Wang Ma
Wang Ma has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Guanqun Sun
State Grid Hubei Electric Power Research Institute, Wuhan 430077, China
2 shared publications - Yikai Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China
2 shared publications - Binxin Yin
State Grid Hubei Electric Power Research Institute, Wuhan 430077, China
1 shared publication - Chaozheng Xu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China
1 shared publication - Defu Cai
State Grid Hubei Electric Power Research Institute, Wuhan 430064, China
1 shared publication - Dian Xu
State Grid Hubei Electric Power Research Institute, Wuhan 430077, China
1 shared publication
Latest Publications
- Open Access
- 19 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4814
A Novel Method for Dynamic Load Restoration of Transmission Networks After Faults with Large-Scale Renewable Energy Integration
The large-scale integration of renewable energy sources introduces significant temporal variability into power systems, rendering traditional static network reconfiguration methods inadequate for post-fault load restoration in transmission networks. To address this challenge, a novel dynamic restoration method is proposed that explicitly accounts for uncertainty in renewable energy. Wind and photovoltaic output uncertainties are modeled using Weibull and Beta distributions, respectively. Typical operating scenarios are generated via Latin hypercube sampling combined with an improved K-means clustering algorithm, while the node contraction method is employed to quantify the topological importance of load buses. A multi-period optimization model is formulated to maximize weighted load restoration and minimize line switching costs, subject to comprehensive constraints including network topology, AC power flow, and short-circuit current limits. This mixed-integer nonlinear problem is solved using a GA-PSO parallel hybrid algorithm. Simulation results on the modified IEEE 39-bus system under four typical renewable energy scenarios show that the proposed method can generate scenario-specific restoration schemes and that cross-scenario feasibility verification is necessary when the source-load imbalance is severe.
- 19 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4814
Open AccessA Novel Method for Dynamic Load Restoration of Transmission Networks After Faults with Large-Scale Renewable Energy Integration
The large-scale integration of renewable energy sources introduces significant temporal variability into power systems, rendering traditional static network reconfiguration methods inadequate for post-fault load restoration in transmission networks. To address this challenge, a novel dynamic restoration method is proposed that explicitly accounts for uncertainty in renewable energy. Wind and photovoltaic output uncertainties are modeled using Weibull and Beta distributions, respectively. Typical operating scenarios are generated via Latin hypercube sampling combined with an improved K-means clustering algorithm, while the node contraction method is employed to quantify the topological importance of load buses. A multi-period optimization model is formulated to maximize weighted load restoration and minimize line switching costs, subject to comprehensive constraints including network topology, AC power flow, and short-circuit current limits. This mixed-integer nonlinear problem is solved using a GA-PSO parallel hybrid algorithm. Simulation results on the modified IEEE 39-bus system under four typical renewable energy scenarios show that the proposed method can generate scenario-specific restoration schemes and that cross-scenario feasibility verification is necessary when the source-load imbalance is severe.
- Open Access
- 26 November 2023
- Published by MDPI AG in Electronics
- Vol. 12 (23) , 4790
A Fault Location Method for Medium Voltage Distribution Network Based on Ground Fault Transfer Device
The arc suppression device based on ground fault transfer (GFT) has been preliminarily applied in the medium voltage distribution network (MVDN). An accurate travelling wave (TW) fault location method is proposed to extend the use of the ground fault transfer device. D-PMU is used as a travelling wave detection tool to record the transient voltage travelling waves of fault grounding and bus active grounding during arc suppression. Then, the faulty section is identified through the time difference of travelling wave arrival at the upstream and downstream measurement points. On this basis, the fault location equations of the arrival time and distance of the upstream travelling wave are established, and an accurate fault location method based on the arrival time difference of the travelling wave is proposed. The simulation model is established by PSCAD/EMTDC, and the results show that the method has high location accuracy, and the absolute error is less than 30 m. It is not affected by the TW velocity, the fault conditions, or the distributed power sources.
- 26 November 2023
- Published by MDPI AG in Electronics
- Vol. 12 (23) , 4790
Open AccessA Fault Location Method for Medium Voltage Distribution Network Based on Ground Fault Transfer Device
The arc suppression device based on ground fault transfer (GFT) has been preliminarily applied in the medium voltage distribution network (MVDN). An accurate travelling wave (TW) fault location method is proposed to extend the use of the ground fault transfer device. D-PMU is used as a travelling wave detection tool to record the transient voltage travelling waves of fault grounding and bus active grounding during arc suppression. Then, the faulty section is identified through the time difference of travelling wave arrival at the upstream and downstream measurement points. On this basis, the fault location equations of the arrival time and distance of the upstream travelling wave are established, and an accurate fault location method based on the arrival time difference of the travelling wave is proposed. The simulation model is established by PSCAD/EMTDC, and the results show that the method has high location accuracy, and the absolute error is less than 30 m. It is not affected by the TW velocity, the fault conditions, or the distributed power sources.