Xu Dai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xu Dai has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Yuan Yuan
College of Materials Science and Engineering Chongqing University Chongqing China
9 shared publications - Ruijin Liao
Chongqing University
8 shared publications Huiying Xiang
State Grid Chongqing Electric Power Research Institute, Chongqing, China
4 shared publications- Bo Li
Institute of Electric Power Science of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
3 shared publications - Cheng Zhang
College of Materials Science and Engineering, Chongqing University, Chongqing 400044, China
3 shared publications - Guoyong Liu
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China
2 shared publications
Latest Publications
- Open Access
Effects of Different Nanoporous Structures on the Heat Dissipation and Temperature-Rising Properties of Al Conductors
Increasing the ampacity of transmission lines can ensure safe operation while simultaneously achieving higher transmission capacity and energy-saving goals. Using a high-infrared-emissivity surface is an effective approach to enhancing the heat-dissipation performance of conductors and enabling low-cost capacity upgrades. In this study, a nanoporous structure was constructed on the surface of aluminum conductors by anodization. The influences of different pore diameters and pore depths on the infrared emissivity and current-induced temperature rise characteristics were systematically compared, and the optimal structure was fabricated on aluminum stranded conductors for performance validation. The results show that the nanoporous aluminum stranded conductor with a pore diameter of approximately 100 nm and a pore depth of approximately 30 μm achieves the highest ampacity, with a 26.6% increase compared with the bare aluminum stranded conductor. The improvement can be attributed to (1) enhancing thermal emissivity to strengthen radiative cooling, and (2) increasing the effective surface area to promote convective heat transfer. Therefore, the as-prepared nanoporous aluminum stranded conductor exhibits excellent heat dissipation performance and demonstrates promising application potential in the capacity upgrading of transmission conductors.
Open AccessEffects of Different Nanoporous Structures on the Heat Dissipation and Temperature-Rising Properties of Al Conductors
Increasing the ampacity of transmission lines can ensure safe operation while simultaneously achieving higher transmission capacity and energy-saving goals. Using a high-infrared-emissivity surface is an effective approach to enhancing the heat-dissipation performance of conductors and enabling low-cost capacity upgrades. In this study, a nanoporous structure was constructed on the surface of aluminum conductors by anodization. The influences of different pore diameters and pore depths on the infrared emissivity and current-induced temperature rise characteristics were systematically compared, and the optimal structure was fabricated on aluminum stranded conductors for performance validation. The results show that the nanoporous aluminum stranded conductor with a pore diameter of approximately 100 nm and a pore depth of approximately 30 μm achieves the highest ampacity, with a 26.6% increase compared with the bare aluminum stranded conductor. The improvement can be attributed to (1) enhancing thermal emissivity to strengthen radiative cooling, and (2) increasing the effective surface area to promote convective heat transfer. Therefore, the as-prepared nanoporous aluminum stranded conductor exhibits excellent heat dissipation performance and demonstrates promising application potential in the capacity upgrading of transmission conductors.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41  (2) , 522-533
Experimental Studies on Anti-Icing Properties of Anodized Conductors With Nanoporous Structures in Natural Environments
Anti-icing materials and conductors have been reported to exhibit icephobicity in laboratory conditions. However, practical engineering applications pose two significant challenges: i) the extended duration of natural icing (3-4 days) causes non-equivalence with short-term laboratory tests; ii) varied ice types make laboratory results hardly replicable to natural ice accretion. Here, anodized conductors with nanoporous structures were fabricated to achieve the desired anti-icing properties under the prolonged low-temperature and high-humidity natural icing conditions, even after one year of outdoor exposure. Notably, the anodized conductor demonstrated a significant reduction in ice weight during a full atmospheric icing period (150 hours), while also achieving effective ice-weight mitigation in the second-year tests, which involved 48 hours of glaze ice and 75 hours of hard-rime deposition. Moreover, the anodized conductor was implemented and validated on an operational 35 kV transmission line (several hundred meters). Meanwhile, field assessments on the electrical performance of the anodized ACSRs under the high-altitude natural environment validated improvements in corona inception voltages and heat dissipation at rated currents compared to bare ACSRs. Therefore, the proposed conductor represents a viable alternative to traditional overhead lines, promising effective icing mitigation and energy-efficient high-voltage transmission.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41  (2) , 522-533
Experimental Studies on Anti-Icing Properties of Anodized Conductors With Nanoporous Structures in Natural Environments
Anti-icing materials and conductors have been reported to exhibit icephobicity in laboratory conditions. However, practical engineering applications pose two significant challenges: i) the extended duration of natural icing (3-4 days) causes non-equivalence with short-term laboratory tests; ii) varied ice types make laboratory results hardly replicable to natural ice accretion. Here, anodized conductors with nanoporous structures were fabricated to achieve the desired anti-icing properties under the prolonged low-temperature and high-humidity natural icing conditions, even after one year of outdoor exposure. Notably, the anodized conductor demonstrated a significant reduction in ice weight during a full atmospheric icing period (150 hours), while also achieving effective ice-weight mitigation in the second-year tests, which involved 48 hours of glaze ice and 75 hours of hard-rime deposition. Moreover, the anodized conductor was implemented and validated on an operational 35 kV transmission line (several hundred meters). Meanwhile, field assessments on the electrical performance of the anodized ACSRs under the high-altitude natural environment validated improvements in corona inception voltages and heat dissipation at rated currents compared to bare ACSRs. Therefore, the proposed conductor represents a viable alternative to traditional overhead lines, promising effective icing mitigation and energy-efficient high-voltage transmission.
- 10 December 2024
- Published by Springer Nature
- p. 208-215
Studies on the Droplet Impact Behavior and Anti-Icing Properties on the Slippery Lubricant-Infused Porous Surface (SLIPS) of Al Conductors
- 10 December 2024
- Published by Springer Nature
- p. 208-215
Studies on the Droplet Impact Behavior and Anti-Icing Properties on the Slippery Lubricant-Infused Porous Surface (SLIPS) of Al Conductors
- Open Access
A Superhydrophobic Anti-Icing Surface with a Honeycomb Nanopore Structure
Recently, the icing disaster of transmission lines has been a serious threat to the safe operation of the power system. A superhydrophobic (SHP) anti-icing surface with a honeycomb nanopore structure was constructed using anodic oxidation technology combined with a vacuum infusion process. When the current density was 87.5 mA/cm2, the honeycomb porous surface had the best superhydrophobic performance (excellent water mobility), lowest ice-adhesion strength (0.7 kPa) and best anti-frosting performance. Compared with other types of alumina surfaces, the ice-adhesion strength of the SHP surface (87.5 mA/cm2) was only 0.2% of that of the bare surface. The frosting time of the SHP surface (87.5 mA/cm2) was 150 min, which was much slower. The former is attributed to the air cushion within the porous structure and the stress concentration, and the latter is attributed to the self-transition of the droplets and low solid–liquid heat transfer area. After 100 icing or frosting cycles, the SHP surface (87.5 mA/cm2) maintained a low ice-adhesion strength and superhydrophobic performance. This is because the anodic oxidation process forms a hard porous film, and the nano porous structure with a high aspect ratio can store modifiers to realize self-healing. The results indicate that the SHP surface with a honeycomb nanopore structure presents excellent anti-icing performance and durability.
Open AccessA Superhydrophobic Anti-Icing Surface with a Honeycomb Nanopore Structure
Recently, the icing disaster of transmission lines has been a serious threat to the safe operation of the power system. A superhydrophobic (SHP) anti-icing surface with a honeycomb nanopore structure was constructed using anodic oxidation technology combined with a vacuum infusion process. When the current density was 87.5 mA/cm2, the honeycomb porous surface had the best superhydrophobic performance (excellent water mobility), lowest ice-adhesion strength (0.7 kPa) and best anti-frosting performance. Compared with other types of alumina surfaces, the ice-adhesion strength of the SHP surface (87.5 mA/cm2) was only 0.2% of that of the bare surface. The frosting time of the SHP surface (87.5 mA/cm2) was 150 min, which was much slower. The former is attributed to the air cushion within the porous structure and the stress concentration, and the latter is attributed to the self-transition of the droplets and low solid–liquid heat transfer area. After 100 icing or frosting cycles, the SHP surface (87.5 mA/cm2) maintained a low ice-adhesion strength and superhydrophobic performance. This is because the anodic oxidation process forms a hard porous film, and the nano porous structure with a high aspect ratio can store modifiers to realize self-healing. The results indicate that the SHP surface with a honeycomb nanopore structure presents excellent anti-icing performance and durability.
- Open Access
Effects of the Second Anodization Parameters on the Hydrophobicity and Anti-Icing Properties of Al Surface with Composite Nanopore Structure
Icing on transmission lines often causes potential electric damage in power systems. Superhydrophobic anodized Al conductors have been proposed to have good anti-icing properties. In this study, superhydrophobic anodized Al conductors with composite nanopore structures were prepared by a two-step anodization. The microstructure, hydrophobicity, and anti-icing properties of composite nanopore structures were compared and studied. The optimal preparation parameter was determined as a current density of 0.04375 A/cm2 and anodization time of 15 min. Compared with the bare substrate, the optimal anodized Al surface of the composite nanopore structures show excellent hydrophobic and anti-icing properties, including a contact angle of 173°, a contact angle hysteresis of 0.122°, an ice adhesion strength of 0.71 kPa, and a glaze icing weight of 0.1 g after the 8 h. Therefore, the prepared anodized Al surface of composite nanopore structures with good anti-icing properties has profound application potential for overhead transmission lines.
Open AccessEffects of the Second Anodization Parameters on the Hydrophobicity and Anti-Icing Properties of Al Surface with Composite Nanopore Structure
Icing on transmission lines often causes potential electric damage in power systems. Superhydrophobic anodized Al conductors have been proposed to have good anti-icing properties. In this study, superhydrophobic anodized Al conductors with composite nanopore structures were prepared by a two-step anodization. The microstructure, hydrophobicity, and anti-icing properties of composite nanopore structures were compared and studied. The optimal preparation parameter was determined as a current density of 0.04375 A/cm2 and anodization time of 15 min. Compared with the bare substrate, the optimal anodized Al surface of the composite nanopore structures show excellent hydrophobic and anti-icing properties, including a contact angle of 173°, a contact angle hysteresis of 0.122°, an ice adhesion strength of 0.71 kPa, and a glaze icing weight of 0.1 g after the 8 h. Therefore, the prepared anodized Al surface of composite nanopore structures with good anti-icing properties has profound application potential for overhead transmission lines.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38  (6) , 4489-4500
Experimental Studies of a Novel Anti-Icing Aluminum Conductor With Excellent Durability and Improved Electrical Performance
Icing on transmission lines greatly threatens the operation and security of power systems. In this study, a novel durable anti-icing aluminum (Al) conductor is first proposed for its robust anti-icing properties and improved electrical performance. The novel Al conductor with optimized nanopores structure fabricated by anodization presented excellent superhydrophobicity with a contact angle of 176.83° and a contact angle hysteresis of 0.55°. Meanwhile, the ultra-low ice adhesion (1.75 kPa) of novel Al conductors, which is less than 1% of that of bare Al conductors, showed potential for self-de-icing behavior in glaze ice. Novel conductors also exhibited thinner glaze ice accretion of 5.84 g, than that of bare conductors (62.70 g). Additionally, the durability of novel conductors was examined in 100 times frosting/defrosting cycles, 100 times icing/de-icing cycles and 900 times abrasion processes. The mechanisms of robust durability were attributed to the excellent wear resistance and the continuous replenishment of modification agents. Fortunately, the good electrical performance of novel conductors in operation including the corona performance and line loss was experimental measured and validated by previous numerical theoretical calculations. In this study, the novel anti-icing Al conductors show profound application potential in high-voltage transmission fields.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38  (6) , 4489-4500
Experimental Studies of a Novel Anti-Icing Aluminum Conductor With Excellent Durability and Improved Electrical Performance
Icing on transmission lines greatly threatens the operation and security of power systems. In this study, a novel durable anti-icing aluminum (Al) conductor is first proposed for its robust anti-icing properties and improved electrical performance. The novel Al conductor with optimized nanopores structure fabricated by anodization presented excellent superhydrophobicity with a contact angle of 176.83° and a contact angle hysteresis of 0.55°. Meanwhile, the ultra-low ice adhesion (1.75 kPa) of novel Al conductors, which is less than 1% of that of bare Al conductors, showed potential for self-de-icing behavior in glaze ice. Novel conductors also exhibited thinner glaze ice accretion of 5.84 g, than that of bare conductors (62.70 g). Additionally, the durability of novel conductors was examined in 100 times frosting/defrosting cycles, 100 times icing/de-icing cycles and 900 times abrasion processes. The mechanisms of robust durability were attributed to the excellent wear resistance and the continuous replenishment of modification agents. Fortunately, the good electrical performance of novel conductors in operation including the corona performance and line loss was experimental measured and validated by previous numerical theoretical calculations. In this study, the novel anti-icing Al conductors show profound application potential in high-voltage transmission fields.
- 6 July 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15  (28) , 34215-34229
Anti-Icing Mechanism for a Novel Slippery Aluminum Stranded Conductor
The icing of transmission conductor seriously threatens the safe operation of power grids. Slippery lubricant-infused porous surface (SLIPS) has shown great potential for anti-icing applications. However, aluminum stranded conductors have complex surfaces, and the current SLIPSs are almost prepared and studied on small flat plates. Herein, the construction of SLIPS on the conductor was realized through anodic oxidation and the anti-icing mechanism of the slippery conductor was studied. Compared to the untreated conductor, the SLIPS-conductor reduces the icing weight by 77% in the glaze icing test and shows very low ice-adhesion strength (7.0 kPa). The excellent anti-icing performance of the slippery conductor is attributed to the droplet impact dynamics, icing delay, and lubricant stability. The dynamic behavior of water droplets is most affected by the complex shape of the conductor surface. Specifically, the impact of the droplet on the conductor surface is asymmetric and the droplet can slide along the depression in low-temperature and high-humidity environments. The stable lubricant of SLIPS increases both the nucleation energy barriers and the heat transfer resistance, which greatly delays the freezing time of droplets. Besides, the nanoporous substrate, the compatibility of the substrate with the lubricant, and the lubricant characteristics contribute to the lubricant stability. This work provides theoretical and experimental guidance on anti-icing strategies for transmission lines.
- 6 July 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15  (28) , 34215-34229
Anti-Icing Mechanism for a Novel Slippery Aluminum Stranded Conductor
The icing of transmission conductor seriously threatens the safe operation of power grids. Slippery lubricant-infused porous surface (SLIPS) has shown great potential for anti-icing applications. However, aluminum stranded conductors have complex surfaces, and the current SLIPSs are almost prepared and studied on small flat plates. Herein, the construction of SLIPS on the conductor was realized through anodic oxidation and the anti-icing mechanism of the slippery conductor was studied. Compared to the untreated conductor, the SLIPS-conductor reduces the icing weight by 77% in the glaze icing test and shows very low ice-adhesion strength (7.0 kPa). The excellent anti-icing performance of the slippery conductor is attributed to the droplet impact dynamics, icing delay, and lubricant stability. The dynamic behavior of water droplets is most affected by the complex shape of the conductor surface. Specifically, the impact of the droplet on the conductor surface is asymmetric and the droplet can slide along the depression in low-temperature and high-humidity environments. The stable lubricant of SLIPS increases both the nucleation energy barriers and the heat transfer resistance, which greatly delays the freezing time of droplets. Besides, the nanoporous substrate, the compatibility of the substrate with the lubricant, and the lubricant characteristics contribute to the lubricant stability. This work provides theoretical and experimental guidance on anti-icing strategies for transmission lines.
- 16 June 2023
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 306, 128073
Enhanced corrosion resistance of slippery liquid infused porous aluminum surfaces prepared by anodizing in simulated marine atmosphere
- 16 June 2023
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 306, 128073
Enhanced corrosion resistance of slippery liquid infused porous aluminum surfaces prepared by anodizing in simulated marine atmosphere
- Open Access
A Review on Superhydrophobic Surface with Anti-Icing Properties in Overhead Transmission Lines
The icing on overhead transmission lines is one of the largest threats to the safe operation of electric power systems. Compared with other security accidents in the electric industry, a sudden ice disaster could cause the most serious losses to electric power grids. Among the numerous de-icing and anti-icing techniques for application, direct current ice-melting and mechanical de-icing schemes require power cuts and other restrictive conditions. Superhydrophobic coating technology has been widely focused for good anti-icing properties, low cost and wide application range. However, the special structure of curved transmission lines, complicated service environments, and variated electric performance could significantly limit the application of superhydrophobic anti-icing coatings on overhead transmission lines. In particular, superhydrophobic surfaces can be achieved by combining the rough micro-nano structure and modification agents with low surface energy. Compared with superhydrophobic coatings, superhydrophobic surfaces will not increase the weight of the substrate and have good durability and stability in maintaining the robust structure to repeatedly resist aging, abrasion, corrosion and corona damages, etc. Therefore, this review summarizes the theoretical basis of anti-icing behavior and mechanisms, influencing factors of anti-icing properties, potential techniques of superhydrophobic surfaces on transmission lines, and, finally, presents future development challenges and prospects of superhydrophobic surfaces in the anti-icing protection of overhead transmission lines.
Open AccessA Review on Superhydrophobic Surface with Anti-Icing Properties in Overhead Transmission Lines
The icing on overhead transmission lines is one of the largest threats to the safe operation of electric power systems. Compared with other security accidents in the electric industry, a sudden ice disaster could cause the most serious losses to electric power grids. Among the numerous de-icing and anti-icing techniques for application, direct current ice-melting and mechanical de-icing schemes require power cuts and other restrictive conditions. Superhydrophobic coating technology has been widely focused for good anti-icing properties, low cost and wide application range. However, the special structure of curved transmission lines, complicated service environments, and variated electric performance could significantly limit the application of superhydrophobic anti-icing coatings on overhead transmission lines. In particular, superhydrophobic surfaces can be achieved by combining the rough micro-nano structure and modification agents with low surface energy. Compared with superhydrophobic coatings, superhydrophobic surfaces will not increase the weight of the substrate and have good durability and stability in maintaining the robust structure to repeatedly resist aging, abrasion, corrosion and corona damages, etc. Therefore, this review summarizes the theoretical basis of anti-icing behavior and mechanisms, influencing factors of anti-icing properties, potential techniques of superhydrophobic surfaces on transmission lines, and, finally, presents future development challenges and prospects of superhydrophobic surfaces in the anti-icing protection of overhead transmission lines.
- Open Access
Influence of Electrolyte Temperature on Morphology and Properties of Composite Anodic Film on Titanium Alloy Ti-10V-2Fe-3Al
In this study, we introduced a novel environmentally-friendly electrolyte consisting of polytetrafluoroethylene (PTFE) nanoparticles and malic acid solution to fabricate composite anodic film on Ti-10V-2Fe-3Al alloy at different electrolyte temperatures. The morphology revealed that the PTFE nanoparticles were successfully incorporated into composite anodic films and embedded preferentially in the pores and cracks. Their performances (wear, corrosion and hydrophobicity) were evaluated via electrochemical tests, ball on disc tests, and a contact angle (CA) meter. Compared to the substrate of titanium alloy Ti-10V-2Fe-3Al, the composite anodic films exhibited the low wear rates, high corrosion resistance and good hydrophobicity. However, the microstructure and morphology of the films were affected by the electrolyte temperature. As a result, their performances were changed greatly as a function of the temperature and the film fabricated at 20 °C exhibited better performances (CA = 131.95, icorr = 6.75 × 10−8 A·cm−2, friction coefficient = 0.14) than those at other electrolyte temperatures. In addition, the corresponding lubrication mechanism of the composite anodic films was discussed.
Open AccessInfluence of Electrolyte Temperature on Morphology and Properties of Composite Anodic Film on Titanium Alloy Ti-10V-2Fe-3Al
In this study, we introduced a novel environmentally-friendly electrolyte consisting of polytetrafluoroethylene (PTFE) nanoparticles and malic acid solution to fabricate composite anodic film on Ti-10V-2Fe-3Al alloy at different electrolyte temperatures. The morphology revealed that the PTFE nanoparticles were successfully incorporated into composite anodic films and embedded preferentially in the pores and cracks. Their performances (wear, corrosion and hydrophobicity) were evaluated via electrochemical tests, ball on disc tests, and a contact angle (CA) meter. Compared to the substrate of titanium alloy Ti-10V-2Fe-3Al, the composite anodic films exhibited the low wear rates, high corrosion resistance and good hydrophobicity. However, the microstructure and morphology of the films were affected by the electrolyte temperature. As a result, their performances were changed greatly as a function of the temperature and the film fabricated at 20 °C exhibited better performances (CA = 131.95, icorr = 6.75 × 10−8 A·cm−2, friction coefficient = 0.14) than those at other electrolyte temperatures. In addition, the corresponding lubrication mechanism of the composite anodic films was discussed.