Daniele Fortunato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniele Fortunato has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Marco Knaflitz
Department of Electronics and Telecommunications and the PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
4 shared publications - Gabriella Balestra
Department of Electronics and Telecommunications – Politecnico di Torino, Italy
2 shared publications - Gregorio Dotti
Dipartimento di Elettronica e Telecomunicazioni, Politecnico di Torino, Corso Castelfidardo 39, Torino, 10129, ITALY
2 shared publications - Marco Ghislieri
Politecnico di Torino
2 shared publications - Samanta Rosati
Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy
2 shared publications - Valentina Agostini
Politecnico di Torino
2 shared publications
Latest Publications
- Open Access
- 4 May 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 186, 112711
Vertical displacement of the approximated body center of mass during typical daily activities: A transition-based complementary filter method using barometric and inertial data
- 4 May 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 186, 112711
Open AccessVertical displacement of the approximated body center of mass during typical daily activities: A transition-based complementary filter method using barometric and inertial data
- Open Access
A Statistical Approach for Functional Reach-to-Grasp Segmentation Using a Single Inertial Measurement Unit
The aim of this contribution is to present a segmentation method for the identification of voluntary movements from inertial data acquired through a single inertial measurement unit placed on the subject’s wrist. Inertial data were recorded from 25 healthy subjects while performing 75 consecutive reach-to-grasp movements. The approach herein presented, called DynAMoS, is based on an adaptive thresholding step on the angular velocity norm, followed by a statistics-based post-processing on the movement duration distribution. Post-processing aims at reducing the number of erroneous transitions in the movement segmentation. We assessed the segmentation quality of this method using a stereophotogrammetric system as the gold standard. Two popular methods already presented in the literature were compared to DynAMoS in terms of the number of movements identified, onset and offset mean absolute errors, and movement duration. Moreover, we analyzed the sub-phase durations of the drinking movement to further characterize the task. The results show that the proposed method performs significantly better than the two state-of-the-art approaches (i.e., percentage of erroneous movements = 3%; onset and offset mean absolute error < 0.08 s), suggesting that DynAMoS could make more effective home monitoring applications for assessing the motion improvements of patients following domicile rehabilitation protocols.
Open AccessA Statistical Approach for Functional Reach-to-Grasp Segmentation Using a Single Inertial Measurement Unit
The aim of this contribution is to present a segmentation method for the identification of voluntary movements from inertial data acquired through a single inertial measurement unit placed on the subject’s wrist. Inertial data were recorded from 25 healthy subjects while performing 75 consecutive reach-to-grasp movements. The approach herein presented, called DynAMoS, is based on an adaptive thresholding step on the angular velocity norm, followed by a statistics-based post-processing on the movement duration distribution. Post-processing aims at reducing the number of erroneous transitions in the movement segmentation. We assessed the segmentation quality of this method using a stereophotogrammetric system as the gold standard. Two popular methods already presented in the literature were compared to DynAMoS in terms of the number of movements identified, onset and offset mean absolute errors, and movement duration. Moreover, we analyzed the sub-phase durations of the drinking movement to further characterize the task. The results show that the proposed method performs significantly better than the two state-of-the-art approaches (i.e., percentage of erroneous movements = 3%; onset and offset mean absolute error < 0.08 s), suggesting that DynAMoS could make more effective home monitoring applications for assessing the motion improvements of patients following domicile rehabilitation protocols.
- Open Access
- 23 May 2024
- Published by IOS Press
- Vol. 314, 155-159
Personalized Detection of Motion Artifacts for Telemonitoring Applications
Among its main benefits, telemonitoring enables personalized management of chronic diseases by means of biomarkers extracted from signals. In these applications, a thorough quality assessment is required to ensure the reliability of the monitored parameters. Motion artifacts are a common problem in recordings with wearable devices. In this work, we propose a fully automated and personalized method to detect motion artifacts in multimodal recordings devoted to the monitoring of the Cardiac Time Intervals (CTIs). The detection of motion artifacts was carried out by using template matching with a personalized template. The method yielded a balanced accuracy of 86%. Moreover, it proved effective to decrease the variability of the estimated CTIs by at least 17%. Our preliminary results show that personalized detection of motion artifacts improves the robustness of the assessment CTIs and opens to the use in wearable systems.
- 23 May 2024
- Published by IOS Press
- Vol. 314, 155-159
Open AccessPersonalized Detection of Motion Artifacts for Telemonitoring Applications
Among its main benefits, telemonitoring enables personalized management of chronic diseases by means of biomarkers extracted from signals. In these applications, a thorough quality assessment is required to ensure the reliability of the monitored parameters. Motion artifacts are a common problem in recordings with wearable devices. In this work, we propose a fully automated and personalized method to detect motion artifacts in multimodal recordings devoted to the monitoring of the Cardiac Time Intervals (CTIs). The detection of motion artifacts was carried out by using template matching with a personalized template. The method yielded a balanced accuracy of 86%. Moreover, it proved effective to decrease the variability of the estimated CTIs by at least 17%. Our preliminary results show that personalized detection of motion artifacts improves the robustness of the assessment CTIs and opens to the use in wearable systems.
- Open Access
Evaluation of Muscle Function by Means of a Muscle-Specific and a Global Index
Gait analysis applications in clinics are still uncommon, for three main reasons: (1) the considerable time needed to prepare the subject for the examination; (2) the lack of user-independent tools; (3) the large variability of muscle activation patterns observed in healthy and pathological subjects. Numerical indices quantifying the muscle coordination of a subject could enable clinicians to identify patterns that deviate from those of a reference population and to follow the progress of the subject after surgery or completing a rehabilitation program. In this work, we present two user-independent indices. First, a muscle-specific index (MFI) that quantifies the similarity of the activation pattern of a muscle of a specific subject with that of a reference population. Second, a global index (GFI) that provides a score of the overall activation of a muscle set. These two indices were tested on two groups of healthy and pathological children with encouraging results. Hence, the two indices will allow clinicians to assess the muscle activation, identifying muscles showing an abnormal activation pattern, and associate a functional score to every single muscle as well as to the entire muscle set. These opportunities could contribute to facilitating the diffusion of surface EMG analysis in clinics.
Open AccessEvaluation of Muscle Function by Means of a Muscle-Specific and a Global Index
Gait analysis applications in clinics are still uncommon, for three main reasons: (1) the considerable time needed to prepare the subject for the examination; (2) the lack of user-independent tools; (3) the large variability of muscle activation patterns observed in healthy and pathological subjects. Numerical indices quantifying the muscle coordination of a subject could enable clinicians to identify patterns that deviate from those of a reference population and to follow the progress of the subject after surgery or completing a rehabilitation program. In this work, we present two user-independent indices. First, a muscle-specific index (MFI) that quantifies the similarity of the activation pattern of a muscle of a specific subject with that of a reference population. Second, a global index (GFI) that provides a score of the overall activation of a muscle set. These two indices were tested on two groups of healthy and pathological children with encouraging results. Hence, the two indices will allow clinicians to assess the muscle activation, identifying muscles showing an abnormal activation pattern, and associate a functional score to every single muscle as well as to the entire muscle set. These opportunities could contribute to facilitating the diffusion of surface EMG analysis in clinics.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 197-200
A wearable device to assess postural sway
The maintenance of balance in upright stance is traditionally evaluated using heavy and expensive force platforms. The aim of this work is to prove the usefulness of a low-cost wearable sensor (an actigraph) to assess postural sway. We compared the performance of the device to a gold standard force platform. We analyzed measurements of postural sway in four conditions differently challenging the subject: with eyes open or closed, while keeping a small or large base of support. We estimated the main postural parameters (ellipse area, mediolateral and antero-posterior root-mean square, eccentricity, sway path length) considering: 1) acceleration data recorded by the actigraph, and 2) traditional COP data obtained from the force platform. We found that it is possible to clearly distinguish the differences among the postural parameters, obtained in the various balance conditions, also using acceleration data. Our results show that the wearable device allows for obtaining information similar to those achievable by the force platform. This support the use of wearable devices to assess postural balance, in a handy and cheap manner.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 197-200
A wearable device to assess postural sway
The maintenance of balance in upright stance is traditionally evaluated using heavy and expensive force platforms. The aim of this work is to prove the usefulness of a low-cost wearable sensor (an actigraph) to assess postural sway. We compared the performance of the device to a gold standard force platform. We analyzed measurements of postural sway in four conditions differently challenging the subject: with eyes open or closed, while keeping a small or large base of support. We estimated the main postural parameters (ellipse area, mediolateral and antero-posterior root-mean square, eccentricity, sway path length) considering: 1) acceleration data recorded by the actigraph, and 2) traditional COP data obtained from the force platform. We found that it is possible to clearly distinguish the differences among the postural parameters, obtained in the various balance conditions, also using acceleration data. Our results show that the wearable device allows for obtaining information similar to those achievable by the force platform. This support the use of wearable devices to assess postural balance, in a handy and cheap manner.