JMJagdeep S. Mohal

Jagdeep S. Mohal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jagdeep S. Mohal has a total of 94 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • International Experience With Implantable Cardioverter Defibrillators for the Prevention of Sudden Death in High-Risk Patients With Hypertrophic Cardiomyopathy

    by Ethan J. Rowin, Barry J. Maron, Konstantinos C. Siontis, Albree F. Tower-Rader, Daniele Massera, Benjamin Koethe, Ozlem Bilen, Dermot Phelan, Ahran Arnold, Jagdeep S. Mohal, et al.

    BACKGROUND: Implanted cardioverter-defibrillators (ICDs) have been used in patients with hypertrophic cardiomyopathy (HCM) to prevent sudden death, and have proven lifesaving for many patients. However, experience with ICD therapy has largely been derived from relatively small HCM cohorts confined to specific countries or regions of the world. Therefore, we sought to determine the effectiveness of ICDs in preventing sudden death due to life-threatening ventricular arrhythmias in a large international multicenter HCM population. METHODS: Databases from 25 HCM centers (8 in the United States, 9 in Europe, 4 in Asia, and 1 each in Australia, Africa, Mexico, and South America) were retrospectively interrogated to identify consecutive patients with HCM with ICDs (1992 to 2024) followed for 7±6 years (up to 32 years) for clinical outcomes. RESULTS: A total of 3387 patients were identified (63% men). They had a mean left ventricular thickness of 22±7 mm. The participants had received ICDs at a mean age of 47±17 years. Over follow-up, 550 patients (16%) experienced ≥1 appropriate ICD therapy (2.6%/y), including 86 of the 247 implanted for secondary prevention (35% [6.4%/y]) and 464 of the 3140 implanted for primary prevention (15% [2.2%/y]). Appropriate therapy occurred in the 464 primary prevention patients at a mean age of 49±17 years, with a median time to first appropriate therapy of 4 years after ICD implantation; 16% of these received their first appropriate therapy ≥10 years after implantation, and 47% experienced multiple interventions. Independent predictors of appropriate ICD therapy included unexplained syncope, left ventricular apical aneurysms, left ventricular systolic dysfunction, and nonsustained ventricular tachycardia on ambulatory monitoring. Of the 3140 primary prevention patients, 2946 survived (94%) and 194 died (6%) (0.8%/y), including 68 due to HCM (0.3%/y), predominantly of end-stage heart failure (n=43) or stroke (n=9). In contrast, 11 patients (0.4%) died suddenly, with device failures occurring in 2.4% of those with life-threatening ventricular tachyarrhythmias. Survival free from HCM-related mortality at 10 and 20 years was 97% and 91%, respectively. CONCLUSIONS: In this international multicenter study, the largest to date, including >3300 consecutive patients with HCM and ICDs, device therapy terminated potentially lethal ventricular tachyarrhythmias in 1 of 6 patients, with low HCM-related mortality rates for patients with ICDs. These novel data demonstrate the effectiveness of the ICD initiative, which has probably favorably altered the natural history of many patients with HCM worldwide.


  • Open Access

    High‐Precision Hemodynamic and Echocardiographic Assessment of Pacing in Obstructive Hypertrophic Cardiomyopathy

    by Jagdeep S. Mohal, Matthew J. Shun‐Shin, Kayla Chiew, Alejandra A. Miyazawa, Florentina Simader, Pannathorn Tangkongpanich, Rahul Bahl, Ji‐Jian Chow, James P. Howard, Akriti Naraen, et al.

    Background: Left ventricular outflow obstruction drives symptoms and outcomes in obstructive hypertrophic cardiomyopathy (oHCM). Right ventricular pacing (RVP) can desynchronize the left ventricle to relieve this and allows control of atrioventricular delay (AVD) but may impair ventricular function. We used high‐precision assessment to quantify the hemodynamic and echocardiographic effects of RVP in oHCM. Methods: Patients with oHCM and implanted dual‐chamber pacing devices underwent continuous recording of ECG, beat‐by‐beat outflow tract continuous wave Doppler, and beat‐by‐beat, noninvasive finger‐cuff blood pressure while pacing was alternated between atrium‐only pacing and AV‐sequential RVP at a range of AVDs at 5 bpm above resting heart rate and 100 bpm. Changes in systolic blood pressure (∆SBP) and left ventricular outflow tract gradient (∆LVOTg) were fitted to parabolas to produce reproducible, narrow confidence interval estimates of effects. Results: Twenty two patients were recruited (60% male, mean resting LVOTg 53 mmHg). At just above resting heart rate (mean 75 bpm), RVP produced mean peak ∆SBP from AAI to DDD of 2.47 mmHg (95% confidence interval: 0.19–4.76, p = 0.04). The mean AVD for peak ∆SBP was 173.2 ms. Mean LVOTg reduction at this AVD was 8.31 mmHg (2.43–14.18, p < 0.001). Apart from the hemodynamically optimum AVD, no other AVDs produced statistically significant increases in SBP. At 100 bpm, greater increases in SBP and reductions in LVOTg were seen at hemodynamically optimal AVD. Conclusion: Multiple alternation assessment allows precise, reproducible, narrow confidence interval quantification of hemodynamic and echocardiographic pacing effects. RVP can reduce LVOTg while preserving or improving cardiac output, but AVD is a key modifier of this relationship.


  • Open Access

    Therapeutic potential of conduction system pacing as a method for improving cardiac output during ventricular tachycardia

    by Daniel Keene, Alejandra A. Miyazawa, Ahran D. Arnold, Akriti Naraen, Nandita Kaza, Jagdeep S. Mohal, David C. Lefroy, Phang Boon Lim, Fu Siong Ng, Michael Koa-Wing, et al.

    Background: Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored the potential therapeutic utility of His bundle pacing to improve cardiac output during VT. Methods: Study 1 aimed to improve the understanding of mechanisms of harm during VT (using pacing simulated VT). In 23 patients with left ventricular impairment, we recorded continuous ECG and beat-by-beat blood pressure measurements. We assessed the hemodynamic impact of heart rate and restoration of atrial and biventricular synchrony. Study 2 investigated novel pacing interventions during clinical VT by evaluating the hemodynamic effects of His bundle pacing at 5 bpm above the VT rate in 10 patients. Results: In Study 1, at progressively higher rates of simulated VT, systolic blood pressure declined: at rates of 125, 160, and 190 bpm, -22.2%, -42.0%, and -58.7%, respectively (ANOVA p < 0.0001). Restoring atrial synchrony alone had only a modest beneficial effect on systolic blood pressure (+ 3.6% at 160 bpm, p = 0.2117), restoring biventricular synchrony alone had a greater effect (+ 9.1% at 160 bpm, p = 0.242), and simultaneously restoring both significantly increased systolic blood pressure (+ 31.6% at 160 bpm, p = 0.0003). In Study 2, the mean rate of clinical VT was 143 ± 21 bpm. His bundle pacing increased systolic blood pressure by + 14.2% (p = 0.0023). In 6 of 10 patients, VT terminated with His bundle pacing. Conclusions: Restoring atrial and biventricular synchrony improved hemodynamic function in simulated and clinical VT. Conduction system pacing could improve VT tolerability and treatment. Graphical

  • Open Access

    Catheter Ablation for Ventricular Tachycardia After MI: A Reconstructed Individual Patient Data Meta-analysis of Randomised Controlled Trials

    by Rohin K Reddy, James P Howard, Yousif Ahmad, Matthew J Shun-Shin, Florentina A Simader, Alejandra A Miyazawa, Keenan Saleh, Akriti Naraen, Jack W Samways, George Katritsis, et al.

    Background: The prognostic impact of ventricular tachycardia (VT) catheter ablation is an important outstanding research question. We undertook a reconstructed individual patient data meta-analysis of randomised controlled trials comparing ablation to medical therapy in patients developing VT after MI. Methods: We systematically identified all trials comparing catheter ablation to medical therapy in patients with VT and prior MI. The prespecified primary endpoint was reconstructed individual patient assessment of all-cause mortality. Prespecified secondary endpoints included trial-level assessment of all-cause mortality, VT recurrence or defibrillator shocks and all-cause hospitalisations. Prespecified subgroup analysis was performed for ablation approaches involving only substrate modification without VT activation mapping. Sensitivity analyses were performed depending on the proportion of patients with prior MI included. Results: Eight trials, recruiting a total of 874 patients, were included. Of these 874 patients, 430 were randomised to catheter ablation and 444 were randomised to medical therapy. Catheter ablation reduced all-cause mortality compared with medical therapy when synthesising individual patient data (HR 0.63; 95% CI [0.41–0.96]; p=0.03), but not in trial-level analysis (RR 0.91; 95% CI [0.67–1.23]; p=0.53; I2=0%). Catheter ablation significantly reduced VT recurrence, defibrillator shocks and hospitalisations compared with medical therapy. Sensitivity analyses were consistent with the primary analyses. Conclusion: In patients with postinfarct VT, catheter ablation reduces mortality.