Boyu Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Boyu Li has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Shuyan Pan
State Grid Electric Power Research Institute, Nanjing, JiangSu, China
2 shared publications- Zhiguo Hao
Xian Jiaotong University, Xian, China
2 shared publications Baohui Zhang
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
1 shared publicationJinzhao Deng
State Key Laboratory of Smart Grid Protection and Operation Control, Nanjing, China
1 shared publicationJunhui Xiong
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
1 shared publication- Simeng Li
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
1 shared publication
Latest Publications
- 3 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4103-4113
Response Characteristics of the Buchholz Relay and Novel Non-Electric-Parameter Protection Methods
In recent years, many accidents occurred worldwide owing to Buchholz relay maloperation and failure to act in time, which significantly compromised the security of power systems. To address this problem, an experiment based on a 25 MVA/110 kV oil-immersed power transformer setup was performed to characterize the response of a Buchholz relay; gas-generation faults of different severity inside the transformer's oil tank were simulated by controlling the pressure and volume of injected gas. The experimental results reveal that the gas accumulation relay has high sensitivity but insufficient speediness. Further, the oil surge relay is relatively fast but low in sensitivity, whose action threshold is affected by static pressure difference. Based on the different characteristics of non-electric parameters under internal and external faults, a digital non-electric parameter protection method, which exhibits good performance, is devised. The findings of this study can lay the foundation for optimizing the design and evaluation of the Buchholz relay, and for developing non-electric parameter protection devices.
- 3 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4103-4113
Response Characteristics of the Buchholz Relay and Novel Non-Electric-Parameter Protection Methods
In recent years, many accidents occurred worldwide owing to Buchholz relay maloperation and failure to act in time, which significantly compromised the security of power systems. To address this problem, an experiment based on a 25 MVA/110 kV oil-immersed power transformer setup was performed to characterize the response of a Buchholz relay; gas-generation faults of different severity inside the transformer's oil tank were simulated by controlling the pressure and volume of injected gas. The experimental results reveal that the gas accumulation relay has high sensitivity but insufficient speediness. Further, the oil surge relay is relatively fast but low in sensitivity, whose action threshold is affected by static pressure difference. Based on the different characteristics of non-electric parameters under internal and external faults, a digital non-electric parameter protection method, which exhibits good performance, is devised. The findings of this study can lay the foundation for optimizing the design and evaluation of the Buchholz relay, and for developing non-electric parameter protection devices.
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Developing Characteristics of Oil-immersed Transformer Internal Fault with Dignostic Method Using Convergence Patterns of Free Gas
Light gas protection only operates when gas within the transformer collection chamber reaches threshold volume. Such criterion failed to reflect transformer conditions accurately due to the lack of understanding for defect developing process and corresponding gas generation- convergence pattern, which has led to lower protection reliability and has caused several transformer explosions. To address current problem, an experimental tank with structure resembling that of a power transformer is set up, inside which the needle-plate oil-pressboard breakdown model is planted. Experimental results indicate that throughout fault development, voltage drops became more frequent until arcing occurs, so is HFCT signal; meanwhile gas generation rate increases through slight partial discharge, spark discharge and arcing stage, the collected gas volume corresponds with patterns above. The purpose of this study is to clarify the defect developing process and the gas generation-convergence pattern for oil-immersed transformer internal fault in guidance for a more reliable protection method.
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Developing Characteristics of Oil-immersed Transformer Internal Fault with Dignostic Method Using Convergence Patterns of Free Gas
Light gas protection only operates when gas within the transformer collection chamber reaches threshold volume. Such criterion failed to reflect transformer conditions accurately due to the lack of understanding for defect developing process and corresponding gas generation- convergence pattern, which has led to lower protection reliability and has caused several transformer explosions. To address current problem, an experimental tank with structure resembling that of a power transformer is set up, inside which the needle-plate oil-pressboard breakdown model is planted. Experimental results indicate that throughout fault development, voltage drops became more frequent until arcing occurs, so is HFCT signal; meanwhile gas generation rate increases through slight partial discharge, spark discharge and arcing stage, the collected gas volume corresponds with patterns above. The purpose of this study is to clarify the defect developing process and the gas generation-convergence pattern for oil-immersed transformer internal fault in guidance for a more reliable protection method.