DCDaniel Humaran Cozar

Daniel Humaran Cozar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniel Humaran Cozar has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Towards a New Standard: Prospective Validation of Ex Vivo Fusion Confocal Microscopy for Intraoperative Margin Assessment in Breast-Conserving Cancer Surgery

    by Daniel Humaran, Ana Castillo, Lidia Blay, Iciar Pascual, Karol Matute-Molina, Javiera Pérez-Anker, Susana Puig, Pedro L. Fernández, Joan F. Julián

    Background/Objectives: Accurate intraoperative margin assessment is essential for ensuring complete tumour excision in breast-conserving surgery, minimising local recurrence, and avoiding reoperations. Ex vivo fusion confocal microscopy (EVFCM) provides real-time, high-resolution imaging of fresh, unfixed tissues that closely resembles conventional histological imaging. This study aimed to validate the diagnostic performance and clinical feasibility of EVFCM for real-time intraoperative margin assessment during breast cancer surgery. Methods: A prospective observational diagnostic validation study was conducted using 144 breast tissue specimens. The samples were stained with acridine orange and fast green and scanned using a VivaScope 2500M-G4 system. Two breast pathologists independently evaluated the EVFCM images, blinded to the conventional histology results, which served as the reference standard. The diagnostic accuracy, sensitivity, specificity, and interobserver agreement were calculated using Cohen’s κ. Results: Interobserver agreement was almost perfect for neoplasia detection (97.3%, κ = 0.942) and tumour type classification (93.8%, κ = 0.883). The EVFCM achieved 93.7% sensitivity and specificity, with 94.0% accuracy for tumour detection (κ = 0.929, p < 0.001); 95.8% accuracy for tumour type classification (κ = 0.925, p < 0.001); and 95.1% accuracy for invasive subtype identification (κ = 0.907, p < 0.001). For margin assessment, EVFCM achieved 80% sensitivity, 100% specificity, and 99.3% accuracy (κ = 0.857, p < 0.001), whereas margin distance evaluation (p < 0.001). Conclusions: EVFCM enables rapid, high-resolution imaging of fresh breast tissue, facilitating real-time intraoperative margin evaluation with excellent diagnostic concordance and workflow efficiency. Its integration into surgical practice could reduce re-excisions, enhance oncological safety, and improve patient outcomes in breast-conserving surgeries.


  • Open Access

    Unveiling a Surgical Revolution: The Use of Conventional Histology versus Ex Vivo Fusion Confocal Microscopy in Breast Cancer Surgery

    by Daniel Humaran, Javiera Pérez-Anker, Pedro L. Fernández, Lidia Blay, Iciar Pascual, Eva Castellà, Laia Pérez, Susana Puig, Josep Malvehy, Joan F. Julián

    Ex vivo fusion confocal microscopy (EVFCM) enables the rapid examination of breast tissue and has the potential to reduce the surgical margins and the necessity for further surgeries. Traditional methods, such as frozen section analysis, are limited by the distortion of tissue and artefacts, leading to false negatives and the need for additional surgeries. This study on observational diagnostic accuracy evaluated the ability of EVFCM to detect breast cancer. A total of 36 breast tissue samples, comprising 20 non-neoplastic and 16 neoplastic cases, were analysed using EVFCM and compared to the results obtained from routine histopathology. A Mohs surgeon experienced in EVFCM (evaluator A) and two breast pathologists unfamiliar with EVFCM (evaluators B and C) performed blinded analyses. EVFCM showed high concordance with the histopathology and the detection of neoplasia, with significant kappa values (p < 0.001). Evaluator A achieved 100% sensitivity and specificity. Evaluators B and C achieved a sensitivity of >87%, a specificity of >94%, positive predictive values of >95%, and negative predictive values of 81% and 94%, respectively. EVFCM therefore offers a promising technique for the assessment of margins in breast-conserving surgery. Its widespread adoption could significantly reduce re-excisions, lower healthcare costs, and improve cosmetic and oncological outcomes.


  • Fusión hepatolienal, un hallazgo extremadamente infrecuente

    by Daniel Humaran Cozar, María Galofré Recasens, Oriol Busquets Carrera, Ana Torres Marí

  • Hepatosplenic fusion: an extremely rare finding

    by Daniel Humaran Cozar, María Galofré Recasens, Oriol Busquets Carrera, Ana Torres Marí

  • Ex-vivo fusion confocal microscopy for margin assessment in breast cancer surgery

    by Daniel Humaran Cozar, Javiera Pérez-Anker, Pedro Fernández Ruiz, Eva Castellà Fernández, Laia Pérez Roca, Lidia Blay Aulina, Iciar Pascual Miguel, Susana Puig Sardà, Josep Malvehy Guilera, Joan Francesc Julián Ibáñez