Patrick F. Egan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Patrick F. Egan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Yuanchao Yang
National Institute of Metrology, Beijing, China
5 shared publications - Christopher W Meyer
National Institute for Standards and Technology (NIST), Bldg. 221, Rm. B131. 100 Bureau Dr. Gaithersburg, MD 20899, United States of America
1 shared publication Eric S Stanfield
National Institute of Standards and Technology, 100 Bureau Dr, Gaithersburg, MD 20899, United States of America
1 shared publicationFereydoun Lakestani
European Commission Joint Research Centre
1 shared publication- Jack A. Stone
National Institute of Standards and Technology
1 shared publication - John R. Stoup
National Institute of Standards and Technology
1 shared publication
Latest Publications
- Open Access
- 18 September 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (5) , 058002
Comment on ‘Electric polarizabilities of CH 4 , CO, and O 2 determined by an optical refractometer’
- 18 September 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (5) , 058002
Open AccessComment on ‘Electric polarizabilities of CH 4 , CO, and O 2 determined by an optical refractometer’
- Open Access
- 19 June 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (25) , 255003
Two-color measurements supporting a revised formulation for the refractive index of air
Two-color refractivity measurements are reported for carbon dioxide, oxygen, binary mixtures of nitrogen–oxygen, natural dry air, and water vapor. For the ‘dry’ gases, the measurements were simultaneously performed at 0.632 9908 μ m and 1.542 383 μ m , and cover temperatures ( 20 < t 90 < 100 ) ∘ C and pressures p < 0.5 MPa − 1 . For water vapor, the refractivity ratio was studied for six wavelengths ( 1.52 < λ < 1.57 ) μ m relative to a simultaneous measurement made at 0.632 9908 μ m . The carbon dioxide and oxygen measurements establish the molar refractivities and second density virial coefficients more accurately than anything done before. A Sellmeier equation is formulated for oxygen which is about 10 3 times more accurate than extant knowledge dating from 1932 . The nitrogen–oxygen measurements are used to derive the second density cross virial coefficient. The natural dry air measurements provide a targeted refinement to the Ciddor formulation for the refractive index of air, because they establish both a reference value for refractivity and the second density virial coefficient. The water vapor measurements ensure an accurate Ciddor formulation at telecom wavelengths, and guide the implementation of the group index.
- 19 June 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (25) , 255003
Open AccessTwo-color measurements supporting a revised formulation for the refractive index of air
Two-color refractivity measurements are reported for carbon dioxide, oxygen, binary mixtures of nitrogen–oxygen, natural dry air, and water vapor. For the ‘dry’ gases, the measurements were simultaneously performed at 0.632 9908 μ m and 1.542 383 μ m , and cover temperatures ( 20 < t 90 < 100 ) ∘ C and pressures p < 0.5 MPa − 1 . For water vapor, the refractivity ratio was studied for six wavelengths ( 1.52 < λ < 1.57 ) μ m relative to a simultaneous measurement made at 0.632 9908 μ m . The carbon dioxide and oxygen measurements establish the molar refractivities and second density virial coefficients more accurately than anything done before. A Sellmeier equation is formulated for oxygen which is about 10 3 times more accurate than extant knowledge dating from 1932 . The nitrogen–oxygen measurements are used to derive the second density cross virial coefficient. The natural dry air measurements provide a targeted refinement to the Ciddor formulation for the refractive index of air, because they establish both a reference value for refractivity and the second density virial coefficient. The water vapor measurements ensure an accurate Ciddor formulation at telecom wavelengths, and guide the implementation of the group index.
- Open Access
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
A prospectus on direct traceability to the kelvin for point-of-use applications
The revised definition of the kelvin has created new interest in alternative paths of traceability to the SI. In particular, the development of methods for the direct realization of the kelvin is ongoing, establishing traceability without the need to go through the international-consensus temperature scale, the ITS-90. These direct realization methods are in contrast to the ITS-90 and the measurement infrastructure of reference materials and artefact thermometer calibration chains. This infrastructure has been built up over a century or more of industrialization and scientific progress, and while very robust, is not well suited to address the requirements of the most demanding of application environments. We examine how direct traceability to the kelvin can be applied to address those applications and assess the relative practical merits of various direct realization approaches. Primary thermometry methods are surveyed from the standpoint of achievable uncertainties over the range 4 K to 1800 K with examples of practical direct-realization technologies. This assessment points to a narrow application space of long-term missions, or those occurring in remote or hazardous environments, as the most compelling cases for the direct realization approach. We present two special application environments where direct realizations are well suited for point-of-use temperature measurement. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
Open AccessA prospectus on direct traceability to the kelvin for point-of-use applications
The revised definition of the kelvin has created new interest in alternative paths of traceability to the SI. In particular, the development of methods for the direct realization of the kelvin is ongoing, establishing traceability without the need to go through the international-consensus temperature scale, the ITS-90. These direct realization methods are in contrast to the ITS-90 and the measurement infrastructure of reference materials and artefact thermometer calibration chains. This infrastructure has been built up over a century or more of industrialization and scientific progress, and while very robust, is not well suited to address the requirements of the most demanding of application environments. We examine how direct traceability to the kelvin can be applied to address those applications and assess the relative practical merits of various direct realization approaches. Primary thermometry methods are surveyed from the standpoint of achievable uncertainties over the range 4 K to 1800 K with examples of practical direct-realization technologies. This assessment points to a narrow application space of long-term missions, or those occurring in remote or hazardous environments, as the most compelling cases for the direct realization approach. We present two special application environments where direct realizations are well suited for point-of-use temperature measurement. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.
- 17 June 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 23 (6)
Demonstration of dispersion gas barometry
- 17 June 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 23 (6)
Demonstration of dispersion gas barometry
- Open Access
- 28 November 2024
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (12) , 1-2
Correction to: Optical $n(p,\ T_{90})$ Measurement Suite 1: He, Ar, and $\hbox {N}_2$- 28 November 2024
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (12) , 1-2
Open AccessCorrection to: Optical $n(p,\ T_{90})$ Measurement Suite 1: He, Ar, and $\hbox {N}_2$ - 7 November 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (6) , 065010
Wavemeter calibration by frequency comb
Upgrades to the vacuum wavelength calibration service at the National Institute of Standards and Technology are reported. The instrumentation centerpiece is an optical frequency comb stabilized to a GPS-disciplined oscillator, thereby providing direct traceability to the SI second. Historically, the service has covered lasers at the popular interferometry wavelengths red and green. Recently, capability has been added for calibrating wavemeters at multiple telecom wavelengths in the range ( 1520 < λ < 1570 ) nm . For most commercially available wavemeters, the test uncertainty ratio is about 104.
- 7 November 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (6) , 065010
Wavemeter calibration by frequency comb
Upgrades to the vacuum wavelength calibration service at the National Institute of Standards and Technology are reported. The instrumentation centerpiece is an optical frequency comb stabilized to a GPS-disciplined oscillator, thereby providing direct traceability to the SI second. Historically, the service has covered lasers at the popular interferometry wavelengths red and green. Recently, capability has been added for calibrating wavemeters at multiple telecom wavelengths in the range ( 1520 < λ < 1570 ) nm . For most commercially available wavemeters, the test uncertainty ratio is about 104.
- 7 October 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (6) , 065004
Conversion of a piston–cylinder dimensional dataset to the effective area of a mechanical pressure generator
Recent developments in diameter metrology at NIST have improved the dimensional characterization of piston–cylinder assemblies (PCAs) to unprecedented precision. For the newest generation of PCAs, the standard uncertainty in the measurement of the outer diameter is 12 nm , while uncertainty in the measurement of the inner diameter is 14 nm . With a high-accuracy dimensional dataset in hand, the task of determining the pressure generated by a specific PCA is reduced to converting the diameter (and straightness and roundness) to an effective area (and distortion coefficient). The details on how this was performed for the artifact PCA2062 are described. PCA2062 was dimensioned in 2017 and 2020; the area repeated within 0.2 × 10 − 6 ⋅ A 0 . The calculation produced estimates of fall rate and rotation decay that agreed with experimental observations within 12 %. The fall rate is proportional to the square of the gap width; therefore, the agreement between calculation and measurement validates the dimensional estimate of the gap width within ( 36 ± 42 ) nm , where the 42 nm standard uncertainty is governed by the present state of flow theory. The piston gage model is buttressed by three comparison tests against a laser barometer, which support a view that PCA2062 is linear and reproducible within 0.2 μ Pa Pa − 1 . Finally, an estimate of uncertainty in the effective area of a dimensioned artifact is provided: as expected, the diameter measurement is the main culprit, but there are open questions regarding the flow model that preclude an accurate evaluation of the distortion coefficient. For the 530 kPa operating range of PCA2062, distortion is not a significant problem, but the effect would be dominant in assemblies operating at 1 MPa and above.
- 7 October 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (6) , 065004
Conversion of a piston–cylinder dimensional dataset to the effective area of a mechanical pressure generator
Recent developments in diameter metrology at NIST have improved the dimensional characterization of piston–cylinder assemblies (PCAs) to unprecedented precision. For the newest generation of PCAs, the standard uncertainty in the measurement of the outer diameter is 12 nm , while uncertainty in the measurement of the inner diameter is 14 nm . With a high-accuracy dimensional dataset in hand, the task of determining the pressure generated by a specific PCA is reduced to converting the diameter (and straightness and roundness) to an effective area (and distortion coefficient). The details on how this was performed for the artifact PCA2062 are described. PCA2062 was dimensioned in 2017 and 2020; the area repeated within 0.2 × 10 − 6 ⋅ A 0 . The calculation produced estimates of fall rate and rotation decay that agreed with experimental observations within 12 %. The fall rate is proportional to the square of the gap width; therefore, the agreement between calculation and measurement validates the dimensional estimate of the gap width within ( 36 ± 42 ) nm , where the 42 nm standard uncertainty is governed by the present state of flow theory. The piston gage model is buttressed by three comparison tests against a laser barometer, which support a view that PCA2062 is linear and reproducible within 0.2 μ Pa Pa − 1 . Finally, an estimate of uncertainty in the effective area of a dimensioned artifact is provided: as expected, the diameter measurement is the main culprit, but there are open questions regarding the flow model that preclude an accurate evaluation of the distortion coefficient. For the 530 kPa operating range of PCA2062, distortion is not a significant problem, but the effect would be dominant in assemblies operating at 1 MPa and above.
- Open Access
- 11 September 2024
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (9) , 1-23
Expansivity of Fused Quartz Glass Measured Within $6 \times 10^{-10}\,\text{K}^{-1}$A method is described to measure the thermal expansion coefficient of fused quartz glass. The measurement principle is to monitor the change in resonance frequency of a Fabry–Perot cavity as its temperature changes; the Fabry–Perot cavity is made from fused quartz glass. The standard uncertainty in the measurement was less than 0.6 $$(\textrm{nm}{\cdot } \textrm{m}^{-1}){\cdot }\textrm{K}^{-1}$$ , or 0.15 %. The limit on performance is arguably uncertainty in the reflection phase-shift temperature dependence, because neither thermooptic nor thermal expansion coefficients of thin-film coatings are reliably known. However, several other uncertainty contributors are at the same level of magnitude, and so any improvement in performance would entail significant effort. Furthermore, measurements of three different samples revealed that material inhomogeneity leads to differences in the effective thermal expansion coefficient of fused quartz; inhomogeneity in thermal expansion among samples is 24 times larger than the measurement uncertainty in a single sample.- 11 September 2024
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (9) , 1-23
Open AccessExpansivity of Fused Quartz Glass Measured Within $6 \times 10^{-10}\,\text{K}^{-1}$A method is described to measure the thermal expansion coefficient of fused quartz glass. The measurement principle is to monitor the change in resonance frequency of a Fabry–Perot cavity as its temperature changes; the Fabry–Perot cavity is made from fused quartz glass. The standard uncertainty in the measurement was less than 0.6 $$(\textrm{nm}{\cdot } \textrm{m}^{-1}){\cdot }\textrm{K}^{-1}$$ , or 0.15 %. The limit on performance is arguably uncertainty in the reflection phase-shift temperature dependence, because neither thermooptic nor thermal expansion coefficients of thin-film coatings are reliably known. However, several other uncertainty contributors are at the same level of magnitude, and so any improvement in performance would entail significant effort. Furthermore, measurements of three different samples revealed that material inhomogeneity leads to differences in the effective thermal expansion coefficient of fused quartz; inhomogeneity in thermal expansion among samples is 24 times larger than the measurement uncertainty in a single sample. - Open Access
- 3 August 2024
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (8) , 1-17
Optical n(p, T90) Measurement Suite 3: Results at $\lambda = 1542\,\text{nm}$Single-isotherm n(p, T90) results are reported for the gases Ar, N2, H2O, and D2O at vacuum wavelength $$\lambda = 1542.383(1)$$ nm. The argon and nitrogen isotherms were measured near 303 K; the water isotherms were measured near 373 K. Combined with the two previous articles of this series, the present results beget several insights via dispersion analyses. The argon result is highly consistent with static measurement plus ab initio calculation of dispersion polarizability. The nitrogen result is nominally consistent with one recent experiment and the dipole oscillator strength distributions, but the present work offers a refined estimate of the molar refractivity at optical wavelengths. For ordinary and heavy water, the dispersion trend is nominally consistent with existing liquid measurements. However, water’s absorption features in the near-infrared preclude a reliable comparison of the present result with literature.- 3 August 2024
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (8) , 1-17
Open AccessOptical n(p, T90) Measurement Suite 3: Results at $\lambda = 1542\,\text{nm}$Single-isotherm n(p, T90) results are reported for the gases Ar, N2, H2O, and D2O at vacuum wavelength $$\lambda = 1542.383(1)$$ nm. The argon and nitrogen isotherms were measured near 303 K; the water isotherms were measured near 373 K. Combined with the two previous articles of this series, the present results beget several insights via dispersion analyses. The argon result is highly consistent with static measurement plus ab initio calculation of dispersion polarizability. The nitrogen result is nominally consistent with one recent experiment and the dipole oscillator strength distributions, but the present work offers a refined estimate of the molar refractivity at optical wavelengths. For ordinary and heavy water, the dispersion trend is nominally consistent with existing liquid measurements. However, water’s absorption features in the near-infrared preclude a reliable comparison of the present result with literature. - Open Access
- 28 May 2024
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (6) , 1-26
Optical $n(p,\ T_{90})$ Measurement Suite 2: H$_2$O and D$_2$OA suite of measurements of refractive index $$n(p,\ T_{90})$$ is reported for gas phase ordinary water H $$_2$$ O and heavy water D $$_2$$ O. The methodology is optical refractive index gas metrology, operating at laser wavelength $$633\ \text {nm}$$ and covering the range $$(293< T_{90} < 433)\ \text {K}$$ and $$p < 2\ \text {kPa}$$ . A key output of the work is the determination of molar polarizabilities $$A_{\text {R}} = 3.7466(18) \cdot [1 + 1.5(6) \times 10^{-6} (T/\text {K} - 303) ]\ \text{cm}^3 \cdot \text{mol}^{-1}$$ for ordinary water, and $$A_{\text {R}} = 3.7135(18) \cdot [1 + 4.4(10) \times 10^{-6} (T/\text {K} - 303) ]\ \text{cm}^3 \cdot \text{mol}^{-1}$$ for heavy water, with the numbers in parentheses expressing standard uncertainty. For heavy water, this work appears to be only the second gas phase measurement to date. For both ordinary and heavy water, this work agrees within $$0.15\ \%$$ with recent ab initio theoretical results for $$A_{\text {R}}$$ , but the comparison is affected by imperfect knowledge of dispersion. For ordinary water, the close agreement between the present work and theory suggests problems at the $$2\ \%$$ level in the low density limit of the reference formulation for refractivity.- 28 May 2024
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (6) , 1-26
Open AccessOptical $n(p,\ T_{90})$ Measurement Suite 2: H$_2$O and D$_2$OA suite of measurements of refractive index $$n(p,\ T_{90})$$ is reported for gas phase ordinary water H $$_2$$ O and heavy water D $$_2$$ O. The methodology is optical refractive index gas metrology, operating at laser wavelength $$633\ \text {nm}$$ and covering the range $$(293< T_{90} < 433)\ \text {K}$$ and $$p < 2\ \text {kPa}$$ . A key output of the work is the determination of molar polarizabilities $$A_{\text {R}} = 3.7466(18) \cdot [1 + 1.5(6) \times 10^{-6} (T/\text {K} - 303) ]\ \text{cm}^3 \cdot \text{mol}^{-1}$$ for ordinary water, and $$A_{\text {R}} = 3.7135(18) \cdot [1 + 4.4(10) \times 10^{-6} (T/\text {K} - 303) ]\ \text{cm}^3 \cdot \text{mol}^{-1}$$ for heavy water, with the numbers in parentheses expressing standard uncertainty. For heavy water, this work appears to be only the second gas phase measurement to date. For both ordinary and heavy water, this work agrees within $$0.15\ \%$$ with recent ab initio theoretical results for $$A_{\text {R}}$$ , but the comparison is affected by imperfect knowledge of dispersion. For ordinary water, the close agreement between the present work and theory suggests problems at the $$2\ \%$$ level in the low density limit of the reference formulation for refractivity.