MCMélodie Cyr

Mélodie Cyr

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mélodie Cyr has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Shirin A. Enger

    Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montreal, Canada

    4 shared publications
  • Behnaz Behmand

    Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montreal, Canada

    3 shared publications
  • Guillaume St-Jean

    Department of Pathology and Microbiology, Faculty of Veterinary Medicine, University of Montreal, Montreal, Canada

    2 shared publications
  • Joud Babik

    Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montreal, Canada

    2 shared publications
  • Nada Tomic

    Medical Physics Unit Department of Oncology Faculty of Medicine McGill University Montreal QC Canada

    2 shared publications
  • Naim Chabaytah

    Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montreal, Canada

    2 shared publications

Latest Publications

  • Open Access

    Diffusion of the alpha-particle emitting daughters of alpha-DaRT sources in an orthotopic murine model of colorectal adenocarcinoma

    by Mélodie Cyr, Naim Chabaytah, Joud Babik, Behnaz Behmand, Joanna Li, Meghan Papagni, Elliot Wadge, Mirta Dumancic, Guillaume St-Jean, François E. Mercier, et al.

    Alpha-DaRT, an interstitial treatment, uses 224Ra-based diffusing alpha-emitters to treat solid tumors by creating a high-dose region up to 5 mm around the source. However, diffusion lengths (Ldiff) remain uncertain across cancer types, with current estimates from subcutaneous and limited orthotopic models. This study measured the Ldiff in an orthotopic colorectal adenocarcinoma mouse model. HT-29 colorectal adenocarcinoma cells were injected into the rectal submucosa of 38 Nod scid gamma mice. Tumor growth was monitored with 7 T Magnetic Resonance Imaging (MRI). At ~ 5–7 mm, groups included active (n = 20), inert (n = 9), and control (n = 9). Active mice had Alpha-DaRT sources implanted in tumors (n = 15) and rectal muscle (n = 5). Ex-vivo liver tissue (n = 3) was also analyzed. After four days, gamma spectroscopy measured 212Pb activity, and autoradiographs and histopathology assessed Ldiff, tissue damage, and vascularity (H&E, CD-31, CC-3). Ldiff was 0.36–0.84 mm in tumors, 0.30 mm in rectal muscle, and 1.0 mm in liver tissue. 212Pb showed a 50–93% escape probability, with kidneys having the highest activity. Active tumors exhibited more necrosis (p = 0.034) and reduced vascularity. This study provides the first in-vivo Ldiff measurements of Alpha-DaRT in an orthotopic colorectal adenocarcinoma model, highlighting Ldiff variability and the need for optimization based on cancer type.

  • Open Access

    Preclinical magnetic resonance imaging in the presence of Alpha-DaRT seeds: mitigation of metal artifacts

    by Melodie Cyr, David Rudko, Behnaz Behmand, Shirin A Enger, Ives R Levesque

    Objective: Diffusing alpha-emitters radiation therapy (Alpha-DaRT) involves implanting stainless steel seeds containing 70-200 kBq of 224 Ra into solid tumors. The decay of 224 Ra generates alpha particles and short-lived alpha-emitting atoms, which diffuse and deposit absorbed dose up to millimeters from the seed. The investigation of diffusion length from the alpha-emitting daughters is ongoing through magnetic resonance imaging (MRI)-guided pre-clinical in-vivo studies. However, the metallic seeds cause metal artifacts in MRI, distorting signals and degrading images. Overcoming these artifacts is essential for accurate tumor assessment and treatment planning. This study aimed to reduce metal artifacts in images acquired with 7 T preclinical MRI in the presence of Alpha-DaRT seeds using an orthotopic colorectal adenocarcinoma animal model. Approach: Inert seeds were placed in gelatin phantoms and the dorsal cavity of a mouse carcass. For the in-vivo animal model, NOD scid gamma mice with HT-29 colorectal adenocarcinoma tumors (∽5-7 mm) were injected with inert seeds. MRI sequence parameters such as echo and repetition times, slice thickness, and readout bandwidth were tested using the phantom and refined with carcass imaging, leading to in-vivo imaging. Main results: Multiple sequence protocols were tested on gelatin phantoms and compared to the original T 2 w rapid acquisition relaxation enhanced sequence protocol. A T 2 -weighted turbo spin echo sequence reduced metal artifacts in the gelatin phantom from 2.910 ± 0.001 mm to 1.426 ± 0.001 mm in the sagittal reformat, resulting in a 51% reduction. Validation in the mouse carcass confirmed high-quality soft-tissue imaging. In-vivo images with live mice showed a statistically significant reduction (p2 -weighted turbo spin echo protocol effectively minimized metal artifacts from Alpha-DaRT seeds in a colorectal adenocarcinoma animal model, allowing for clearer visualization of seed placement within the tumor and improving the accuracy of pre-clinical studies.

  • Open Access

    Dosimetric evaluation of unlaminated radiochromic films exposed to an Americium‐241 source using measurements and Monte Carlo simulations

    by Mélodie Cyr, Maryam Rahbaran, Nada Tomic, Shirin A. Enger

    Background: Radiochromic GafChromic film models are widely used in clinical settings for quality assurance during cancer treatment planning. Although these films are extensively studied in photon dosimetry, research on their application in α‐particle dosimetry remains limited. With the growing use of α‐particles in cancer therapy, it is important to establish film dosimetry protocols tailored to α‐particles. Unlike photons, α‐particles are charged, have a high linear energy transfer, and induce significantly greater biological damage, highlighting the need for specialized dosimetric approaches. Purpose: This study aimed to evaluate the response of various unlaminated GafChromic film models including EBT3, EBT‐XD, and HD‐V2, irradiated with an 241 Am α‐particle source, with combined experimental film irradiation and Monte Carlo (MC) simulations. Methods: In this study, unlaminated EBT3, EBT‐XD, and HD‐V2 film pieces were irradiated with an 241 Am disk source at various exposure times within a dark box. A detailed comparison was performed across the three film models, focusing on uncertainties and relative dose errors. Film analysis was conducted using a custom Python script, extracting normalized pixel values from the green channel. Additionally, a MC‐based user code was developed using the Geant4 simulation toolkit to model the 241 Am source and calculate the dose rates in the active layers of the films and in water. The mean dose rates were also calculated in a 1 mm diameter region of interest. These simulated dose rates were employed to convert film exposure times into absorbed doses for both the active layers and water, establishing a reference dosimetry protocol for α‐particles across the three radiochromic GafChromic film models. Results: The mean dose rates within a 1 mm diameter circular region of interest in the active layers of the three unlaminated GafChromic film models were determined to be 3.77 ± 0.002 Gy/min for EBT3, 4.04 ± 0.0022 Gy/min for EBT‐XD, and 4.25 ± 0.0017 Gy/min for HD‐V2. When the film material was changed to water, the dose rate was increased 14.3% for EBT3, 19.2% for EBT‐XD, and 15.0% for HD‐V2, with EBT3 showing the closest match to water‐equivalence. Calibration curves for each film model were generated by fitting a power function to their responses. Refinements to the dose range were necessary to achieve an uncertainty below the 5% threshold. Among the models, HD‐V2 required the most adjustments to its dose range and exhibited the highest levels of experimental, fit, and total uncertainties, along with the largest relative dose errors. Conclusions: This study investigated α‐particle dosimetry protocols for unlaminated EBT3, EBT‐XD, and HD‐V2 GafChromic film models using experimental irradiations and MC simulations. Although EBT3 and EBT‐XD demonstrate strong potential for α‐particle quality assurance in treatment planning, the HD‐V2 film model requires further investigation before it can be recommended for this application.

  • Open Access

    Establishing a standardized murine orthotopic intra-rectal model for the study of colorectal adenocarcinoma

    by Mélodie Cyr, Naim Chabaytah, Joud Babik, Behnaz Behmand, Guillaume St-Jean, Shirin A. Enger

    Original Article Establishing a standardized murine orthotopic intra-rectal model for the study of colorectal adenocarcinoma Mélodie Cyr, Naim Chabaytah, Joud Babik, Behnaz Behmand, Guillaume St-Jean, Shirin A. Enger


  • Open Access

    Investigation of the Dosimetry Characteristics of the GAFCHROMIC® EBT3 Film Response to Alpha Particle Irradiation

    by Mélodie Cyr, Victor D. Martinez, Slobodan Devic, Nada Tomic, David F. Lewis, Shirin A. Enger

    The purpose of this study was to investigate the dosimetric characteristics of the GAFCHROMIC® EBT3 film responding to alpha particle irradiation. Unlaminated GAFCHROMIC® EBT3 film pieces, were irradiated with a 30.055 kBq 241Am alpha source, at eight different dose levels, between 0 and 509 Gy. The irradiations were performed inside an enclosed box. Epson Expression 10000 XL scanner in transmission mode was used to digitize irradiated films 24 hours post-irradiations as 16-bit RGB images in tagged image file format (TIFF). Optical density (OD) values were obtained by following the OD theorem. Raw and normalized pixel values (PVnorm) from the red, green, and blue colour channels were sampled from a 3 × 3 mm2 region of interest. Calibration curves were created for both data sets (OD and PVnorm) and were fit accordingly. Monte Carlo simulations with the Geant4 toolkit were performed to establish a dose rate at the point within the sensitive layer of the film. An alpha dosimetry protocol for EBT3 films was obtained from the Monte Carlo calculated dose rate and dose calibration curves for alpha radiation were created. It is necessary to extend this study for different film types and compare to photon dosimetry calibration curves.