Hayato Fukui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hayato Fukui has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Osamu Dohi
Molecular Gastroenterology and Hepatology, Graduate School of Medical Science Kyoto Prefectural University of Medicine Kyoto Japan
7 shared publications Hideyuki Konishi
Molecular Gastroenterology and Hepatology, Graduate School of Medical Science Kyoto Prefectural University of Medicine Kyoto Japan
3 shared publicationsKatsuma Yamauchi
Molecular Gastroenterology and Hepatology, Graduate School of Medical Science Kyoto Prefectural University of Medicine Kyoto Japan
3 shared publications- Ken Inoue
Molecular Gastroenterology and Hepatology, Graduate School of Medical Science Kyoto Prefectural University of Medicine Kyoto Japan
3 shared publications Mayuko Seya
Molecular Gastroenterology and Hepatology, Graduate School of Medical Science Kyoto Prefectural University of Medicine Kyoto Japan
3 shared publications- Naohisa Yoshida
Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Kyoto, Japan
3 shared publications
Latest Publications
- 6 January 2026
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 41 (2) , 720-726
Scissor‐Type Knife Improves Trainee's Self‐Completion of Endoscopic Submucosal Dissection for Early Gastric Cancer
Background: This retrospective study aimed to verify the efficacy of endoscopic submucosal dissection (ESD) using a scissor‐type knife for early gastric cancer (EGC). Methods: The patients who underwent ESD for EGC between April 2014 and March 2022 were enrolled. The primary endpoint of this study was to assess the efficacy of a scissor‐type knife by comparing the self‐completion rate of trainees between gastric ESD performed using a scissor‐type knife (ESD‐SC) and nonscissor devices (ESD‐NS). Results: Of the 903 lesions, 485 and 418 underwent ESD‐SC and ESD‐NS, respectively. The self‐completion rate of trainees was significantly higher for ESD‐SC than for ESD‐NS (50.3 and 33.0%, respectively; p < 0.001). The procedure time was also significantly shorter for ESD‐SC (50.0 vs. 66.5 min, respectively; p < 0.001). Intraoperative perforation rate was not significantly different (0.6% for ESD‐SC and 1.4% for ESD‐NS, respectively). In multivariate analyses, tumor located in the lower third of the stomach (odds ratio [OR] 1.93, 95% confidence interval [CI] 1.46–2.55, p < 0.001), tumor size ≤ 20 mm (OR 3.32, 95% CI 2.20–5.00, p < 0.001), and a scissor‐type knife (OR 2.22, 95% CI 1.67–2.94, p < 0.001) were factors related to the self‐completion rate of trainees for gastric ESD. Conclusions: A scissor‐type knife was associated with higher self‐completion rates and shorter procedure times among trainees. Further prospective studies are needed to validate its clinical utility in ESD training.
- 6 January 2026
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 41 (2) , 720-726
Scissor‐Type Knife Improves Trainee's Self‐Completion of Endoscopic Submucosal Dissection for Early Gastric Cancer
Background: This retrospective study aimed to verify the efficacy of endoscopic submucosal dissection (ESD) using a scissor‐type knife for early gastric cancer (EGC). Methods: The patients who underwent ESD for EGC between April 2014 and March 2022 were enrolled. The primary endpoint of this study was to assess the efficacy of a scissor‐type knife by comparing the self‐completion rate of trainees between gastric ESD performed using a scissor‐type knife (ESD‐SC) and nonscissor devices (ESD‐NS). Results: Of the 903 lesions, 485 and 418 underwent ESD‐SC and ESD‐NS, respectively. The self‐completion rate of trainees was significantly higher for ESD‐SC than for ESD‐NS (50.3 and 33.0%, respectively; p < 0.001). The procedure time was also significantly shorter for ESD‐SC (50.0 vs. 66.5 min, respectively; p < 0.001). Intraoperative perforation rate was not significantly different (0.6% for ESD‐SC and 1.4% for ESD‐NS, respectively). In multivariate analyses, tumor located in the lower third of the stomach (odds ratio [OR] 1.93, 95% confidence interval [CI] 1.46–2.55, p < 0.001), tumor size ≤ 20 mm (OR 3.32, 95% CI 2.20–5.00, p < 0.001), and a scissor‐type knife (OR 2.22, 95% CI 1.67–2.94, p < 0.001) were factors related to the self‐completion rate of trainees for gastric ESD. Conclusions: A scissor‐type knife was associated with higher self‐completion rates and shorter procedure times among trainees. Further prospective studies are needed to validate its clinical utility in ESD training.
- Open Access
- 1 January 2026
- Published by XMLink in Journal of Gastric Cancer
- Vol. 26 (2) , 232-246
Endoscopic Features of Background Gastritis Associated With Remnant Gastric Cancer: A Multicenter Retrospective Study
Ohashi T, et al. J Gastric Cancer. 2026 Apr;26(2):232-246. https://doi.org/10.5230/jgc.2026.26.e15
- 1 January 2026
- Published by XMLink in Journal of Gastric Cancer
- Vol. 26 (2) , 232-246
Open AccessEndoscopic Features of Background Gastritis Associated With Remnant Gastric Cancer: A Multicenter Retrospective Study
Ohashi T, et al. J Gastric Cancer. 2026 Apr;26(2):232-246. https://doi.org/10.5230/jgc.2026.26.e15
- Open Access
- 23 May 2025
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 40 (8) , 2018-2027
Usefulness of Endoscopic Mucosal Resection Using an Over‐the‐Scope Clip for Duodenal Neuroendocrine Tumors: A Multicenter Retrospective Comparative Study
Background and Aim: Resection of non‐ampullary duodenal neuroendocrine tumors presents technical challenges. This study investigated the efficacy and safety of endoscopic mucosal resection using an over‐the‐scope clip compared to endoscopic mucosal resection with a ligation device and endoscopic submucosal dissection.Methods: This retrospective multicenter study included 65 lesions (63 patients), categorized by resection method: endoscopic mucosal resection using an over‐the‐scope clip (n = 26), endoscopic mucosal resection using a ligation device (n = 17), and endoscopic submucosal dissection (n = 22). Patient characteristics, tumor details, and outcomes were systematically evaluated, with significance at p < 0.05.Results: Endoscopic mucosal resection using an over‐the‐scope clip had a significantly shorter procedure time than endoscopic submucosal dissection (16 min [7–30] vs. 60 min [28–119], p < 0.001) and recorded no perforations. Endoscopic mucosal resection using a ligation device was employed for smaller lesions, while endoscopic submucosal dissection had challenges in achieving clear margins. Hospitalization duration was the longest for the endoscopic submucosal dissection group (endoscopic mucosal resection using an over‐the‐scope clip: 4 [3–7] days, endoscopic mucosal resection using a ligation device: 5 [4–8] days, endoscopic submucosal dissection: 7 [4–15] days, p < 0.001). Endoscopic mucosal resection using an over‐the‐scope clip exhibited a unique advantage for full‐thickness resection.Conclusions: Endoscopic mucosal resection using an over‐the‐scope clip allows for full‐thickness resection with fewer complications. While effective, endoscopic mucosal resection using a ligation device is less reliable for achieving clear vertical margins, and endoscopic submucosal dissection, suitable for larger tumors, has a longer duration and higher complication rate.
- 23 May 2025
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 40 (8) , 2018-2027
Open AccessUsefulness of Endoscopic Mucosal Resection Using an Over‐the‐Scope Clip for Duodenal Neuroendocrine Tumors: A Multicenter Retrospective Comparative Study
Background and Aim: Resection of non‐ampullary duodenal neuroendocrine tumors presents technical challenges. This study investigated the efficacy and safety of endoscopic mucosal resection using an over‐the‐scope clip compared to endoscopic mucosal resection with a ligation device and endoscopic submucosal dissection.Methods: This retrospective multicenter study included 65 lesions (63 patients), categorized by resection method: endoscopic mucosal resection using an over‐the‐scope clip (n = 26), endoscopic mucosal resection using a ligation device (n = 17), and endoscopic submucosal dissection (n = 22). Patient characteristics, tumor details, and outcomes were systematically evaluated, with significance at p < 0.05.Results: Endoscopic mucosal resection using an over‐the‐scope clip had a significantly shorter procedure time than endoscopic submucosal dissection (16 min [7–30] vs. 60 min [28–119], p < 0.001) and recorded no perforations. Endoscopic mucosal resection using a ligation device was employed for smaller lesions, while endoscopic submucosal dissection had challenges in achieving clear margins. Hospitalization duration was the longest for the endoscopic submucosal dissection group (endoscopic mucosal resection using an over‐the‐scope clip: 4 [3–7] days, endoscopic mucosal resection using a ligation device: 5 [4–8] days, endoscopic submucosal dissection: 7 [4–15] days, p < 0.001). Endoscopic mucosal resection using an over‐the‐scope clip exhibited a unique advantage for full‐thickness resection.Conclusions: Endoscopic mucosal resection using an over‐the‐scope clip allows for full‐thickness resection with fewer complications. While effective, endoscopic mucosal resection using a ligation device is less reliable for achieving clear vertical margins, and endoscopic submucosal dissection, suitable for larger tumors, has a longer duration and higher complication rate.
- 26 December 2024
- Published by Wiley in Digestive Endoscopy
- Vol. 37 (5) , 524-531
Endoscopic hemostasis with a self‐assembling peptide gel during endoscopic submucosal dissection and cold‐snare polypectomy in the duodenum: Prospective exploratory study (with video)
Objectives: A novel self‐assembling peptide gel (SAPG) was recently developed for hemostasis during endoscopic resection (ER) as an alternative for electrocoagulation and clip placement. Therefore, this exploratory study aimed to evaluate the hemostatic effect of SAPG on bleeding during ER of the duodenum.Methods: Patients with superficial duodenal epithelial tumors who underwent endoscopic submucosal dissection (ESD) or cold‐snare polypectomy (CSP) between June 2022 and October 2023 were enrolled in the study. SAPG was used for hemostasis of the intraprocedural bleeding when spontaneous hemostasis was essential for the continuation of ESD or was not achieved within 30 s after CSP. The primary outcome was a successful hemostatic rate using SAPG.Results: Among the included patients, 15 and 8 underwent ESD and CSP, respectively. Forty‐two points of intraoperative bleeding were noted during ESD, of which 39 (92.9%) and 3 (7.1%) were oozing and nonspurting bleedings, respectively. Successful hemostatic rates were 84.6% and 0% in the oozing and nonspurting bleedings, respectively. All nonspurting bleedings were weakened after SAPG use. Of the 70 CSPs, 60 were oozing bleedings (85.7%), which were successfully stopped with SAPG. The median time to hemostasis from SAPG application was 30 s (interquartile range [IQR] 17–40 s) and 25 s (IQR 10–33 s) during ESD and CSP, respectively. No adverse event was observed in any of the cases during the perioperative period.Conclusion: Self‐assembling peptide gel has an acceptable effect of successful hemostasis for intraoperative oozing bleeding during duodenal ESD and CSP.
- 26 December 2024
- Published by Wiley in Digestive Endoscopy
- Vol. 37 (5) , 524-531
Endoscopic hemostasis with a self‐assembling peptide gel during endoscopic submucosal dissection and cold‐snare polypectomy in the duodenum: Prospective exploratory study (with video)
Objectives: A novel self‐assembling peptide gel (SAPG) was recently developed for hemostasis during endoscopic resection (ER) as an alternative for electrocoagulation and clip placement. Therefore, this exploratory study aimed to evaluate the hemostatic effect of SAPG on bleeding during ER of the duodenum.Methods: Patients with superficial duodenal epithelial tumors who underwent endoscopic submucosal dissection (ESD) or cold‐snare polypectomy (CSP) between June 2022 and October 2023 were enrolled in the study. SAPG was used for hemostasis of the intraprocedural bleeding when spontaneous hemostasis was essential for the continuation of ESD or was not achieved within 30 s after CSP. The primary outcome was a successful hemostatic rate using SAPG.Results: Among the included patients, 15 and 8 underwent ESD and CSP, respectively. Forty‐two points of intraoperative bleeding were noted during ESD, of which 39 (92.9%) and 3 (7.1%) were oozing and nonspurting bleedings, respectively. Successful hemostatic rates were 84.6% and 0% in the oozing and nonspurting bleedings, respectively. All nonspurting bleedings were weakened after SAPG use. Of the 70 CSPs, 60 were oozing bleedings (85.7%), which were successfully stopped with SAPG. The median time to hemostasis from SAPG application was 30 s (interquartile range [IQR] 17–40 s) and 25 s (IQR 10–33 s) during ESD and CSP, respectively. No adverse event was observed in any of the cases during the perioperative period.Conclusion: Self‐assembling peptide gel has an acceptable effect of successful hemostasis for intraoperative oozing bleeding during duodenal ESD and CSP.
- 25 February 2024
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 39 (6) , 1065-1072
Surveillance esophagogastroduodenoscopy using linked color imaging and narrow‐band imaging: A multicenter randomized controlled trial
Background and Aim: There has been no report on a direct comparison between linked color imaging (LCI) and second‐generation narrow‐band imaging (2G‐NBI) for surveillance of epithelial neoplasms in the upper gastrointestinal tract (UGIT). The aim of this study was to verify the superiority of LCI to 2G‐NBI for surveillance esophagogastroduodenoscopy and to clarify how each endoscopic system should be used.Methods: This study was conducted as an open‐label, two‐arm‐parallel (1:1), multicenter, randomized controlled trial at six institutions. Patients aged 20–85 years with a treatment history of epithelial neoplasms in the UGIT were recruited. Patients were assigned to a 2G‐NBI group and an LCI group, and esophagogastroduodenoscopy was performed with primary image‐enhanced endoscopy followed by white light imaging (WLI). The primary endpoint was the detection rate of one or more epithelial neoplasms in the primary image‐enhanced endoscopy. A WLI‐detected epithelial neoplasm was defined as a lesion that was detected in only WLI.Results: A total of 372 patients in the 2G‐NBI group and 378 patients in the LCI group were analyzed. Epithelial neoplasms in the UGIT were detected by 2G‐NBI in 18 patients (4.6%) and were detected by LCI in 20 patients (5.3%) (P = 0.87). WLI‐detected epithelial neoplasms were in 11 patients in the 2G‐NBI group (3.0%) and in 1 patient in the LCI group (0.27%) (P = 0.003).Conclusions: Linked color imaging did not show superiority to 2G‐NBI for the detection of epithelial neoplasms. Also, the percentage of WLI‐detected epithelial neoplasms in primary NBI was significantly higher than that in primary LCI.
- 25 February 2024
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 39 (6) , 1065-1072
Surveillance esophagogastroduodenoscopy using linked color imaging and narrow‐band imaging: A multicenter randomized controlled trial
Background and Aim: There has been no report on a direct comparison between linked color imaging (LCI) and second‐generation narrow‐band imaging (2G‐NBI) for surveillance of epithelial neoplasms in the upper gastrointestinal tract (UGIT). The aim of this study was to verify the superiority of LCI to 2G‐NBI for surveillance esophagogastroduodenoscopy and to clarify how each endoscopic system should be used.Methods: This study was conducted as an open‐label, two‐arm‐parallel (1:1), multicenter, randomized controlled trial at six institutions. Patients aged 20–85 years with a treatment history of epithelial neoplasms in the UGIT were recruited. Patients were assigned to a 2G‐NBI group and an LCI group, and esophagogastroduodenoscopy was performed with primary image‐enhanced endoscopy followed by white light imaging (WLI). The primary endpoint was the detection rate of one or more epithelial neoplasms in the primary image‐enhanced endoscopy. A WLI‐detected epithelial neoplasm was defined as a lesion that was detected in only WLI.Results: A total of 372 patients in the 2G‐NBI group and 378 patients in the LCI group were analyzed. Epithelial neoplasms in the UGIT were detected by 2G‐NBI in 18 patients (4.6%) and were detected by LCI in 20 patients (5.3%) (P = 0.87). WLI‐detected epithelial neoplasms were in 11 patients in the 2G‐NBI group (3.0%) and in 1 patient in the LCI group (0.27%) (P = 0.003).Conclusions: Linked color imaging did not show superiority to 2G‐NBI for the detection of epithelial neoplasms. Also, the percentage of WLI‐detected epithelial neoplasms in primary NBI was significantly higher than that in primary LCI.
- 16 January 2024
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 39 (4) , 725-732
Clinical outcomes of the over‐the‐scope clip closure after duodenal endoscopic submucosal dissection: A multicenter retrospective study
Background and Aim: Prophylactic closure with the over‐the‐scope clip (OTSC) after endoscopic submucosal dissection (ESD) of superficial non‐ampullary duodenal epithelial tumors (SNADETs) has been reported to reduce postoperative adverse events (AEs). However, there are few evidences regarding AEs‐associated factors and long‐term outcomes of OTSCs.Methods: From January 2011 to December 2020, 139 consecutive patients with SNADETs who underwent ESD followed by OTSC closure in five institutions were extracted in this retrospective study. The primary endpoint was the rate of postoperative AEs after prophylactic OTSC closure. The secondary endpoints were the complete closure rate, residual rate, and long‐term AEs associated with residual OTSCs.Results: The rate of complete closure of the mucosal defect was 97.3% (142) in 146 SNADETs, which were completely resected by ESD. Postoperative AEs, including delayed bleeding, delayed perforation, and localized peritonitis, occurred in 6.2%, 3.4%, and 2.1% of patients, respectively; however, all of the cases improved without surgical treatment. In the multivariate logistic regression analysis, the use of two or more OTSCs was a significant independent risk factor for postoperative AEs (odds ratio, 2.94; 95% confidence interval, 1.02–8.46; P = 0.046). The residual OTSC rate was 46.4% at 1 year postoperatively, and long‐term AEs included duodenal erosions and ulcers associated with residual OTSCs.Conclusions: Prophylactic closure with OTSCs after duodenal ESD can provide acceptable short‐and long‐term outcomes for preventing postoperative AEs. However, multiple OTSCs were the independent risk factors of postoperative AEs due to the gaps between and near the OTSCs.
- 16 January 2024
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 39 (4) , 725-732
Clinical outcomes of the over‐the‐scope clip closure after duodenal endoscopic submucosal dissection: A multicenter retrospective study
Background and Aim: Prophylactic closure with the over‐the‐scope clip (OTSC) after endoscopic submucosal dissection (ESD) of superficial non‐ampullary duodenal epithelial tumors (SNADETs) has been reported to reduce postoperative adverse events (AEs). However, there are few evidences regarding AEs‐associated factors and long‐term outcomes of OTSCs.Methods: From January 2011 to December 2020, 139 consecutive patients with SNADETs who underwent ESD followed by OTSC closure in five institutions were extracted in this retrospective study. The primary endpoint was the rate of postoperative AEs after prophylactic OTSC closure. The secondary endpoints were the complete closure rate, residual rate, and long‐term AEs associated with residual OTSCs.Results: The rate of complete closure of the mucosal defect was 97.3% (142) in 146 SNADETs, which were completely resected by ESD. Postoperative AEs, including delayed bleeding, delayed perforation, and localized peritonitis, occurred in 6.2%, 3.4%, and 2.1% of patients, respectively; however, all of the cases improved without surgical treatment. In the multivariate logistic regression analysis, the use of two or more OTSCs was a significant independent risk factor for postoperative AEs (odds ratio, 2.94; 95% confidence interval, 1.02–8.46; P = 0.046). The residual OTSC rate was 46.4% at 1 year postoperatively, and long‐term AEs included duodenal erosions and ulcers associated with residual OTSCs.Conclusions: Prophylactic closure with OTSCs after duodenal ESD can provide acceptable short‐and long‐term outcomes for preventing postoperative AEs. However, multiple OTSCs were the independent risk factors of postoperative AEs due to the gaps between and near the OTSCs.
- 11 December 2023
- Published by Wiley in Digestive Endoscopy
- Vol. 36 (2) , 215-220
Underwater clip closure method for mucosal defects after duodenal endoscopic submucosal dissection (with video)
Conventional clip closure of mucosal defects after duodenal endoscopic submucosal dissection decreases the incidence of delayed adverse events, but may result in incomplete closure, depending on size or location. This study aimed to assess the effectiveness of the underwater clip closure method for complete duodenal defect closure without the difficulties associated with conventional closure methods. We investigated 19 patients with 20 lesions who underwent endoscopic submucosal dissection of the duodenum and subsequent mucosal defect closure in underwater conditions at our facility between February 2021 and January 2022. The success rate of the underwater clip closure method was defined as the complete endoscopic closure of the mucosal defect; a success rate of 100% was achieved. The median resected specimen size was 34.3 mm, the median procedure time for mucosal defect closure was 14 min, and the median number of clips used per patient was 12. No delayed adverse events were observed. The underwater clip closure method is a feasible option for complete closure of mucosal defects, regardless of the size or location of a duodenal endoscopic submucosal dissection.
- 11 December 2023
- Published by Wiley in Digestive Endoscopy
- Vol. 36 (2) , 215-220
Underwater clip closure method for mucosal defects after duodenal endoscopic submucosal dissection (with video)
Conventional clip closure of mucosal defects after duodenal endoscopic submucosal dissection decreases the incidence of delayed adverse events, but may result in incomplete closure, depending on size or location. This study aimed to assess the effectiveness of the underwater clip closure method for complete duodenal defect closure without the difficulties associated with conventional closure methods. We investigated 19 patients with 20 lesions who underwent endoscopic submucosal dissection of the duodenum and subsequent mucosal defect closure in underwater conditions at our facility between February 2021 and January 2022. The success rate of the underwater clip closure method was defined as the complete endoscopic closure of the mucosal defect; a success rate of 100% was achieved. The median resected specimen size was 34.3 mm, the median procedure time for mucosal defect closure was 14 min, and the median number of clips used per patient was 12. No delayed adverse events were observed. The underwater clip closure method is a feasible option for complete closure of mucosal defects, regardless of the size or location of a duodenal endoscopic submucosal dissection.