Cong Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Cong Li has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Kaishun Wu
The Hong Kong University of Science and Technology (Guangzhou), Guangzhou, China
4 shared publications - Lin Chen
HKUST (GZ), Guangzhou, China
2 shared publications - Qian Zhang
Hong Kong University of Science and Technology, Hong Kong, Hong Kong
2 shared publications - Yandao Huang
Hong Kong University of Science and Technology
2 shared publications - Chang Huang
The Hong Kong University of Science and Technology (Guangzhou), Guangzhou, China
1 shared publication - Chenggao Li
Hong Kong University of Science and Technology
1 shared publication
Latest Publications
- 3 November 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (45) , 62369-62378
Body-Coupled Organic Electrochemical Transistors for Imperceptible Skin Bioelectronics
The efficient ion-to-electron transduction mechanism makes organic electrochemical transistors (OECTs) stand out for physiological sensing. Usually, OECT operations require saline solutions or hydrogels to function as the electrolytes; however, the wet electrolytes may compromise wear comfort and device stability for human-integrated applications. In this work, we propose a body-coupled OECT (b-OECT) device mechanism, where the skin and subcutaneous tissues act as natural electrolyte for the device operation. In the b-OECT, the organic semiconducting channel forms intimate and substrate-free contact with skins, enabling biofluid-derived ionic pathways to directly mediate gate–channel coupling and electrochemical modulation. The devices exhibit body-coupled transistor characteristics, skin-coupled operation, and ion-mediated neuromorphic-like conductance modulation. Without needing external supplied electrolytes, the b-OECT offers breathable and imperceptible body integration, where biological tissue directly participates in electrochemical signal transduction, opening potentials for skin-integrated bioelectronics and body-coupled neuromorphic biointerfaces.
- 3 November 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (45) , 62369-62378
Body-Coupled Organic Electrochemical Transistors for Imperceptible Skin Bioelectronics
The efficient ion-to-electron transduction mechanism makes organic electrochemical transistors (OECTs) stand out for physiological sensing. Usually, OECT operations require saline solutions or hydrogels to function as the electrolytes; however, the wet electrolytes may compromise wear comfort and device stability for human-integrated applications. In this work, we propose a body-coupled OECT (b-OECT) device mechanism, where the skin and subcutaneous tissues act as natural electrolyte for the device operation. In the b-OECT, the organic semiconducting channel forms intimate and substrate-free contact with skins, enabling biofluid-derived ionic pathways to directly mediate gate–channel coupling and electrochemical modulation. The devices exhibit body-coupled transistor characteristics, skin-coupled operation, and ion-mediated neuromorphic-like conductance modulation. Without needing external supplied electrolytes, the b-OECT offers breathable and imperceptible body integration, where biological tissue directly participates in electrochemical signal transduction, opening potentials for skin-integrated bioelectronics and body-coupled neuromorphic biointerfaces.
- Open Access
- 16 March 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (1) , 1-25
Sensing Life in Stillness: Unified Dynamic and Static Human Mesh Reconstruction with mmWave Radar
Continuous rehabilitation monitoring outside clinics is critical for long-term recovery, yet existing modalities fall short. Vision- and wearable-based systems raise privacy and compliance concerns, while RF-based sensing, despite contactless, is fundamentally motion-dependent —blind to the stillness that characterizes balance, endurance, and postural control. We observe that conventional static clutter removal not only suppresses environmental reflections but also erases the body's involuntary micro-motions, such as breathing, heartbeat, and subtle sway. Our key insight is that these micro-motions are not noise but information, encoding physiological vitality even in apparent stillness. Realizing this shift—from detecting motion to perceiving life within stillness—introduces two fundamental challenges: (C1) the echoes of these micro-motions are orders of magnitude weaker than static clutter, spectrally overlap within the near-zero Doppler region and spatially co-located with dominant reflections; and (C2) mmWave reflections are inherently sparse and geometry-agnostic, lacking the structural priors required to recover body's shape and pose across users and environments. To address these, we design mmRehab, a transformative mmWave sensing system for rehabilitation, extending radar perception beyond motion to enable physiological interpretation even when users remain still. Within mmRehab, Micro-motion Feature Extraction addresses C1 through beamforming-based spatial isolation and micro-Doppler temporal discrimination, amplifying respiration- and posture-related cues; Geometry-aware Knowledge Transfer addresses C2 via depth-guided distillation, transferring structural priors from vision to radar representations for robust generalization. Extensive experiments on both dynamic and static rehabilitation tasks show that mmRehab reduces 3D reconstruction errors by over 24% and generalizes robustly to unseen users, distances, and orientations—demonstrating the feasibility of unified radar perception for motion and micro-motion rehabilitation monitoring.
- 16 March 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (1) , 1-25
Open AccessSensing Life in Stillness: Unified Dynamic and Static Human Mesh Reconstruction with mmWave Radar
Continuous rehabilitation monitoring outside clinics is critical for long-term recovery, yet existing modalities fall short. Vision- and wearable-based systems raise privacy and compliance concerns, while RF-based sensing, despite contactless, is fundamentally motion-dependent —blind to the stillness that characterizes balance, endurance, and postural control. We observe that conventional static clutter removal not only suppresses environmental reflections but also erases the body's involuntary micro-motions, such as breathing, heartbeat, and subtle sway. Our key insight is that these micro-motions are not noise but information, encoding physiological vitality even in apparent stillness. Realizing this shift—from detecting motion to perceiving life within stillness—introduces two fundamental challenges: (C1) the echoes of these micro-motions are orders of magnitude weaker than static clutter, spectrally overlap within the near-zero Doppler region and spatially co-located with dominant reflections; and (C2) mmWave reflections are inherently sparse and geometry-agnostic, lacking the structural priors required to recover body's shape and pose across users and environments. To address these, we design mmRehab, a transformative mmWave sensing system for rehabilitation, extending radar perception beyond motion to enable physiological interpretation even when users remain still. Within mmRehab, Micro-motion Feature Extraction addresses C1 through beamforming-based spatial isolation and micro-Doppler temporal discrimination, amplifying respiration- and posture-related cues; Geometry-aware Knowledge Transfer addresses C2 via depth-guided distillation, transferring structural priors from vision to radar representations for robust generalization. Extensive experiments on both dynamic and static rehabilitation tasks show that mmRehab reduces 3D reconstruction errors by over 24% and generalizes robustly to unseen users, distances, and orientations—demonstrating the feasibility of unified radar perception for motion and micro-motion rehabilitation monitoring.
- Open Access
- 3 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 1302-1304
Poster: Contactless Cardiovascular Hemodynamics Inference and Hypertension Detection via Ballistocardiogram
- 3 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 1302-1304
Open AccessPoster: Contactless Cardiovascular Hemodynamics Inference and Hypertension Detection via Ballistocardiogram
- Open Access
- 27 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 4962-4971
DACA-Net: A Degradation-Aware Conditional Diffusion Network for Underwater Image Enhancement
- 27 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 4962-4971
Open AccessDACA-Net: A Degradation-Aware Conditional Diffusion Network for Underwater Image Enhancement
- 9 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 10 (23) , 20789-20802
MM-Tap: Adaptive and Scalable Tap Localization on Ubiquitous Surfaces With mm-Level Accuracy
Transforming physical surfaces into virtual interfaces can extend the interaction capability of many exciting metaverse applications in the future. Recent advances in vibration-based tap sensing show promise for this vision using passive vibration signals. However, current approaches based on Time-Difference-of-Arrival (TDoA) triangulation suffer the impact of fluctuant wave velocity due to the dispersive and heterogeneous nature of solid mediums, failing to meet the performance requirement for practical use. In this paper, we present MM-Tap, a vibration-based tap localization system that can transform ubiquitous surfaces into virtual touch screens with low overhead. A novel localization scheme is proposed based on the finding of spatio-temporal mapping between tap locations and TDoA values, which pushes the accuracy limits of vibration-based tap sensing from unstable cm-level to mm-level. We investigate the geometry of the sensor layout and design a model-based method to synthesize tap data, which enables MM-Tap to adapt to various surface materials and respond to arbitrary sensing scales after a few seconds of calibration. We combine MM-Tap with a COTS projector and facilitate a digitally augmented surface where users can play video games with low latency.
- 9 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 10 (23) , 20789-20802
MM-Tap: Adaptive and Scalable Tap Localization on Ubiquitous Surfaces With mm-Level Accuracy
Transforming physical surfaces into virtual interfaces can extend the interaction capability of many exciting metaverse applications in the future. Recent advances in vibration-based tap sensing show promise for this vision using passive vibration signals. However, current approaches based on Time-Difference-of-Arrival (TDoA) triangulation suffer the impact of fluctuant wave velocity due to the dispersive and heterogeneous nature of solid mediums, failing to meet the performance requirement for practical use. In this paper, we present MM-Tap, a vibration-based tap localization system that can transform ubiquitous surfaces into virtual touch screens with low overhead. A novel localization scheme is proposed based on the finding of spatio-temporal mapping between tap locations and TDoA values, which pushes the accuracy limits of vibration-based tap sensing from unstable cm-level to mm-level. We investigate the geometry of the sensor layout and design a model-based method to synthesize tap data, which enables MM-Tap to adapt to various surface materials and respond to arbitrary sensing scales after a few seconds of calibration. We combine MM-Tap with a COTS projector and facilitate a digitally augmented surface where users can play video games with low latency.