20 June 2025
- Published by Springer Nature in Mining, Metallurgy & Exploration
- Vol. 42 (4) , 2379-2385
Affordable and Sustainable Extraction of Copper from Indigenous Sulfide Ore: A Hydrometallurgical and Electrochemical Approach
- 27 March 2025
- Published by EDP Sciences in Metallurgical Research & Technology
- Vol. 122 (2) , 214
Pilot production and evaluation of mechanical, corrosion, and metallurgical properties of stainless steel-clad rebars
This study thoroughly assesses the mechanical, corrosion, and metallurgical properties of stainless steel-clad rebars for their potential in enhancing construction materials. Using the solid-liquid casting technique, Amreli Steels Limited in Pakistan pilot-produced Austenitic Stainless Steel (ASS)/Carbon Steel (CS) clad rebars. Molten Grade 60 carbon steel (ASTM 615) was cast into red-hot austenitic stainless steel pipes (AISI 316L) both vertically and horizontally. Horizontally cast samples showed significantly improved bonding between stainless steel cladding and carbon steel core after hot-rolling at 1120 °C. While tensile properties generally met ASTM 615M yield strength criteria, they slightly deviated in ultimate tensile strength and percent elongation. Microstructural analysis revealed an austenite phase on the surface side and pearlite/ferrite in the core, yet inherent defects like microcracks and pinholes compromised mechanical performance. Surface hardness measured commendably at 24.6 HRC, declining notably deeper into the rebar. The core region had a hardness of 11.5 HRC, while the interface between stainless steel (SS) layer and core recorded 7.2 HRC. Electrochemical analysis indicated a lower corrosion rate of 0.8 mm/year in SS-clad rebar compared to Grade 60 steel’s 1.20 mm/year, highlighting enhanced corrosion resistance in 3.5% NaCl solution. Additionally, SS-clad rebars exhibited a two-time constant feature [R(Q(R(QR)))] similar to AISI 316L SS, contrasting with Grade 60 steel’s single time constant [R(QR)], suggesting a bi-layer characteristic (inner barrier oxide layer and outer hydroxide layer) in SS-clad Grade 60. Polarization resistance of the barrier layer and capacitance measured 35.07 Ω cm2 and 18.9 mF cm−2, respectively, underscoring favorable passive film properties. This investigation provides crucial insights for optimizing construction materials and addressing corrosion-induced deterioration.
- 27 March 2025
- Published by EDP Sciences in Metallurgical Research & Technology
- Vol. 122 (2) , 214
Pilot production and evaluation of mechanical, corrosion, and metallurgical properties of stainless steel-clad rebars
This study thoroughly assesses the mechanical, corrosion, and metallurgical properties of stainless steel-clad rebars for their potential in enhancing construction materials. Using the solid-liquid casting technique, Amreli Steels Limited in Pakistan pilot-produced Austenitic Stainless Steel (ASS)/Carbon Steel (CS) clad rebars. Molten Grade 60 carbon steel (ASTM 615) was cast into red-hot austenitic stainless steel pipes (AISI 316L) both vertically and horizontally. Horizontally cast samples showed significantly improved bonding between stainless steel cladding and carbon steel core after hot-rolling at 1120 °C. While tensile properties generally met ASTM 615M yield strength criteria, they slightly deviated in ultimate tensile strength and percent elongation. Microstructural analysis revealed an austenite phase on the surface side and pearlite/ferrite in the core, yet inherent defects like microcracks and pinholes compromised mechanical performance. Surface hardness measured commendably at 24.6 HRC, declining notably deeper into the rebar. The core region had a hardness of 11.5 HRC, while the interface between stainless steel (SS) layer and core recorded 7.2 HRC. Electrochemical analysis indicated a lower corrosion rate of 0.8 mm/year in SS-clad rebar compared to Grade 60 steel’s 1.20 mm/year, highlighting enhanced corrosion resistance in 3.5% NaCl solution. Additionally, SS-clad rebars exhibited a two-time constant feature [R(Q(R(QR)))] similar to AISI 316L SS, contrasting with Grade 60 steel’s single time constant [R(QR)], suggesting a bi-layer characteristic (inner barrier oxide layer and outer hydroxide layer) in SS-clad Grade 60. Polarization resistance of the barrier layer and capacitance measured 35.07 Ω cm2 and 18.9 mF cm−2, respectively, underscoring favorable passive film properties. This investigation provides crucial insights for optimizing construction materials and addressing corrosion-induced deterioration.