Chunhui Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chunhui Gao has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Guifang Qiao
School of Automation, Nanjing Institute of Technology, Nanjing 210096, China
2 shared publications - Hongfu Zuo
Civil Aviation Key Laboratory of Aircraft Health Monitoring and Intelligent Maintenance, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
2 shared publications - Tiewu Xiang
College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
2 shared publications - Baoan Du
School of Automation, Nanjing Institute of Technology, Nanjing 210096, China
1 shared publication - Xinyi Jiang
School of Automation, Nanjing Institute of Technology, Nanjing 210096, China
1 shared publication
Latest Publications
- Open Access
Pose Selection Based on a Hybrid Observation Index for Robotic Accuracy Improvement
The problem of the insufficient accuracy performance of industrial robots in high-precision manufacturing is addressed in this paper. Firstly, a kinematic error model based on an M-DH model was presented. Secondly, a hybrid observability index O6 was proposed to select the optimal poses for parameter identification. O6 is the combination of O1 and O3. The optimal poses were obtained by using the IOOPS algorithm. Thirdly, the fitness function for parameter identification was established, and the Levenberg–Marquardt (LM) algorithm was applied for the accurate identification of kinematic parameter errors. Finally, several experiments were conducted to evaluate the performance of the proposed hybrid observability index O6. The average position error and average attitude error of Staubli TX60 robot were reduced by 89% and 49%. The results show that the proposed hybrid observability index O6 has great stability and effectiveness for robot calibration.
Open AccessPose Selection Based on a Hybrid Observation Index for Robotic Accuracy Improvement
The problem of the insufficient accuracy performance of industrial robots in high-precision manufacturing is addressed in this paper. Firstly, a kinematic error model based on an M-DH model was presented. Secondly, a hybrid observability index O6 was proposed to select the optimal poses for parameter identification. O6 is the combination of O1 and O3. The optimal poses were obtained by using the IOOPS algorithm. Thirdly, the fitness function for parameter identification was established, and the Levenberg–Marquardt (LM) algorithm was applied for the accurate identification of kinematic parameter errors. Finally, several experiments were conducted to evaluate the performance of the proposed hybrid observability index O6. The average position error and average attitude error of Staubli TX60 robot were reduced by 89% and 49%. The results show that the proposed hybrid observability index O6 has great stability and effectiveness for robot calibration.
- Open Access
- 28 November 2023
- Published by MDPI AG in Mathematics
- Vol. 11 (23) , 4802
Kinematics Parameter Calibration of Serial Industrial Robots Based on Partial Pose Measurement
The kinematics parameter error is the main error factor that affects the absolute accuracy of industrial robots. The absolute accuracy of industrial robots can be effectively improved through kinematics calibration. The error model-based method is one of the main methods for calibrating the kinematics parameter error. This paper presents a kinematics parameter calibration method for serial industrial robots based on partial pose measurement. Firstly, the kinematics and the pose error models have been established based on the modified Denavit–Hartenberg (MDH) model. By introducing the concept of error sensitivity, the average significance index is proposed to quantitatively analyze the effects of the kinematics parameter error on the pose error of a robot. The results show that there is no need to measure the full pose error of the robot. Secondly, a partial pose measurement device and method have been presented. The proposed device can measure the position error and the attitude error on the x-axis or y-axis. Finally, the full pose error model, the NP-type partial pose error model, and the OP-type partial pose error model have been applied for calibrating the kinematics parameter errors. The experimental results show that the effectiveness of the OP-type partial pose error model is consistent with the full pose error model.
- 28 November 2023
- Published by MDPI AG in Mathematics
- Vol. 11 (23) , 4802
Open AccessKinematics Parameter Calibration of Serial Industrial Robots Based on Partial Pose Measurement
The kinematics parameter error is the main error factor that affects the absolute accuracy of industrial robots. The absolute accuracy of industrial robots can be effectively improved through kinematics calibration. The error model-based method is one of the main methods for calibrating the kinematics parameter error. This paper presents a kinematics parameter calibration method for serial industrial robots based on partial pose measurement. Firstly, the kinematics and the pose error models have been established based on the modified Denavit–Hartenberg (MDH) model. By introducing the concept of error sensitivity, the average significance index is proposed to quantitatively analyze the effects of the kinematics parameter error on the pose error of a robot. The results show that there is no need to measure the full pose error of the robot. Secondly, a partial pose measurement device and method have been presented. The proposed device can measure the position error and the attitude error on the x-axis or y-axis. Finally, the full pose error model, the NP-type partial pose error model, and the OP-type partial pose error model have been applied for calibrating the kinematics parameter errors. The experimental results show that the effectiveness of the OP-type partial pose error model is consistent with the full pose error model.