WCWilliam C. Culp

William C. Culp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William C. Culp has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Changing the Culture: Increasing and Sustaining Anesthesiology Resident Physician Publication Rates

    by William C. Culp, Riley J. Hedin, Daniel W. Watkins, Craig J. Lilie, J. Clint Tippett, Emily H. Garmon, Timothy M. Bittenbinder, Russell K. McAllister

    Academic inquiry is foundational to the advancement of medicine and resident training and must be demonstrated to the Accreditation Council for Graduate Medical Education. Past attempts at increasing publication rates have failed to identify educational best practice models. Our aim was to increase resident publication rates via culture and value changes that are universally implementable, affordable, effective, and sustainable. In 2018, a multifaceted initiative was implemented to shift departmental values and foster a culture of academic productivity. This culture change stressed the value of scientific publication through frequent, consistent messaging from department leaders. In addition, residents were provided the freedom to choose their scholarly activities. In this retrospective cohort innovation, resident authors were identified for 4 academic years before and after the intervention and publication rates were determined (2014-2018 vs 2018-2022). Resident authors and publications per resident per year were compared using descriptive statistics and Student t test. The pre- and postintervention groups included 38 and 37 residents, respectively. Resident-authored publications increased from 7 preintervention to 24 postintervention, representing 343% of baseline. Mean ± SD publications per resident per year similarly increased 357% from 0.183 ± 0.16 to 0.654 ± 0.11 postintervention. Unpaired t test analysis demonstrated a significant difference in total publications per year (P = .002) and authorship rate (P = .003). A multifaceted academic initiative resulted in a threefold increase in resident publication rates. This initiative demonstrates that local advocacy by leaders, freedom of choice for authors, and supportive departmental culture are driving factors in publication rates.

  • Pharyngeal oxygen delivery device sustains manikin lung oxygenation longer than high-flow nasal cannula

    by Jeramie B. Hanson, John R. Williams, Emily H. Garmon, Phillip M. Morris, Russell K. McAllister, Courtney N. Shaver, William C. Culp

    Hypoxemia during a failed airway scenario is life threatening. A dual-lumen pharyngeal oxygen delivery device (PODD) was developed to fit inside a traditional oropharyngeal airway for undisrupted supraglottic oxygenation and gas analysis during laryngoscopy and intubation. We hypothesized that the PODD would provide oxygen as effectively as high-flow nasal cannula (HFNC) while using lower oxygen flow rates. We compared oxygen delivery of the PODD to HFNC in a preoxygenated, apneic manikin lung that approximated an adult functional residual capacity. Four arms were studied: HFNC at 20 and 60 liters per minute (LPM) oxygen, PODD at 10 LPM oxygen, and a control arm with no oxygen flow after initial preoxygenation. Five randomized 20-minute trials were performed for each arm (20 trials total). Descriptive statistics and analysis of variance were used with statistical significance of P < 0.05. Mean oxygen concentrations were statistically different and decreased from 97% as follows: 41 ± 0% for the control, 90 ± 1% for HFNC at 20 LPM, 88 ± 2% for HFNC at 60 LPM, and 97 ± 1% (no change) for the PODD at 10 LPM. Oxygen delivery with the PODD maintained oxygen concentration longer than HFNC in this manikin model at lower flow rates than HFNC.


  • Arterial Cannulation Near-Miss During Jugular Venous Catheterization With Carotid Artery Aneurysm: A Case Report

    by William C. Culp, Michael Beitzel, Shawn Malan, Kelsea C. Wright

    Central venous catheterization is a common procedure that may lead to inadvertent arterial cannulation, potentially causing bleeding, hematoma, stroke or rarely, death. In this near-miss case presentation, an aneurysmal carotid artery was misidentified with ultrasound by a junior resident, nearly leading to placement of a sheath into the artery. This case highlights arterial punctures that still occur even with ultrasound guidance. Further, training inadequacies as well as anatomic, cultural, and production pressure factors led to this potentially highly morbid near-miss. Physician teachers should critically evaluate teaching methods to confirm that trainees are learning skills as intended. (A&A Practice. 2023;17:e01661.)

  • Coronavirus Disease 2019: Anesthesia Machine Circuit Pressure During Use as an Improvised Intensive Care Unit Ventilator

    by Vinh Pham, Le Nguyen, Riley J. Hedin, Courtney Shaver, Kendall A. P. Hammonds, William C. Culp

    BACKGROUND: Use of anesthesia machines as improvised intensive care unit (ICU) ventilators may occur in locations where waste anesthesia gas suction (WAGS) is unavailable. Anecdotal reports suggest as much as 18 cm H2O positive end-expiratory pressure (PEEP) being inadvertently applied under these circumstances, accompanied by inaccurate pressure readings by the anesthesia machine. We hypothesized that resistance within closed anesthesia gas scavenging systems (AGSS) disconnected from WAGS may inadvertently increase circuit pressures. METHODS: An anesthesia machine was connected to an anesthesia breathing circuit, a reference manometer, and a standard bag reservoir to simulate a lung. Ventilation was initiated as follows: volume control, tidal volume (TV) 500 mL, respiratory rate 12, ratio of inspiration to expiration times (I:E) 1:1.9, fraction of inspired oxygen (Fio 2) 1.0, fresh gas flow (FGF) rate 2.0 liters per minute (LPM), and PEEP 0 cm H2O. After engaging the ventilator, PEEP and peak inspiratory pressure (PIP) were measured by the reference manometer and the anesthesia machine display simultaneously. The process was repeated using prescribed PEEP levels of 5, 10, 15, and 20 cm H2O. Measurements were repeated with the WAGS disconnected and then were performed again at FGF of 4, 6, 8, 10, and 15 LPM. This process was completed on 3 anesthesia machines: Dräger Perseus A500, Dräger Apollo, and the GE Avance CS2. Simple linear regression was used to assess differences. RESULTS: Utilizing nonparametric Bland-Altman analysis, the reference and machine manometer measurements of PIP demonstrated median differences of −0.40 cm H2O (95% limits of agreement [LOA], −1.00 to 0.55) for the Dräger Apollo, −0.40 cm H2O (95% LOA, −1.10 to 0.41) for the Dräger Perseus, and 1.70 cm H2O (95% LOA, 0.80-3.00) for the GE Avance CS2. At FGF 2 LPM and PEEP 0 cm H2O with the WAGS disconnected, the Dräger Apollo had a difference in PEEP of 0.02 cm H2O (95% confidence interval [CI], −0.04 to 0.08; P = .53); the Dräger Perseus A500, 2O (95% CI, −0.11 to 0.11; P = 1.00); and the GE Avance CS2, 8.62 cm H2O (95% CI, 8.55-8.69; P < .0001). After removing the hose connected to the AGSS and the visual indicator bag on the GE Avance CS2, the PEEP difference was 0.12 cm H2O (95% CI, 0.059-0.181; P = .0002). CONCLUSIONS: Displayed airway pressure measurements are clinically accurate in the setting of disconnected WAGS. The Dräger Perseus A500 and Apollo with open scavenging systems do not deliver inadvertent continuous positive airway pressure (CPAP) with WAGS disconnected, but the GE Avance CS2 with a closed AGSS does. This increase in airway pressure can be mitigated by the manufacturer’s recommended alterations. Anesthesiologists should be aware of the potential clinically important increases in pressure that may be inadvertently delivered on some anesthesia machines, should the WAGS not be properly connected.


  • Coronavirus Disease 2019: In-Home Isolation Room Construction

    by William C. Culp

    Patient care duties will expose health care workers to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Many are concerned about subsequent household exposure to their families, particularly those family members with high risk of complications or mortality, potentiating additional community spread. Herein is described a temporary isolation room that can be created within a home, thereby decreasing bioburden exposure to family members. The design is simple, expedient, and can be built with locally sourced inexpensive supplies. A viewing and access window facilitates safe family interaction and decreases the emotional costs of isolation while providing a route to pass items as necessary.