JSJacob Schultheiss

Jacob Schultheiss

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jacob Schultheiss has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Barbara Illing

    Department of Medical Materials Science & Technology, Institute of Biomedical Engineering, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany

    4 shared publications
  • Evi Kimmerle-Mueller

    Department of Medical Materials Science & Technology, Institute of Biomedical Engineering, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany

    4 shared publications
  • Frank Rupp

    Department of Medical Materials Science & Technology, Institute of Biomedical Engineering, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany

    4 shared publications
  • Stefanie Krajewski

    Department of Medical Materials Science & Technology, Institute of Biomedical Engineering, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany

    4 shared publications
  • Leila Mohammadnejad

    Department of Medical Materials Science & Technology, Institute of Biomedical Engineering, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany

    3 shared publications
  • Antonia Theurer

    Department Medical Materials Science & Technology, Institute for Biomedical Engineering, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany

    2 shared publications

Latest Publications

  • Open Access

    Cytocompatibility Assessment of L-PBF-Manufactured Zinc–Silver–Copper Alloys for Customized Biodegradable Medical Implants

    by Barbara Illing, Jacob Schultheiss, Lukas Schumacher, Evi Kimmerle-Mueller, Ariadne Roehler, Alexander Heiss, Ulrich E. Klotz, Victor O. Okafor, Stefanie Krajewski, Frank Rupp

    Biodegradable zinc (Zn) has attracted increasing interest as a material for temporary implants, primarily due to its moderate degradation kinetics. In recent years, additive manufacturing of Zn alloys using the laser powder bed fusion method (L-PBF) has shown promising results. Compared to as-cast Zn alloys, it offers preferable customized solutions for patient-specific temporary biomedical implants. Due to the novelty of these printed degradable biomaterials and due to reported cytotoxic effects of Zn alloys, this study investigates additively manufactured ZnAgCu, ZnAgCuMn, and ZnAgCuTi alloys, both in as-printed and post-processed conditions, with a focus on L929 and SAOS-2 biocompatibility. In this work, we demonstrate that the increased porosity and therefore larger surface areas compared to polished Zn-alloy samples affect their biocompatibility. Minimal to no cell proliferation was observed on and near the Zn-alloy test plates after 24 h. Undiluted extracts from as-cast Zn and L-PBF-manufactured plates were initially cytotoxic to SAOS-2 cells. However, as passivation proceeded, cytocompatibility was significantly increased from day 3 onward. Zn2+ ion release peaked at 24 h and declined significantly from day 2 to day 10. Compared to the other Zn alloys, ZnAgCuMn exhibited the lowest cytocompatibility. Most intriguingly, 3-month surfaces exhibited reduced cytocompatibility to osteoblasts compared to freshly polished samples. The observed in vitro cytotoxicity motivates further investigation of as-printed and post-processed L-PBF-manufactured Zn alloys, aiming to develop novel surface modification strategies to mitigate the initial ion burst responsible for reduced cytocompatibility and to adjust and tailor the overall degradation kinetics to physiologically tolerable levels tailored to the intended clinical application.


  • Open Access

    Superhydrophilic Hierarchical Anatase Coating on Sandblasted, Acid-Etched Titanium: In Vitro Apatite Formation and Osteoblast Responses and the Role of Polar Surface Free Energy

    by Leila Mohammadnejad, Wafa Zafira, Jacob Schultheiss, Lenny Crocoll, Evi Kimmerle-Mueller, Barbara Illing, Katharina Keppeler, Markus Turad, Annika Hechler, Christiane von Ohle, et al.

    Physicochemical modification of titanium implants aims to enhance early osseointegration by improving bioactivity. This study deposited and evaluated an anatase TiO2 film on clinically relevant sandblasted, acid-etched titanium (Ti-SLA) to enhance in vitro bioactivity and osteogenic responses. An ~8 µm TiO2-anatase coating was deposited on Ti-SLA by reactive pulsed DC magnetron sputtering. Surface characterization included FE-SEM, helium ion microscopy, and XRD. Wettability and surface free energy (SFE) were evaluated by contact angle analysis. In vitro bioactivity was assessed by hydroxyapatite (HA) formation in twofold-concentrated simulated body fluid (2× SBF). Osteoblast responses were evaluated through cell adhesion, viability, alkaline phosphatase activity, gene expression, and mineralization. The coating produced hierarchical multi-globular microstructures decorated with faceted anatase nanocrystals. Ti-SLA’s initial hydrophobicity converted to a superhydrophilic, high-energy surface with increased polar SFE. Homogeneous HA crystallites deposited exclusively on SLA-anatase in 2× SBF. SAOS-2 cells showed enhanced metabolic activity, ALP activity, osteogenic gene upregulation, and improved mineralized matrix, while primary human osteoblasts exhibited increased metabolic activity and calcium deposition. The anatase coating produced a superhydrophilic, high-energy micro-nano surface that accelerates HA formation and enhances osteoblast function in vitro, warranting in vivo validation for early osseointegration.


  • Open Access

    Surface-Mediated Modulation of Different Biological Responses on Anatase-Coated Titanium

    by Leila Mohammadnejad, Antonia Theurer, Julia Alber, Barbara Illing, Evi Kimmerle-Mueller, Jacob Schultheiss, Stefanie Krajewski, Frank Rupp

    Various surface modification strategies are being developed to endow dental titanium implant surfaces with micro- and nano-structures to improve their biocompatibility, and first of all their osseointegration. These modifications have the potential to address clinical concerns by stimulating different biological processes. This study aims to evaluate the biological responses of ananatase-modified blasted/etched titanium (SLA-anatase) surfaces compared to blasted/acid etched (SLA) and machined titanium surfaces. Using unipolar pulsed direct current (DC) sputtering, a nanocrystalline anatase layer was fabricated. In vitro experiments have shown that SLA-anatase discs can effectively promote osteoblast adhesion and proliferation, which are regarded as important features of a successful dental implant with bone contact. Furthermore, anatase surface modification has been shown to partially enhance osteoblast mineralization in vitro, while not significantly affecting bacterial colonization. Consequently, the recently created anatase coating holds significant potential as a promising candidate for future advancements in dental implant surface modification for improving the initial stages of osseointegration.


  • Open Access

    Biological Performance of Titanium Surfaces with Different Hydrophilic and Nanotopographical Features

    by Barbara Illing, Leila Mohammadnejad, Antonia Theurer, Jacob Schultheiss, Evi Kimmerle-Mueller, Frank Rupp, Stefanie Krajewski

    The micro- and nanostructures, chemical composition, and wettability of titanium surfaces are essential for dental implants’ osseointegration. Combining hydrophilicity and nanostructure has been shown to improve the cell response and to shorten the healing time. This study aimed to investigate the biological response to different wettability levels and nanotopographical modifications in aged and non-aged titanium surfaces. By plasma etching titanium surfaces with the fluorine gas 2,3,3,3-tetrafluoropropene (R1234yF), additional nanostructures were created on the sample surfaces. Furthermore, this treatment resulted in sustained superhydrophilicity and fluoride accumulation. We examined the effect of various nanostructuring processes and aging using scanning electron microscopy, roughness analyses, and wettability measurement. In addition, all the surface modifications were tested for their effects on fibroblast adhesion, proliferation, and viability as well as osteoblast differentiation. Our study indicates that the plasma etching, with 2,3,3,3-tetrafluoropropene, of the machined and SLA surface neither favored nor had an adverse effect on the biological response of the SAOS-2 osteoblast cell line. Although the fluorine-plasma-etched surfaces demonstrated improved fibroblast cell viability, they did not lead to improved early osseointegration. It is still unclear which surface properties mainly influence fibroblast and osteoblast adhesion. Further physiochemical aspects, such as electrostatic interaction and surface tension, are crucial to be analyzed along with wettability and roughness.