Eliane Aparecida Techi Castiquini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eliane Aparecida Techi Castiquini has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Luiz Fernando Manzoni Lourençone
Universidade de São Paulo, Brazil
5 shared publications - Cláudia Daniele Pelanda Zampronio
Universidade de São Paulo, Brasil
4 shared publications - Jerusa Roberta Massola de Oliveira
Universidade de São Paulo, Brasil
4 shared publications - Maria Fernanda Capoani Garcia Mondelli
Universidade de São Paulo, Brazil
4 shared publications - Rubens Vuono de Brito Neto
Universidade de São Paulo, Brasil
4 shared publications - Heloisa de Miranda Cantuaria Alves
Universidade de São Paulo, Brasil
2 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 37 (3) , e20240032
Efeito da prótese ativa de orelha média na percepção auditiva da fala em indivíduos com malformação de orelha
Objetivo Verificar os resultados da prótese ativa de orelha média na audibilidade e na percepção auditiva da fala em indivíduos com malformação de orelha externa e/ou média.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 37 (3) , e20240032
Open AccessEfeito da prótese ativa de orelha média na percepção auditiva da fala em indivíduos com malformação de orelha
Objetivo Verificar os resultados da prótese ativa de orelha média na audibilidade e na percepção auditiva da fala em indivíduos com malformação de orelha externa e/ou média.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 37 (3) , e20240032
Effect of active middle ear implant on auditory speech perception in individuals with ear malformation
Purpose To verify the results of active middle ear implant on audibility and auditory speech perception in individuals with external and/or middle ear malformations.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 37 (3) , e20240032
Open AccessEffect of active middle ear implant on auditory speech perception in individuals with ear malformation
Purpose To verify the results of active middle ear implant on audibility and auditory speech perception in individuals with external and/or middle ear malformations.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Audiology - Communication Research
- Vol. 29, e2905
Tools used in the subjective evaluation of bone anchored hearing aid users: scope review
Purpose to identify the questionnaires and scales used as subjective tools for the assessment process regarding the benefit and satisfaction of users of Bone-Anchored Hearing Aids to answer the following guiding question: Which questionnaires and scales are used in adults to evaluate the benefit and satisfaction of Bone-Anchored Hearing Aid users? Research strategy the search was carried out in the PubMed, SciELO, Scopus, Web of Science, Lilacs and Embase databases and, in gray literature, Google Academic and Brazilian Digital Library of Theses and Dissertations were used as information sources. The descriptors used were: bone-anchored prosthesis, hearing loss, mixed conductive-sensorineural, quality of life, patient satisfaction, surveys and questionnaires. Selection criteria studies that used questionnaires and scales to verify the benefit and satisfaction of users of Bone-Anchored Hearing Aid, published in Portuguese, English or Spanish, from 1999 to 2022, were included. Results 176 articles were identified. Of this total, 67 were included in the scoping review. The literature indicated that the most used tools in the process of assessing benefit and satisfaction in Bone-Anchored Hearing Aid users were the Glasgow Benefit Inventory questionnaires, the Abbreviated Profile of Hearing Aid Benefit , and the Speech, Spatial, and Quality of Hearing Scale. Conclusion There are several instruments to be used, such as the Glasgow Benefit Inventory and the Abbreviated Profile of Hearing Aid Benefit for benefits and the exclusive Audio Processor Satisfaction Questionnaire for the specific satisfaction of this population. As far as scales are concerned, The Speech, Spatial and Hearing Qualities Scale evaluates the benefit.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Audiology - Communication Research
- Vol. 29, e2905
Open AccessTools used in the subjective evaluation of bone anchored hearing aid users: scope review
Purpose to identify the questionnaires and scales used as subjective tools for the assessment process regarding the benefit and satisfaction of users of Bone-Anchored Hearing Aids to answer the following guiding question: Which questionnaires and scales are used in adults to evaluate the benefit and satisfaction of Bone-Anchored Hearing Aid users? Research strategy the search was carried out in the PubMed, SciELO, Scopus, Web of Science, Lilacs and Embase databases and, in gray literature, Google Academic and Brazilian Digital Library of Theses and Dissertations were used as information sources. The descriptors used were: bone-anchored prosthesis, hearing loss, mixed conductive-sensorineural, quality of life, patient satisfaction, surveys and questionnaires. Selection criteria studies that used questionnaires and scales to verify the benefit and satisfaction of users of Bone-Anchored Hearing Aid, published in Portuguese, English or Spanish, from 1999 to 2022, were included. Results 176 articles were identified. Of this total, 67 were included in the scoping review. The literature indicated that the most used tools in the process of assessing benefit and satisfaction in Bone-Anchored Hearing Aid users were the Glasgow Benefit Inventory questionnaires, the Abbreviated Profile of Hearing Aid Benefit , and the Speech, Spatial, and Quality of Hearing Scale. Conclusion There are several instruments to be used, such as the Glasgow Benefit Inventory and the Abbreviated Profile of Hearing Aid Benefit for benefits and the exclusive Audio Processor Satisfaction Questionnaire for the specific satisfaction of this population. As far as scales are concerned, The Speech, Spatial and Hearing Qualities Scale evaluates the benefit.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Audiology - Communication Research
- Vol. 29, e2905
Ferramentas utilizadas na avaliação subjetiva de usuários de prótese auditiva ancorada no osso: revisão de escopo
RESUMO Objetivo identificar os questionários e escalas utilizados na avaliação do benefício e da satisfação dos usuários de próteses auditivas ancoradas no osso, respondendo a questão norteadora: “Quais questionários e escalas são utilizados para avaliar o benefício e a satisfação dos usuários de prótese auditiva ancorada no osso?”. Estratégia de pesquisa busca realizada nas bases de dados Public Medicine Library, Scopus, Web of Science, LILACS e Embase. Na literatura cinzenta, utilizou-se a fonte de informação Google Acadêmico e a Biblioteca Digital Brasileira de Teses e dissertações, por meio dos descritores: prótese ancorada no osso (bone-anchored prosthesis), perda auditiva condutiva-neurossensorial mista (hearing loss, mixed conductive-sensorineural), qualidade de vida (quality of life), satisfação do paciente (patient satisfaction), inquéritos e questionários (surveys and questionnaires). Critérios de seleção incluídos estudos que utilizaram questionários e escalas para verificar o benefício e a satisfação dos usuários de prótese auditiva ancorada no osso, publicados em português, inglês ou espanhol, de 1999 até 2024. Resultados foram identificados 176 artigos e, destes, 67 foram incluídos na revisão de escopo. A literatura apontou que as ferramentas mais utilizadas foram os questionários Glasgow Benefit Inventory, o Abbreviated Profile of Hearing Aid Benefit e a escala Speech, Spatial, and Quality of Hearing Scale. Conclusão vários são os instrumentos utilizados na avaliação do benefício e da satisfação dos usuários de próteses auditivas ancoradas no osso, como o Glasgow Benefit Inventory e o Abbreviate Profile of Hearing Aid Benefit para benefício e o Audio Processor Satisfaction Questionnaire, exclusivo para satisfação específica dessa população. Quanto à escala tem-se a Speech, Spatial and Qualities of Hearing Scale para avaliar benefício.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Audiology - Communication Research
- Vol. 29, e2905
Open AccessFerramentas utilizadas na avaliação subjetiva de usuários de prótese auditiva ancorada no osso: revisão de escopo
RESUMO Objetivo identificar os questionários e escalas utilizados na avaliação do benefício e da satisfação dos usuários de próteses auditivas ancoradas no osso, respondendo a questão norteadora: “Quais questionários e escalas são utilizados para avaliar o benefício e a satisfação dos usuários de prótese auditiva ancorada no osso?”. Estratégia de pesquisa busca realizada nas bases de dados Public Medicine Library, Scopus, Web of Science, LILACS e Embase. Na literatura cinzenta, utilizou-se a fonte de informação Google Acadêmico e a Biblioteca Digital Brasileira de Teses e dissertações, por meio dos descritores: prótese ancorada no osso (bone-anchored prosthesis), perda auditiva condutiva-neurossensorial mista (hearing loss, mixed conductive-sensorineural), qualidade de vida (quality of life), satisfação do paciente (patient satisfaction), inquéritos e questionários (surveys and questionnaires). Critérios de seleção incluídos estudos que utilizaram questionários e escalas para verificar o benefício e a satisfação dos usuários de prótese auditiva ancorada no osso, publicados em português, inglês ou espanhol, de 1999 até 2024. Resultados foram identificados 176 artigos e, destes, 67 foram incluídos na revisão de escopo. A literatura apontou que as ferramentas mais utilizadas foram os questionários Glasgow Benefit Inventory, o Abbreviated Profile of Hearing Aid Benefit e a escala Speech, Spatial, and Quality of Hearing Scale. Conclusão vários são os instrumentos utilizados na avaliação do benefício e da satisfação dos usuários de próteses auditivas ancoradas no osso, como o Glasgow Benefit Inventory e o Abbreviate Profile of Hearing Aid Benefit para benefício e o Audio Processor Satisfaction Questionnaire, exclusivo para satisfação específica dessa população. Quanto à escala tem-se a Speech, Spatial and Qualities of Hearing Scale para avaliar benefício.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Audiology - Communication Research
- Vol. 29, e2821
Análise da restrição de participação e da audiometria de altas frequências em adultos e idosos com perda auditiva leve
RESUMO Objetivo comparar as respostas de adultos e idosos com perda auditiva de grau leve no inventário de restrição de participação e relacionar o grau de restrição com a perda auditiva em altas frequências, bem como avaliar se há diferença entre as respostas de homens e mulheres em relação à restrição de participação. Métodos a amostra foi composta por 38 adultos e idosos, com média de 67 anos de idade, de ambos os gêneros, matriculados em um serviço de saúde auditiva. Foi realizada audiometria de altas frequências e foram aplicados os questionários Hearing Handicap Inventory for Adults ou Hearing Handicap Inventory for Elderly. Os estudos estatísticos aplicados foram o teste de Mann-Whitney, análise de variância unidirecional e teste Qui-Quadrado. Resultados foram encontradas diferenças significativas entre os grupos de idosos e adultos em relação ao grau de restrição de participação, mas não foram encontradas correlações entre a audiometria de altas frequências e o grau de restrição de participação. Ainda, foi possível observar que as mulheres apresentaram maior grau de restrição de participação que os homens. Conclusão adultos apresentam maiores índices de percepção de restrição de participação quando comparados com idosos e há diferença entre a percepção do handicap conforme o gênero, porém, os resultados dos questionários não estão relacionados com a perda auditiva em altas frequências na população estudada.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Audiology - Communication Research
- Vol. 29, e2821
Open AccessAnálise da restrição de participação e da audiometria de altas frequências em adultos e idosos com perda auditiva leve
RESUMO Objetivo comparar as respostas de adultos e idosos com perda auditiva de grau leve no inventário de restrição de participação e relacionar o grau de restrição com a perda auditiva em altas frequências, bem como avaliar se há diferença entre as respostas de homens e mulheres em relação à restrição de participação. Métodos a amostra foi composta por 38 adultos e idosos, com média de 67 anos de idade, de ambos os gêneros, matriculados em um serviço de saúde auditiva. Foi realizada audiometria de altas frequências e foram aplicados os questionários Hearing Handicap Inventory for Adults ou Hearing Handicap Inventory for Elderly. Os estudos estatísticos aplicados foram o teste de Mann-Whitney, análise de variância unidirecional e teste Qui-Quadrado. Resultados foram encontradas diferenças significativas entre os grupos de idosos e adultos em relação ao grau de restrição de participação, mas não foram encontradas correlações entre a audiometria de altas frequências e o grau de restrição de participação. Ainda, foi possível observar que as mulheres apresentaram maior grau de restrição de participação que os homens. Conclusão adultos apresentam maiores índices de percepção de restrição de participação quando comparados com idosos e há diferença entre a percepção do handicap conforme o gênero, porém, os resultados dos questionários não estão relacionados com a perda auditiva em altas frequências na população estudada.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Audiology - Communication Research
- Vol. 29, e2821
Analysis of participation restriction and high-frequency audiometry in adults and elderly people with mild hearing loss
Purpose to compare the responses of adults and elderly people with mild hearing loss in the participation restriction inventory and relate the degree of restriction with hearing loss at high frequencies, as well as to evaluate whether there is a difference between the responses of men and women in relation to participation restrictions. Methods the sample of 38 participants was made up of adults and elderly people with an average of 67 years of age, of both sexes, enrolled in a hearing health service. High Frequency Audiometry was performed and the Hearing Handicap Inventory for Adults or Hearing Handicap Inventory for Elderly questionnaires were administered. The statistical study applied to the data was the Mann-Whitney test, oneway analysis of variance and Chi-Square. Results significant differences were found between the elderly and adult groups in relation to the degree of participation restriction, but no correlations were found between high frequency audiometry and the degree of participation restriction. It was also possible to observe that women have a greater degree of participation restriction than men. Conclusion adults have higher rates of perception of participation restrictions when compared to the elderly and there is a difference between the perception of handicap according to gender, but the results of the questionnaires are not related to hearing loss in high frequencies in this population.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Audiology - Communication Research
- Vol. 29, e2821
Open AccessAnalysis of participation restriction and high-frequency audiometry in adults and elderly people with mild hearing loss
Purpose to compare the responses of adults and elderly people with mild hearing loss in the participation restriction inventory and relate the degree of restriction with hearing loss at high frequencies, as well as to evaluate whether there is a difference between the responses of men and women in relation to participation restrictions. Methods the sample of 38 participants was made up of adults and elderly people with an average of 67 years of age, of both sexes, enrolled in a hearing health service. High Frequency Audiometry was performed and the Hearing Handicap Inventory for Adults or Hearing Handicap Inventory for Elderly questionnaires were administered. The statistical study applied to the data was the Mann-Whitney test, oneway analysis of variance and Chi-Square. Results significant differences were found between the elderly and adult groups in relation to the degree of participation restriction, but no correlations were found between high frequency audiometry and the degree of participation restriction. It was also possible to observe that women have a greater degree of participation restriction than men. Conclusion adults have higher rates of perception of participation restrictions when compared to the elderly and there is a difference between the perception of handicap according to gender, but the results of the questionnaires are not related to hearing loss in high frequencies in this population.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 36 (1) , e20220271
Hearing rehabilitation with Baha® transcutaneous and percutaneous systems
Purpose Longitudinally verify the influence of auditory tonal thresholds obtained with transcutaneous and percutaneous bone-anchored hearing aids on speech perception in individuals with external and/or middle ear malformation and chronic otitis media. Methods Observational, retrospective, longitudinal follow-up study of 30 unilateral users of the transcutaneous and percutaneous Baha® system for the collection of secondary data on pure tone thresholds obtained through free field audiometry and sentence recognition threshold in silence and noise in conditions: without the prosthesis; at the time of activation; in the first month of use (post 1); and in the third month (post 2). Results There was a significant difference between pure tone thresholds obtained at frequencies of 3 and 4kHz with better results for the percutaneous technique at all evaluation moments. For both systems, better performance was observed in sentence recognition in silence and in noise, with a significant difference in activation (p<0.001), but it remained stable during the other evaluation moments. The percutaneous system showed better benefit in recognizing sentences in noise only on activation (p=0.036), when compared to the transcutaneous system. Conclusion The percutaneous system provided better audibility for high frequencies; however, such audibility did not influence sentence recognition in the silent situation for both systems. For the noise situation, better responses were observed in the percutaneous system, however, the difference was not maintained over time.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 36 (1) , e20220271
Open AccessHearing rehabilitation with Baha® transcutaneous and percutaneous systems
Purpose Longitudinally verify the influence of auditory tonal thresholds obtained with transcutaneous and percutaneous bone-anchored hearing aids on speech perception in individuals with external and/or middle ear malformation and chronic otitis media. Methods Observational, retrospective, longitudinal follow-up study of 30 unilateral users of the transcutaneous and percutaneous Baha® system for the collection of secondary data on pure tone thresholds obtained through free field audiometry and sentence recognition threshold in silence and noise in conditions: without the prosthesis; at the time of activation; in the first month of use (post 1); and in the third month (post 2). Results There was a significant difference between pure tone thresholds obtained at frequencies of 3 and 4kHz with better results for the percutaneous technique at all evaluation moments. For both systems, better performance was observed in sentence recognition in silence and in noise, with a significant difference in activation (p<0.001), but it remained stable during the other evaluation moments. The percutaneous system showed better benefit in recognizing sentences in noise only on activation (p=0.036), when compared to the transcutaneous system. Conclusion The percutaneous system provided better audibility for high frequencies; however, such audibility did not influence sentence recognition in the silent situation for both systems. For the noise situation, better responses were observed in the percutaneous system, however, the difference was not maintained over time.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 36 (1) , e20220271
Reabilitação auditiva com sistemas Baha® transcutâneo e percutâneo
RESUMO Objetivo Verificar longitudinalmente a influência dos limiares tonais auditivos obtidos com as próteses auditivas ancoradas no osso transcutâneas e percutâneas na percepção da fala em indivíduos com malformação de orelha externa e/ou média e Otite Média Crônica. Método Estudo observacional, retrospectivo, de seguimento longitudinal de 30 indivíduos usuários unilaterais de sistema Baha® transcutâneo e percutâneo, para coleta de dados secundários dos limiares tonais obtidos por meio da audiometria em campo livre e do limiar de reconhecimento de sentenças no silêncio e no ruído nas condições: sem a prótese; no momento de ativação; no primeiro mês de uso (pós 1); e no terceiro mês (pós 2). Resultados Houve diferença significante entre os limiares tonais obtidos nas frequências de 3 e 4kHz, com melhores resultados para o percutâneo em todos os momentos de avaliação. Para os dois sistemas, observou-se melhor desempenho no reconhecimento de sentenças no silêncio e ruído, com diferença significante na ativação (p<0,001), porém manteve-se estável nos demais momentos de avaliação. O sistema percutâneo mostrou melhor benefício no reconhecimento de sentenças no ruído apenas na ativação (p=0,036), quando comparado ao transcutâneo. Conclusão O sistema percutâneo possibilitou melhor audibilidade para as frequências altas; contudo, tal audibilidade não influenciou no reconhecimento de sentenças na situação de silêncio para ambos os sistemas. Para a situação de ruído, melhores respostas foram observadas no sistema percutâneo; porém, a diferença não se manteve no decorrer do tempo.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 36 (1) , e20220271
Open AccessReabilitação auditiva com sistemas Baha® transcutâneo e percutâneo
RESUMO Objetivo Verificar longitudinalmente a influência dos limiares tonais auditivos obtidos com as próteses auditivas ancoradas no osso transcutâneas e percutâneas na percepção da fala em indivíduos com malformação de orelha externa e/ou média e Otite Média Crônica. Método Estudo observacional, retrospectivo, de seguimento longitudinal de 30 indivíduos usuários unilaterais de sistema Baha® transcutâneo e percutâneo, para coleta de dados secundários dos limiares tonais obtidos por meio da audiometria em campo livre e do limiar de reconhecimento de sentenças no silêncio e no ruído nas condições: sem a prótese; no momento de ativação; no primeiro mês de uso (pós 1); e no terceiro mês (pós 2). Resultados Houve diferença significante entre os limiares tonais obtidos nas frequências de 3 e 4kHz, com melhores resultados para o percutâneo em todos os momentos de avaliação. Para os dois sistemas, observou-se melhor desempenho no reconhecimento de sentenças no silêncio e ruído, com diferença significante na ativação (p<0,001), porém manteve-se estável nos demais momentos de avaliação. O sistema percutâneo mostrou melhor benefício no reconhecimento de sentenças no ruído apenas na ativação (p=0,036), quando comparado ao transcutâneo. Conclusão O sistema percutâneo possibilitou melhor audibilidade para as frequências altas; contudo, tal audibilidade não influenciou no reconhecimento de sentenças na situação de silêncio para ambos os sistemas. Para a situação de ruído, melhores respostas foram observadas no sistema percutâneo; porém, a diferença não se manteve no decorrer do tempo.
- Open Access
- 2 November 2023
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 44 (10) , 1045-1051
High-Frequency Gain and Maximum Output Effects on Speech Recognition in Bone-Conduction Hearing Devices: Blinded Study
Introduction: Bone-conduction hearing device (BCHD) uses natural sound transmission through bone and soft tissue, directly to the cochlea, via an external processor that captures and processes sound, which is converted into mechanical vibrations. Key parameters, as maximum power output (MPO) and broader frequency range (FR), must be considered when indicating a BCHD because they can be decisive for speech recognition, especially under listening challenge conditions. Objectives: Compare hearing performance and speech recognition in noise of two sound processors (SPs), with different features of MPO and FR, among BCHD users. Materials and Methods: This single-blinded, comparative, observational study evaluated 21 individuals Baha 4 system users with conductive or mixed hearing impairment. The free-field audiometry and speech recognition results were blindly collected under the following conditions: unaided, with Baha 5, and with Baha 6 Max SP. Results: In free-field audiometry, significant differences were observed between the SP at 0.25, 3, 4, 6, and 8 kHz, with Baha 6 Max outperforming Baha 5. The Baha 6 Max provided significantly better speech recognition than Baha 5 under all the speech in noise conditions evaluated. Separating the transcutaneous from the percutaneous users, Baha 6 Max Attract SP provided the best results and significantly lowered the free-field thresholds than Baha 5 Attract. The Baha 6 Max also significantly improved speech recognition in noise, among both Attract and Connect users. Conclusion: The present study revealed that the greater MPO and broader FR of the Baha 6 Max device helped increase high-frequency gain and improved speech recognition in BCHD-experimented users.
- 2 November 2023
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 44 (10) , 1045-1051
Open AccessHigh-Frequency Gain and Maximum Output Effects on Speech Recognition in Bone-Conduction Hearing Devices: Blinded Study
Introduction: Bone-conduction hearing device (BCHD) uses natural sound transmission through bone and soft tissue, directly to the cochlea, via an external processor that captures and processes sound, which is converted into mechanical vibrations. Key parameters, as maximum power output (MPO) and broader frequency range (FR), must be considered when indicating a BCHD because they can be decisive for speech recognition, especially under listening challenge conditions. Objectives: Compare hearing performance and speech recognition in noise of two sound processors (SPs), with different features of MPO and FR, among BCHD users. Materials and Methods: This single-blinded, comparative, observational study evaluated 21 individuals Baha 4 system users with conductive or mixed hearing impairment. The free-field audiometry and speech recognition results were blindly collected under the following conditions: unaided, with Baha 5, and with Baha 6 Max SP. Results: In free-field audiometry, significant differences were observed between the SP at 0.25, 3, 4, 6, and 8 kHz, with Baha 6 Max outperforming Baha 5. The Baha 6 Max provided significantly better speech recognition than Baha 5 under all the speech in noise conditions evaluated. Separating the transcutaneous from the percutaneous users, Baha 6 Max Attract SP provided the best results and significantly lowered the free-field thresholds than Baha 5 Attract. The Baha 6 Max also significantly improved speech recognition in noise, among both Attract and Connect users. Conclusion: The present study revealed that the greater MPO and broader FR of the Baha 6 Max device helped increase high-frequency gain and improved speech recognition in BCHD-experimented users.