Jin-Ho Youn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jin-Ho Youn has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Dae-Kyung Kwak
Department of Orthopedic Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, Korea
1 shared publication - Dong-Young Je
Department of Biomedical Engineering, College of Biomedical Science & Engineering, Inje University, Gimhae-si 50834, Republic of Korea
1 shared publication - Hyun-Soo Moon
Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
1 shared publication - Je-Hyun Yoo
Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14068, Republic of Korea
1 shared publication - Jeong-Woo Lee
Department of Biomedical Engineering, College of Biomedical Science & Engineering, Inje University, Gimhae-si 50834, Republic of Korea
1 shared publication - Jin-Woo Ahn
Dept. of Mechatronics Engineering, Kyungsung University, Busan, Korea
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (4) , 622-630
Optimal Plate Position for Biomechanical Stability in Medial Opening-Wedge High Tibial Osteotomy: A Finite Element Analysis
Moon HS, et al. Clin Orthop Surg. 2025 Aug;17(4):622-630. https://doi.org/10.4055/cios24431
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (4) , 622-630
Open AccessOptimal Plate Position for Biomechanical Stability in Medial Opening-Wedge High Tibial Osteotomy: A Finite Element Analysis
Moon HS, et al. Clin Orthop Surg. 2025 Aug;17(4):622-630. https://doi.org/10.4055/cios24431
- Open Access
- 27 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (12) , 1365
Validation of the Finite Element Model versus Biomechanical Assessments of Dental Implants and Total Knee Replacements
Computer modeling and simulation (CM&S) technology is widely used in the medical device industry due to its advantages such as reducing testing time and costs. However, the developer’s parameter settings during the modeling and simulation process can have a significant impact on the results. This study developed a test model for the rotational shear strength of dental implants and the constraint force of total knee replacements based on CM&S technology and proposes ideal parameters to ensure reliability. For dental implants, the load area and sliding contact conditions were considered, and for total knee replacements, the friction coefficient, medial–lateral displacement, valgus–varus rotation, and elastic modulus were considered. By comparing the simulation results and mechanical tests, boundary conditions with an error rate of less than 1.5% were selected. When a jig (gripper and collector) was applied with the same boundary conditions, an error rate of 48~22% occurred; otherwise, it was confirmed that the error rate was within 10~0.2%. The FE model was verified with an error of 2.49 to 3% compared to the mechanical test. The friction coefficient variable had the greatest influence on the results, accounting for 10 to 13%, and it was confirmed that valgus–varus rotation had a greater influence on the results than medial–lateral displacement. Relatively, the elastic modulus of the insert had the least effect on the results. These research results are expected to make CM&S techniques useful as a medical device digital development tool (M3DT) in the development of total knee replacements and dental implants.
- 27 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (12) , 1365
Open AccessValidation of the Finite Element Model versus Biomechanical Assessments of Dental Implants and Total Knee Replacements
Computer modeling and simulation (CM&S) technology is widely used in the medical device industry due to its advantages such as reducing testing time and costs. However, the developer’s parameter settings during the modeling and simulation process can have a significant impact on the results. This study developed a test model for the rotational shear strength of dental implants and the constraint force of total knee replacements based on CM&S technology and proposes ideal parameters to ensure reliability. For dental implants, the load area and sliding contact conditions were considered, and for total knee replacements, the friction coefficient, medial–lateral displacement, valgus–varus rotation, and elastic modulus were considered. By comparing the simulation results and mechanical tests, boundary conditions with an error rate of less than 1.5% were selected. When a jig (gripper and collector) was applied with the same boundary conditions, an error rate of 48~22% occurred; otherwise, it was confirmed that the error rate was within 10~0.2%. The FE model was verified with an error of 2.49 to 3% compared to the mechanical test. The friction coefficient variable had the greatest influence on the results, accounting for 10 to 13%, and it was confirmed that valgus–varus rotation had a greater influence on the results than medial–lateral displacement. Relatively, the elastic modulus of the insert had the least effect on the results. These research results are expected to make CM&S techniques useful as a medical device digital development tool (M3DT) in the development of total knee replacements and dental implants.