Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dimitrios Spagopoulos has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Compression Moulding Technique: A Silicone-Guided Modification of the Injection Moulding Workflow for Direct Composite Restorations

    by Dimitrios Spagopoulos, Ioulianos Rachiotis, Christos Rahiotis

    Background/Objectives: Injection moulding has become a predictable technique for transferring a diagnostic wax-up to direct composite restorations. However, conventional workflows that rely exclusively on injectable flowable composites may have limitations in material handling, mechanical performance, and the dimensional stability of the transparent silicone index. The purpose of this technical note was to describe a silicone-guided modification of the injection moulding workflow, referred to as the compression moulding technique, and to illustrate its clinical application in three representative cases. Methods: The proposed workflow combines a dual-layer silicone index consisting of a transparent polyvinyl siloxane material supported by a high-hardness bite-registration silicone with a preheated medium-viscosity resin composite. Following digital planning and diagnostic wax-up, the composite is positioned within the silicone index and adapted to the prepared tooth surfaces by controlled compression. Three clinical cases with different restorative indications were included to demonstrate the technique’s versatility. Results: In all three cases, the proposed workflow enabled accurate transfer of the diagnostic wax-up while providing improved stabilization of the transparent silicone index during composite placement. The combination of controlled compression, a rigid supporting silicone, and preheated paste composite facilitated material adaptation, minimized manual sculpting, and produced predictable esthetic outcomes in a minimally invasive chairside procedure. Conclusions: The compression moulding technique represents a practical modification of the conventional injection moulding workflow for direct composite restorations. The proposed protocol may improve index stability, material handling, and clinical versatility while maintaining the advantages of silicone-guided restorative procedures. Because the present article is intended to describe a technical workflow supported by representative clinical cases, further prospective clinical studies with long-term follow-up are required before conclusions regarding clinical superiority or long-term performance can be drawn.

  • Open Access

    Perceived Diagnostic Value of Fluorescence-Enhanced 3D Imaging for Detecting Caries Adjacent to Restorations: A Questionnaire-Based Study

    by Dimitrios Spagopoulos, Grigoria Gkavela, Christos Rahiotis

    Background/Objectives: Caries adjacent to restorations remain a leading cause of restoration failure and replacement. Conventional diagnostic methods are limited by subjectivity and restricted visualization. Fluorescence-enhanced three-dimensional (3D) imaging has been proposed to improve detection accuracy, but evidence on its clinical perception and usability remains scarce. The objective of this study was to evaluate the perceived diagnostic value of fluorescence-enhanced 3D imaging in detecting caries adjacent to direct restorations. Methods: A cross-sectional questionnaire-based survey was distributed to undergraduate dental students and licensed dentists (n = 94). Participants assessed images of extracted teeth with direct restorations presented in three formats: conventional photographs, monochromatic 3D models, and 3D models with fluorescence. Responses were analyzed using descriptive statistics, chi-square tests, and Cohen’s kappa to measure inter-rater agreement. Results: Overall, 64.9% of respondents reported that fluorescence-enhanced images improved their diagnostic decision-making, while 29.8% reported partial benefit. Fluorescence was mainly perceived as helpful in defining cavity margins (53.3%) and assessing lesion volume (42.4%). Most participants preferred 3D models with fluorescence over conventional images for diagnostic value. However, inter-rater agreement was generally poor (κ range: –0.05 to 0.25; median κ = 0.02; only 4 images showed weak but statistically significant agreement), with only a few images demonstrating weak but statistically significant agreement. Notably, 39.3% of participants reported prior experience with 3D imaging, which was associated with greater confidence in interpreting fluorescence-enhanced images. Participants with prior 3D imaging experience reported greater confidence in fluorescence interpretation. Conclusions: While fluorescence-enhanced 3D imaging is perceived as a useful adjunct for visualizing lesion margins and depth, it does not currently yield consistent diagnostic agreement across clinicians. Training, calibration, and integration of artificial intelligence support may enhance the clinical reliability of this technology.

  • Open Access

    Fluorescence and Near-Infrared Light for Detection of Secondary Caries: A Systematic Review

    by Dimitrios Spagopoulos, Stavroula Michou, Sotiria Gizani, Eftychia Pappa, Christos Rahiotis

    Background: Early detection of secondary caries near dental restorations is essential to prevent further complications. This systematic review seeks to evaluate the sensitivity of fluorescence and near-infrared (NIR) imaging techniques for detecting secondary caries and to provide insight into their clinical utility. Methods: A comprehensive search strategy was used to select studies from seven databases, emphasizing diagnostic accuracy studies of secondary caries detection using fluorescence and NIR imaging techniques. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) instrument assessed bias risk and practicality. Two evaluators performed data extraction, screening, and quality assessment independently. Results: From 3110 initial recordings, nine studies were selected for full-text analysis. Wide variations in sensitivity (SE) and specificity (SP) values were reported across the studies. These studies exhibited variable SE and SP values, and the findings highlighted the importance of method selection based on clinical context. This systematic review underlines the potential for fluorescence and NIR imaging to detect secondary caries. However, results from different studies vary, indicating the need to consider additional variables such as restoration materials. Conclusions: Although these technologies exhibit potential for detecting caries, our research underscores the complex procedure of identifying secondary caries lesions. It is a continuous necessity for progress in dental diagnostics to promptly identify secondary caries lesions, particularly those in proximity to tooth-colored ones.


  • Open Access

    In Vitro Trueness and Precision of Intraoral Scanners in a Four-Implant Complete-Arch Model

    by Dimitrios Spagopoulos, George Kaisarlis, Foteini Spagopoulou, Demetrios J. Halazonetis, Jan-Frederik Güth, Efstratios Papazoglou

    (1) Background: New intraoral (IOS) and laboratory scanners appear in the market and their trueness and precision have not been compared. (2) Methods: Seven IOS and two laboratory scanners were used to scan a mandibular edentulous model with four parallel internal hexagon implant analogues and PEEK scan bodies. Digital models in Standard Tessellation Language (STL) were created. The master model with the scan bodies was scanned (×10) with a computerized numerical control 3D Coordinate Measuring Machine (CMM). The short (distances of adjacent scan posts) and long distances (distances of the scan posts with non-adjacent sites in the arch) among the centroids of the four analogues were calculated using CMM special software. Trueness (comparisons with the master model) and precision (intragroup comparisons) were statistically compared with ANOVA, chi-square and Tukey tests. (3) Results: Laboratory scanners had the best trueness and precision compared to all IOSs for long distances. Only iTero (Align Technologies Inc., Milpitas, CA, USA) had comparable trueness with one laboratory scanner in short and long distances. For short distances, CS3600 (Carestream Health, Inc., Rochester, NY, USA), Omnicam, Primescan (Sirona Dental Sys-tems GmbH, Bens-heim, Germany) and TRIOS 4 (3Shape A/S, Copen-hagen, Denmark) had similar trueness to one laboratory scanner. From those, only Omnicam and Primescan had similar precision as the same laboratory scanner. Most IOSs seem to work better for smaller distances and are less precise in cross-arch distances. (4) Conclusions: The laboratory scanners showed significantly higher trueness and precision than all IOSs tested for the long-distance group; for the short distance, some IOSs were not different in trueness and precision than the laboratory scanners.