Yanbing Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanbing Liu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Fangzhou Xu
Qilu University of Technology (Shandong Academy of Sciences)
3 shared publications - Jiancai Leng
Qilu University of Technology (Shandong Academy of Sciences)
3 shared publications - Chao Feng
Qilu University of Technology (Shandong Academy of Sciences)
2 shared publications - Jianqun Zhu
International School for Optoelectronic Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, P. R. China
2 shared publications - Licai Gao
International School for Optoelectronic Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, P. R. China
2 shared publications - Tianzheng He
Qilu University of Technology, no.3501,daxue road,changqing district, Jinan, Shandong, 250353, CHINA
2 shared publications
Latest Publications
- 24 July 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (4) , 046028
Research on coding and decoding algorithm of binocular brain-controlled unmanned vehicle
Objective. With the rapid development of brain–computer interface (BCI) technology, steady-state visual evoked potential (SSVEP) has emerged as an effective method for high-efficiency information transmission. However, traditional single-frequency stimulation methods face limitations in command set scalability and visual comfort. Approach. To address these issues, we propose a novel binocular SSVEP stimulation paradigm for brain-controlled unmanned vehicles. (UV) This system uses a checkerboard and phase encoding for stimulus presentation, encoding a single target with two frequencies to expand the command set. The frequencies are set between 30–35 Hz to enhance visual comfort. By leveraging polarized light technology, each eye receives distinct frequencies, suppressing intermodulation components and reducing the stimulated area for each eye. We also introduce an improved filter bank dual-frequency task-discriminant component analysis (FBD-TDCA) algorithm. Main results. Experimental results show that, in a 15-command simulation, only six frequencies successfully encoded all commands, achieving comparable performance to traditional single-frequency paradigms. Furthermore, the FBD-TDCA algorithm outperformed existing methods such as filter bank task-related component analysis and filter bank canonical correlation analysis, achieving a classification accuracy of 89.27% ± 3.67 and an information translate rate of 163.87 ± 14.32 bits min−1, with statistical significance confirmed through paired t-tests. The system’s practical application was further demonstrated in an online 12-command UV control task. Participants achieved an average classification accuracy of 90.34% ± 8.75%, with most maintaining low path deviation rates during navigation tasks. Significance. The proposed binocular SSVEP stimulation paradigm and FBD-TDCA algorithm address the limitations of traditional methods, offering enhanced command set scalability, improved visual comfort, and superior performance, paving the way for more efficient and user-friendly BCI applications in real-world scenarios.
- 24 July 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (4) , 046028
Research on coding and decoding algorithm of binocular brain-controlled unmanned vehicle
Objective. With the rapid development of brain–computer interface (BCI) technology, steady-state visual evoked potential (SSVEP) has emerged as an effective method for high-efficiency information transmission. However, traditional single-frequency stimulation methods face limitations in command set scalability and visual comfort. Approach. To address these issues, we propose a novel binocular SSVEP stimulation paradigm for brain-controlled unmanned vehicles. (UV) This system uses a checkerboard and phase encoding for stimulus presentation, encoding a single target with two frequencies to expand the command set. The frequencies are set between 30–35 Hz to enhance visual comfort. By leveraging polarized light technology, each eye receives distinct frequencies, suppressing intermodulation components and reducing the stimulated area for each eye. We also introduce an improved filter bank dual-frequency task-discriminant component analysis (FBD-TDCA) algorithm. Main results. Experimental results show that, in a 15-command simulation, only six frequencies successfully encoded all commands, achieving comparable performance to traditional single-frequency paradigms. Furthermore, the FBD-TDCA algorithm outperformed existing methods such as filter bank task-related component analysis and filter bank canonical correlation analysis, achieving a classification accuracy of 89.27% ± 3.67 and an information translate rate of 163.87 ± 14.32 bits min−1, with statistical significance confirmed through paired t-tests. The system’s practical application was further demonstrated in an online 12-command UV control task. Participants achieved an average classification accuracy of 90.34% ± 8.75%, with most maintaining low path deviation rates during navigation tasks. Significance. The proposed binocular SSVEP stimulation paradigm and FBD-TDCA algorithm address the limitations of traditional methods, offering enhanced command set scalability, improved visual comfort, and superior performance, paving the way for more efficient and user-friendly BCI applications in real-world scenarios.
- 30 November 2023
- Published by World Scientific Pub Co Pte Ltd in International Journal of Neural Systems
- Vol. 34 (01) , 2350067
Multilevel Laser-Induced Pain Measurement with Wasserstein Generative Adversarial Network — Gradient Penalty Model
Pain is an experience of unpleasant sensations and emotions associated with actual or potential tissue damage. In the global context, billions of people are affected by pain disorders. There are particular challenges in the measurement and assessment of pain, and the commonly used pain measuring tools include traditional subjective scoring methods and biomarker-based measures. The main tools for biomarker-based analysis are electroencephalography (EEG), electrocardiography and functional magnetic resonance. The EEG-based quantitative pain measurements are of immense value in clinical pain management and can provide objective assessments of pain intensity. The assessment of pain is now primarily limited to the identification of the presence or absence of pain, with less research on multilevel pain. High power laser stimulation pain experimental paradigm and five pain level classification methods based on EEG data augmentation are presented. First, the EEG features are extracted using modified S-transform, and the time-frequency information of the features is retained. Based on the pain recognition effect, the 20–40[ ]Hz frequency band features are optimized. Afterwards the Wasserstein generative adversarial network with gradient penalty is used for feature data augmentation. It can be inferred from the good classification performance of features in the parietal region of the brain that the sensory function of the parietal lobe region is effectively activated during the occurrence of pain. By comparing the latest data augmentation methods and classification algorithms, the proposed method has significant advantages for the five-level pain dataset. This research provides new ways of thinking and research methods related to pain recognition, which is essential for the study of neural mechanisms and regulatory mechanisms of pain.
- 30 November 2023
- Published by World Scientific Pub Co Pte Ltd in International Journal of Neural Systems
- Vol. 34 (01) , 2350067
Multilevel Laser-Induced Pain Measurement with Wasserstein Generative Adversarial Network — Gradient Penalty Model
Pain is an experience of unpleasant sensations and emotions associated with actual or potential tissue damage. In the global context, billions of people are affected by pain disorders. There are particular challenges in the measurement and assessment of pain, and the commonly used pain measuring tools include traditional subjective scoring methods and biomarker-based measures. The main tools for biomarker-based analysis are electroencephalography (EEG), electrocardiography and functional magnetic resonance. The EEG-based quantitative pain measurements are of immense value in clinical pain management and can provide objective assessments of pain intensity. The assessment of pain is now primarily limited to the identification of the presence or absence of pain, with less research on multilevel pain. High power laser stimulation pain experimental paradigm and five pain level classification methods based on EEG data augmentation are presented. First, the EEG features are extracted using modified S-transform, and the time-frequency information of the features is retained. Based on the pain recognition effect, the 20–40[ ]Hz frequency band features are optimized. Afterwards the Wasserstein generative adversarial network with gradient penalty is used for feature data augmentation. It can be inferred from the good classification performance of features in the parietal region of the brain that the sensory function of the parietal lobe region is effectively activated during the occurrence of pain. By comparing the latest data augmentation methods and classification algorithms, the proposed method has significant advantages for the five-level pain dataset. This research provides new ways of thinking and research methods related to pain recognition, which is essential for the study of neural mechanisms and regulatory mechanisms of pain.
- 16 November 2023
- Published by World Scientific Pub Co Pte Ltd in International Journal of Neural Systems
- Vol. 33 (12) , 2350066
Self-Supervised EEG Representation Learning with Contrastive Predictive Coding for Post-Stroke Patients
Stroke patients are prone to fatigue during the EEG acquisition procedure, and experiments have high requirements on cognition and physical limitations of subjects. Therefore, how to learn effective feature representation is very important. Deep learning networks have been widely used in motor imagery (MI) based brain-computer interface (BCI). This paper proposes a contrast predictive coding (CPC) framework based on the modified s-transform (MST) to generate MST-CPC feature representations. MST is used to acquire the temporal-frequency feature to improve the decoding performance for MI task recognition. EEG2Image is used to convert multi-channel one-dimensional EEG into two-dimensional EEG topography. High-level feature representations are generated by CPC which consists of an encoder and autoregressive model. Finally, the effectiveness of generated features is verified by the k-means clustering algorithm. It can be found that our model generates features with high efficiency and a good clustering effect. After classification performance evaluation, the average classification accuracy of MI tasks is 89% based on 40 subjects. The proposed method can obtain effective feature representations and improve the performance of MI-BCI systems. By comparing several self-supervised methods on the public dataset, it can be concluded that the MST-CPC model has the highest average accuracy. This is a breakthrough in the combination of self-supervised learning and image processing of EEG signals. It is helpful to provide effective rehabilitation training for stroke patients to promote motor function recovery.
- 16 November 2023
- Published by World Scientific Pub Co Pte Ltd in International Journal of Neural Systems
- Vol. 33 (12) , 2350066
Self-Supervised EEG Representation Learning with Contrastive Predictive Coding for Post-Stroke Patients
Stroke patients are prone to fatigue during the EEG acquisition procedure, and experiments have high requirements on cognition and physical limitations of subjects. Therefore, how to learn effective feature representation is very important. Deep learning networks have been widely used in motor imagery (MI) based brain-computer interface (BCI). This paper proposes a contrast predictive coding (CPC) framework based on the modified s-transform (MST) to generate MST-CPC feature representations. MST is used to acquire the temporal-frequency feature to improve the decoding performance for MI task recognition. EEG2Image is used to convert multi-channel one-dimensional EEG into two-dimensional EEG topography. High-level feature representations are generated by CPC which consists of an encoder and autoregressive model. Finally, the effectiveness of generated features is verified by the k-means clustering algorithm. It can be found that our model generates features with high efficiency and a good clustering effect. After classification performance evaluation, the average classification accuracy of MI tasks is 89% based on 40 subjects. The proposed method can obtain effective feature representations and improve the performance of MI-BCI systems. By comparing several self-supervised methods on the public dataset, it can be concluded that the MST-CPC model has the highest average accuracy. This is a breakthrough in the combination of self-supervised learning and image processing of EEG signals. It is helpful to provide effective rehabilitation training for stroke patients to promote motor function recovery.