LLLinying Li

Linying Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Linying Li has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Harnessing Pharmacokinetic Modeling to Develop a Long-Acting Subcutaneous HIV Treatment Platform for Young Children

    by Daniel Oliveira, Daniela Cruz, Leanna P. K. Levin, Linying Li, Chasity A. Norton, Georgina Dobek, Xiaolei Wang, Ronald Veazey, Meagan Watkins, Amanda P. Schauer, et al.

    Background: Long-acting drug delivery strategies could augment pediatric human immunodeficiency virus (HIV) treatment effectiveness by bypassing population-specific challenges such as adherence. We harnessed pharmacokinetic (PK) modeling to develop a biodegradable, subcutaneous (SQ), reservoir-style implant for HIV treatment in 2–5-year-old children. Methods: Plasma was collected from New Zealand White rabbits over 30 h after a single intravenous (IV) bolus of bictegravir (BIC, 0.75 mg/kg), islatravir (ISL, 5 mg/kg) and/or emtricitabine (FTC, 30 mg/kg) then over a year after subcutaneous insertion of two to three implants eluting these antiretrovirals. Plasma antiretrovirals were quantified by HPLC-MS/MS and population PK models were fit to the IV PK profile to derive a mean unit impulse response (UIR). UIR was used to numerically deconvolve SQ absorption rate from the implant PK profile. SQ dosing rates were translated to pediatric plasma concentrations using published clinical PK parameters. Results: BIC, FTC, and ISL PK profiles were best described by two-compartment models. Each implant achieved quantifiable plasma concentrations for >360 days. Median SQ absorption rates (μg/day) at 3, 6 and 12 months of implantation were 116, 98 and 71 for BIC; 116, 37 and 5 for ISL; and 236, 116 and 24 for FTC. These 6-month dosing rates translated to pediatric plasma concentrations of 24 ng/mL BIC, 0.14 ng/mL ISL, and 0.7 ng/mL FTC. Conclusions: Our novel long-acting delivery platform exhibited antiretroviral SQ dosing rates for ≥6 months that are anticipated to achieve plasma concentrations in children within an efficacious range warranting further development for pediatric HIV treatment.


  • Open Access

    Pharmacokinetic Study of Islatravir and Etonogestrel Implants in Macaques

    by Michele B. Daly, Andres Wong-Sam, Linying Li, Archana Krovi, Gregory J. Gatto, Chasity Norton, Ellen H. Luecke, Victoria Mrotz, Catalina Forero, Mackenzie L. Cottrell, et al.

    The prevention of HIV and unintended pregnancies is a public health priority. Multi-purpose prevention technologies capable of long-acting HIV and pregnancy prevention are desirable for women. Here, we utilized a preclinical macaque model to evaluate the pharmacokinetics of biodegradable ε-polycaprolactone implants delivering the antiretroviral islatravir (ISL) and the contraceptive etonogestrel (ENG). Three implants were tested: ISL-62 mg, ISL-98 mg, and ENG-33 mg. Animals received one or two ISL-eluting implants, with doses of 42, 66, or 108 µg of ISL/day with or without an additional ENG-33 mg implant (31 µg/day). Drug release increased linearly with dose with median [range] plasma ISL levels of 1.3 [1.0–2.5], 1.9 [1.2–6.3] and 2.8 [2.3–11.6], respectively. The ISL-62 and 98 mg implants demonstrated stable drug release over three months with ISL-triphosphate (ISL-TP) concentr54ations in PBMCs above levels predicted to be efficacious for PrEP. Similarly, ENG implants demonstrated sustained drug release with median [range] plasma ENG levels of 495 [229–1110] pg/mL, which suppressed progesterone within two weeks and showed no evidence of altering ISL pharmacokinetics. Two of the six ISL-98 mg implants broke during the study and induced implant-site reactions, whereas no reactions were observed with intact implants. We show that ISL and ENG biodegradable implants are safe and yield sufficient drug levels to achieve prevention targets. The evaluation of optimized implants with increased mechanical robustness is underway for improved durability and vaginal efficacy in a SHIV challenge model.