Jayaprakash Ponnaiyan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jayaprakash Ponnaiyan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Faridah Hussain
SIRIM Standards Technology Sdn. Bhd., Seksyen 15, 40200 Shah Alam, Selangor, Malaysia
2 shared publications - Mohd Afzanizam Mohd Rosli
Faculty of Mechanical Technology and Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka, Malaysia
2 shared publications - Nurfarhana Salimen
Faculty of Mechanical Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka, Malaysia
2 shared publications - Safarudin Gazali Herawan
Industrial Engineering Department, Faculty of Engineering, Bina Nusantara University, Jakarta 11480, Indonesia
2 shared publications - Azrin Hani Abdul Rashid
Faculty of Engineering Technology, Universiti Tun Hussein Onn Malaysia, Johor 86400, Malaysia
1 shared publication Chia Zhi Horng
Faculty of Mechanical Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka, Malaysia
1 shared publication
Latest Publications
- Open Access
- 20 February 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 127 (2) , 249-261
Latent Heat Validation of Phase Change Material using T-History Method
Phase change material (PCM) is a material that will absorb and release heat over a specified timeframe and it functions as a cooling technique to reduce temperature of the photovoltaic panels. The T-history method is a technique used to measure the thermal diffusivity of a material by subjecting a sample to a sudden temperature change. This project proposed PCM36 as a cooling method for PV temperature reduction and the expected result for this study is to meet the data from manufacturer with a small different percentage. T-history is introduced to validate the PCM36 latent heat capacity and melting point and thus compare it with the manufacturer data. The manufacturer data's latent heat capacity and melting point are 220 J/g and 36 ˚C, respectively. Based on the result obtained, the latent heat capacity from T-history is 217.891 J/g and is 0.9591% different compared with the manufacturer data. On the other hand, the melting point based on the T-history curve is in the range of 36 ˚C-38 ˚C, which is similar to the manufacturer data.
- 20 February 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 127 (2) , 249-261
Open AccessLatent Heat Validation of Phase Change Material using T-History Method
Phase change material (PCM) is a material that will absorb and release heat over a specified timeframe and it functions as a cooling technique to reduce temperature of the photovoltaic panels. The T-history method is a technique used to measure the thermal diffusivity of a material by subjecting a sample to a sudden temperature change. This project proposed PCM36 as a cooling method for PV temperature reduction and the expected result for this study is to meet the data from manufacturer with a small different percentage. T-history is introduced to validate the PCM36 latent heat capacity and melting point and thus compare it with the manufacturer data. The manufacturer data's latent heat capacity and melting point are 220 J/g and 36 ˚C, respectively. Based on the result obtained, the latent heat capacity from T-history is 217.891 J/g and is 0.9591% different compared with the manufacturer data. On the other hand, the melting point based on the T-history curve is in the range of 36 ˚C-38 ˚C, which is similar to the manufacturer data.
- Open Access
- 2 November 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 109 (2) , 168-183
The Performance Evaluation of Photovoltaic Integrated Organic Phase Change Material in a Single Container using Indoor Solar Simulator
Photovoltaic panels convert sunlight, a renewable energy source, into electrical energy. The abundant irradiance will heat the photovoltaic panel, reducing the panel's efficiency. This study proposes using PCM 36 as a cooling technique to reduce the temperature of the photovoltaic panel, which is low-cost and has higher latent heat capacity. The indoor solar simulator study is performed to meet the IEC 60904-9 standard. The research process starts with validating PCM 36, sun simulator testing, validating the photovoltaic panel, and fabricating a container to place the PCM 36 at the rear side of the photovoltaic panel to cool down the temperature. The final experiments are conducted indoors, using three different irradiance levels and a one-hour photovoltaic panel operation under the sun simulator. The optimal results reveal a 31.67% reduction in temperature and a 6.83% increase in electrical efficiency at a maximum of 40 minutes, 500 W/m2 irradiance, with a 9 mm thickness of PCM 36. Throughout this study, the efficiency of the photovoltaic system is enhanced by effectively reducing the temperature within the optimal range by incorporating phase change material.
- 2 November 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 109 (2) , 168-183
Open AccessThe Performance Evaluation of Photovoltaic Integrated Organic Phase Change Material in a Single Container using Indoor Solar Simulator
Photovoltaic panels convert sunlight, a renewable energy source, into electrical energy. The abundant irradiance will heat the photovoltaic panel, reducing the panel's efficiency. This study proposes using PCM 36 as a cooling technique to reduce the temperature of the photovoltaic panel, which is low-cost and has higher latent heat capacity. The indoor solar simulator study is performed to meet the IEC 60904-9 standard. The research process starts with validating PCM 36, sun simulator testing, validating the photovoltaic panel, and fabricating a container to place the PCM 36 at the rear side of the photovoltaic panel to cool down the temperature. The final experiments are conducted indoors, using three different irradiance levels and a one-hour photovoltaic panel operation under the sun simulator. The optimal results reveal a 31.67% reduction in temperature and a 6.83% increase in electrical efficiency at a maximum of 40 minutes, 500 W/m2 irradiance, with a 9 mm thickness of PCM 36. Throughout this study, the efficiency of the photovoltaic system is enhanced by effectively reducing the temperature within the optimal range by incorporating phase change material.