GBGiovanni Francesco Baresi

Giovanni Francesco Baresi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Giovanni Francesco Baresi has a total of 80 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    International Cross Sectional Survey on the Management of Visceral Artery Aneurysms and Isolated Dissections from the European Visceral Artery Revascularisation (EVisAR) Study Participants

    by Nicola Leone, Mario D’ORia, George A. Antoniou, Mark J. Koelemay, Elena Iborra, Jos C. van Den Berg, Sonia Ronchey, Giovanni F. Baresi, Alexander Gombert, Stefano Gennai, et al.

  • Open Access

    International Cross Sectional Survey on Management of Mesenteric Arterial Ischaemia and Renal Artery Stenosis from the European Visceral Artery Revascularisation Study Participants

    by Nicola Leone, Mario D’ORia, Georgios Antoniou, Mark J. Koelemay, Jorg L. De Bruin, Sonia Ronchey, Giovanni F. Baresi, Desiree van Noord, Alexander Gombert, Stefano Gennai

  • Open Access

    Catheter-Based Renal Denervation in Acute Type B Aortic Dissection to Optimize Long-Term Pressure Control

    by Giovanni Francesco Baresi, Andrea Melloni, Stefano Bonardelli, Luca Bertoglio

  • Risk Factors and Perioperative Outcomes of Postimplantation Syndrome After Thoracic Endovascular Aortic Repair

    by Nicola Leone, Luigi Alberto Maria Bartolotti, Mattia Migliari, Andrea Ferri, Giovanni Francesco Baresi, Francesco Andreoli, Giuseppe Saitta, Stefano Gennai

    Objective: Postimplantation syndrome (PIS) is a systemic inflammatory response that occurs following abdominal endovascular aortic repair (EVAR) and thoracic EVAR (TEVAR). The main outcome was to individuate the incidence and risk factors of PIS after TEVAR. Its impact on the length of stay and clinical outcomes were secondary objectives. Materials and Methods: Three hundred sixty-nine consecutive TEVAR procedures performed between February 2010 and November 2022 were included in this retrospective cohort, observational, single-center study. Patients with proximal landing in zones 0 to 5 were enrolled. Data on comorbidities, previous aortic surgery and morphology, thoracic aorta coverage, stent-graft composition, intraoperative variables, and postoperative outcomes were collected. White blood cell (WBC) and C-reactive protein (CRP) serum levels were recorded preoperatively and 48 hours after TEVAR. PIS was defined as the concomitant presence of fever (tympanic temperature ≥38.0°C), CRP serum level >0.7 mg/dl and evidence of pleural effusion on postoperative chest radiograph. Results: PIS incidence in our cohort was 26.8%. PIS patients presented with a higher rate of hyperlipidemia (56.6% vs 44.8%, p = 0.045) than non-PIS patients. Stent-graft composition did not play a relevant role in eliciting PIS. PIS was a statistically significant factor in prolonging patients’ stay (median 16.0 days vs 8.0 days, p < 0.001, PIS and non-PIS patients). Thoracic aortic coverage >150 mm (Odds Ratio (OR) 4.7, p = 0.004), coronary artery disease (OR 2.1, p = 0.028), and preoperative WBC count (OR 1.1, p = 0.047) were identified as risk factors for PIS, whereas previous aortic surgery (OR 0.5, p = 0.05) was highlighted as a protective factor. Thoracic aortic coverage was a significant risk factor for increased WBC and CRP levels (p < 0.001). Conclusion: PIS incidence was 26.8% in our cohort. Thoracic aortic coverage, coronary artery disease, and preoperative WBC count were identified as risk factors for PIS after TEVAR, whereas previous aortic surgery was found to be a protective factor. PIS also appeared to have a significant impact on length of stay. Clinical Impact: This study identified a significant occurrence of post-implantation syndrome (PIS) following TEVAR, affecting over 25% of patients and adversely affecting the duration of hospital stay. Stent graft material did not seem to influence the incidence of PIS. Thoracic aortic coverage, coronary artery disease, and preoperative white blood cell (WBC) count have been identified as risk factors, whereas previous aortic surgery has been found to serve as a protective factor, representing a novel finding in the literature. Further research is warranted to ascertain strategies for mitigating the incidence of PIS, considering the risk factors identified in both current and prior studies. In addition, it is necessary to evaluate the potential implementation of preoperative prophylactic therapy for PIS in patients undergoing TEVAR.


  • Visceral artery aneurysms: A shred of light on rare entities

    by Nicola Leone, Mattia Migliari, Giovanni F. Baresi, Stefano Gennai

    Visceral artery aneurysms (VAAs) and pseudoaneurysms are rare but clinically significant vascular pathologies with potentially fatal complications including rupture. VAAs are often asymptomatic and frequently discovered incidentally during imaging performed for unrelated reasons. Their pathophysiology, clinical presentation, and management vary based on the etiology, anatomical location, and patient-specific factors. The prognosis for conservatively managed VAAs is generally favorable, with slow growth rates and low rupture risks. However, pseudoaneurysms, often associated with trauma or pancreatitis, carry a much higher rupture risk and typically require early intervention, regardless of size. Endovascular techniques have progressively replaced open surgery as the preferred treatment approach due to lower complication rates and comparable long-term outcomes. However, current knowledge is biased by the scarcity of high-quality evidence regarding the natural history, rupture risk, and optimal management of VAAs and pseudoaneurysms, largely due to the rarity of these conditions. Consequently, different international societies have provided recommendations with low strength and, in some cases, conflicting indications.


  • Long-term Clinical Outcomes and Predictors of Type-III Endoleak in a Large Cohort of Patients Treated With Anatomically Fixed Stent Grafts Over 20 Years

    by Nicola Leone, Francesco Andreoli, Giovanni Francesco Baresi, Andrea Ferri, Luigi Alberto Maria Bartolotti, Giuseppe Marcello Saitta, Roberto Silingardi, Stefano Gennai

    Objective: To assess the incidence, outcomes, and predictors of type III endoleaks (TIIIELs) in patients treated with different generations of Endologix unibody devices for abdominal aortic aneurysm (AAA). Methods: Patients treated with unibody endografts between 1999 and 2020 in a single unit were prospectively enrolled, retrospectively analyzed, and stratified according to device generation. The primary outcome was the incidence of TIIIEL in patients treated with unibody devices. Secondary outcomes included: (1) TIIIEL incidence among the different device generations; (2) comparison of type IIIa (TIIIaELs) and type IIIb endoleaks (TIIIbELs) incidence, treatment, and complications; (3) risk factor analysis for TIIIEL; (4) overall survival and survival free from TIIIEL. Results: A total of 872 patients who underwent endovascular aortic repair (EVAR) were analyzed. The cumulative incidence of TIIIEL was 4.8% (42/872). The incidence among different generations was 2.4% (10/414), 21.7% (15/69), and 4.6% (16/341), and 2.1% (1/48) for Powerlink, AFXs, AFXd, and AFX2. Freedom from TIIIEL by device generation was significantly lower in the AFXs group (p<0.001). Type III endoleaks was higher in urgent EVAR (p=0.011), large AAA (p<0.001), angulated and calcified necks (p=0.002), and when more than one modular component or non-proprietary extension was used (p<0.001). AFXs was found as independent risk factor for TIIIEL (hazard ratio [HR]=3.1, p=0.003), while the use of a single component decreased the risk (HR=0.3, p=0.005). Finally, every 10-mm increase in AAA diameter resulted in a 2-fold increase in TIIIEL risk (HR=2.0, p<0.001). Conclusion: The first generation of AFX endograft was associated with an increase in TIIIEL risk by 3.1 times, claiming a strict and careful follow-up in patients implanted with this device. Clinical Impact: The old-generation of unibody endograft AFXs was associated with an increase in TIIIEL risk by 3.1 times. Angulated and calcified neck, large aneurysms and the use of nonproprietary graft extension were found as independent risk factors for TIIIEL. Patients implanted with these devices and with these anatomical features should be intensively monitored during follow-up.


  • In-Stent Restenosis after Carotid Artery Stent Placement Comparing Maximum Plaque Predilation and Postdilation

    by Leone Nicola, Baresi Giovanni Francesco, Covic Tea, Pizzarelli Ginevra, Lauricella Antonio, Silingardi Roberto, Gennai Stefano


  • Anatomical suitability for branched endovascular aortic arch repair and balloon-expandable bridging stent grafts in a cohort of patients previously treated with a hybrid approach

    by Nicola Leone, Luigi Alberto Maria Bartolotti, Giovanni Francesco Baresi, Roberto Silingardi, Timothy Andrew Resch, Stefano Gennai