Jun Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jun Feng has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Lei Tian
Beijing Tongren Hospital, Capital Medical University
3 shared publications - Ying Jie
Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing 100730, China
3 shared publications - Ao Li
Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing 100730, China
2 shared publications - Yiran M.S. Hao
Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, Beijing, China
2 shared publications - Guang-Quan Zhou
School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
1 shared publication - Hao Guo
School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
1 shared publication
Latest Publications
- Open Access
- 5 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2856
Benchmarking Statistical, Machine Learning, and Exploratory Deep Learning Models for the Short-Term Forecasting of Monthly Aggregated Adult Ocular Surface Indicators: An Exploratory Hospital-Level Study
Background/Objectives: First NIBUT, Average NIBUT, and tear meniscus height (TMH) are routinely used to characterize tear film stability and tear volume at individual visits, whereas their longitudinal behavior across the hospital-attending population is less well characterized. Aggregating routine examinations over time may provide a continuous hospital-level view of ocular surface status and enable the short-term forecasting of expected trajectories. We therefore evaluated a benchmark-first framework for monthly aggregated adult ocular surface indicators. Methods: This retrospective time-series study used de-identified adult eye-level Keratograph 5M records from July 2018 to November 2023. After cleaning, 31,492 records from 13,749 patients and 15,334 examination occasions were aggregated across 65 calendar months (64 observed months; March 2020 had no eligible records). Seven benchmark models and two exploratory deep learning comparators were evaluated using eight rolling-origin 3-month test windows. Results: Linear trend had the lowest mean origin-level macro-normalized RMSE (0.875; 95% bootstrap CI, 0.497–1.421), followed by simple exponential smoothing (0.907) and SARIMA(1,0,0)(1,0,0,12) (0.940). The paired difference between linear trend and simple exponential smoothing was small and did not show clear superiority (mean difference, −0.032; 95% bootstrap CI, −0.217 to 0.135; p = 0.789). The model with the lowest pooled error differed by target, while patient-month and sample-size-weighted sensitivity analyses gave a similar overall benchmark pattern. The exploratory LSTM and Transformer did not show a consistent advantage over the leading simple models. Conclusions: In this short hospital-level monthly series, simple forecasting models remained competitive, while no single model showed consistent superiority across forecast origins and sensitivity analyses. By extending ocular surface assessment from isolated examinations to longitudinal hospital-level trajectories, this framework provides a methodological basis for monitoring temporal changes in tear film stability and tear volume and for future quality monitoring, clinical, and epidemiological applications.
- 5 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2856
Open AccessBenchmarking Statistical, Machine Learning, and Exploratory Deep Learning Models for the Short-Term Forecasting of Monthly Aggregated Adult Ocular Surface Indicators: An Exploratory Hospital-Level Study
Background/Objectives: First NIBUT, Average NIBUT, and tear meniscus height (TMH) are routinely used to characterize tear film stability and tear volume at individual visits, whereas their longitudinal behavior across the hospital-attending population is less well characterized. Aggregating routine examinations over time may provide a continuous hospital-level view of ocular surface status and enable the short-term forecasting of expected trajectories. We therefore evaluated a benchmark-first framework for monthly aggregated adult ocular surface indicators. Methods: This retrospective time-series study used de-identified adult eye-level Keratograph 5M records from July 2018 to November 2023. After cleaning, 31,492 records from 13,749 patients and 15,334 examination occasions were aggregated across 65 calendar months (64 observed months; March 2020 had no eligible records). Seven benchmark models and two exploratory deep learning comparators were evaluated using eight rolling-origin 3-month test windows. Results: Linear trend had the lowest mean origin-level macro-normalized RMSE (0.875; 95% bootstrap CI, 0.497–1.421), followed by simple exponential smoothing (0.907) and SARIMA(1,0,0)(1,0,0,12) (0.940). The paired difference between linear trend and simple exponential smoothing was small and did not show clear superiority (mean difference, −0.032; 95% bootstrap CI, −0.217 to 0.135; p = 0.789). The model with the lowest pooled error differed by target, while patient-month and sample-size-weighted sensitivity analyses gave a similar overall benchmark pattern. The exploratory LSTM and Transformer did not show a consistent advantage over the leading simple models. Conclusions: In this short hospital-level monthly series, simple forecasting models remained competitive, while no single model showed consistent superiority across forecast origins and sensitivity analyses. By extending ocular surface assessment from isolated examinations to longitudinal hospital-level trajectories, this framework provides a methodological basis for monitoring temporal changes in tear film stability and tear volume and for future quality monitoring, clinical, and epidemiological applications.
- Open Access
- 6 June 2025
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 51 (9) , 375-379
Influence of Overnight Orthokeratology on Ocular Surface and Blink Patterns in Children and Adolescents—A Prospective Cohort Study
Objectives: To investigate the effect of overnight orthokeratology (OOK) on ocular surface and blinking patterns in children and adolescents. Methods: A prospective cohort study was conducted including 27 eyes of 27 children from Beijing Tongren Hospital who received OOK correction and 31 eyes of 31 spectacle wearing children. Tests were performed before and at 3 and 6 months after OOK wear. Ocular surface assessment included tear meniscus height, noninvasive tear breakup time, lipid layer thickness, number of incomplete blinks, number of total blinks, and fluorescein tear breakup time. Results: Before treatment, there were no statistically significant differences in various indicators between the two groups. After wearing OOK for 3 months and 6 months, there were no significant differences between the tear meniscus height, noninvasive tear breakup time, lipid layer thickness, number of incomplete and total blinks, fluorescein tear breakup time groups, and upper and lower lid meibomian gland atrophy rate (P>0.05). However, the corneal fluorescein staining scores in the OOK group were significantly higher than those in the spectacle group (P<0.001). Conclusions: Short-term use of OOK in children and adolescents has a relatively minor impact on ocular surfaces and is considered relatively safe to use. However, it significantly increases corneal fluorescein staining scores, which may suggest the presence of corneal epithelial damage.
- 6 June 2025
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 51 (9) , 375-379
Open AccessInfluence of Overnight Orthokeratology on Ocular Surface and Blink Patterns in Children and Adolescents—A Prospective Cohort Study
Objectives: To investigate the effect of overnight orthokeratology (OOK) on ocular surface and blinking patterns in children and adolescents. Methods: A prospective cohort study was conducted including 27 eyes of 27 children from Beijing Tongren Hospital who received OOK correction and 31 eyes of 31 spectacle wearing children. Tests were performed before and at 3 and 6 months after OOK wear. Ocular surface assessment included tear meniscus height, noninvasive tear breakup time, lipid layer thickness, number of incomplete blinks, number of total blinks, and fluorescein tear breakup time. Results: Before treatment, there were no statistically significant differences in various indicators between the two groups. After wearing OOK for 3 months and 6 months, there were no significant differences between the tear meniscus height, noninvasive tear breakup time, lipid layer thickness, number of incomplete and total blinks, fluorescein tear breakup time groups, and upper and lower lid meibomian gland atrophy rate (P>0.05). However, the corneal fluorescein staining scores in the OOK group were significantly higher than those in the spectacle group (P<0.001). Conclusions: Short-term use of OOK in children and adolescents has a relatively minor impact on ocular surfaces and is considered relatively safe to use. However, it significantly increases corneal fluorescein staining scores, which may suggest the presence of corneal epithelial damage.
- Open Access
- 26 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (23) , 3533
An Automated Grading System Based on Topological Features for the Evaluation of Corneal Fluorescein Staining in Dry Eye Disease
Background: Corneal fluorescein staining is a key biomarker in evaluating dry eye disease. However, subjective scales of corneal fluorescein staining are lacking in consistency and increase the difficulties of an accurate diagnosis for clinicians. This study aimed to propose an automatic machine learning-based method for corneal fluorescein staining evaluation by utilizing prior information about the spatial connection and distribution of the staining region. Methods: We proposed an end-to-end automatic machine learning-based classification model that consists of staining region identification, feature signature construction, and machine learning-based classification, which fully scrutinizes the multiscale topological features together with conventional texture and morphological features. The proposed model was evaluated using retrospective data from Beijing Tongren Hospital. Two masked ophthalmologists scored images independently using the Sjögren’s International Collaborative Clinical Alliance Ocular Staining Score scale. Results: A total of 382 images were enrolled in the study. A signature with six topological features, two textural features, and two morphological features was constructed after feature extraction and selection. Support vector machines showed the best classification performance (accuracy: 82.67%, area under the curve: 96.59%) with the designed signature. Meanwhile, topological features contributed more to the classification, compared with other features. According to the distribution and correlation with features and scores, topological features performed better than others. Conclusions: An automatic machine learning-based method was advanced for corneal fluorescein staining evaluation. The topological features in presenting the spatial connectivity and distribution of staining regions are essential for an efficient corneal fluorescein staining evaluation. This result implies the clinical application of topological features in dry-eye diagnosis and therapeutic effect evaluation.
- 26 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (23) , 3533
Open AccessAn Automated Grading System Based on Topological Features for the Evaluation of Corneal Fluorescein Staining in Dry Eye Disease
Background: Corneal fluorescein staining is a key biomarker in evaluating dry eye disease. However, subjective scales of corneal fluorescein staining are lacking in consistency and increase the difficulties of an accurate diagnosis for clinicians. This study aimed to propose an automatic machine learning-based method for corneal fluorescein staining evaluation by utilizing prior information about the spatial connection and distribution of the staining region. Methods: We proposed an end-to-end automatic machine learning-based classification model that consists of staining region identification, feature signature construction, and machine learning-based classification, which fully scrutinizes the multiscale topological features together with conventional texture and morphological features. The proposed model was evaluated using retrospective data from Beijing Tongren Hospital. Two masked ophthalmologists scored images independently using the Sjögren’s International Collaborative Clinical Alliance Ocular Staining Score scale. Results: A total of 382 images were enrolled in the study. A signature with six topological features, two textural features, and two morphological features was constructed after feature extraction and selection. Support vector machines showed the best classification performance (accuracy: 82.67%, area under the curve: 96.59%) with the designed signature. Meanwhile, topological features contributed more to the classification, compared with other features. According to the distribution and correlation with features and scores, topological features performed better than others. Conclusions: An automatic machine learning-based method was advanced for corneal fluorescein staining evaluation. The topological features in presenting the spatial connectivity and distribution of staining regions are essential for an efficient corneal fluorescein staining evaluation. This result implies the clinical application of topological features in dry-eye diagnosis and therapeutic effect evaluation.