Kazushi Azuma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kazushi Azuma has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Eric Monnet
Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, CO
4 shared publications - Norihiko Ito
Veterinary Medical Center, Tottori University Koyama‐cho Minami Tottori Japan
2 shared publications T. Imagawa
Department of Veterinary Clinical Medicine, School of Veterinary Medicine, Faculty of Agriculture, Tottori University, 4-101 Koyama-Minami, Tottori, Japan, 680-8550
2 shared publications- Takeshi Tsuka
Department of Veterinary Clinical Medicine, Joint Department of Veterinary Medicine, Faculty of Agriculture, Tottori University, Japan
2 shared publications - Tomohiro Osaki
Joint Department of Veterinary Medicine, Faculty of Agriculture, Tottori University, Tottori 680-8553, Japan
2 shared publications - Yasuhiro Okamoto
Okayama University
2 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 264 (6) , 1-5
A commercially available physical simulator can be used to teach canine laparoscopic cholecystectomy with 2-dimensional and 3-dimensional visualization
Objective: To evaluate the feasibility of a commercial simulator to reproduce key steps of canine laparoscopic cholecystectomy, and to compare surgical performance when using 3-D versus 2-D visualization. Methods: 16 gallbladder inserts mounted in a laparoscopic cholecystectomy model were used. Inserts were randomly assigned to 2-D or 3-D visualization groups and placed in a laparoscopic training box. All procedures were performed on a single day in 2022 by 1 American College of Veterinary Surgeons resident who completed prestudy training on the simulator to minimize learning-curve effects. A board-certified surgeon supervised all procedures. Surgical steps included cystic duct dissection, endoclip application, cystic duct transection, and gallbladder removal. Measured outcomes included surgical times for defined intervals, total procedure time, intraoperative complications, and residual simulated liver tissue attached to the gallbladder. Results: Time from instrument insertion to first endoclip placement and total surgical time were significantly shorter with 3-D visualization compared to 2-D, and the differences in medians suggested clinically meaningful improvements in performance. There were no significant group differences in bile leakage, incomplete clipping, or the amount of residual foam attachment. Conclusions: This physical simulator allowed reproduction of most key procedural steps in canine laparoscopic cholecystectomy. Three-dimensional visualization improved surgical efficiency for a trainee operator. Clinical Relevance: The simulator provided a safe, accessible platform for early skills acquisition before progressing to cadaveric or clinical training.
- 1 June 2026
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 264 (6) , 1-5
Open AccessA commercially available physical simulator can be used to teach canine laparoscopic cholecystectomy with 2-dimensional and 3-dimensional visualization
Objective: To evaluate the feasibility of a commercial simulator to reproduce key steps of canine laparoscopic cholecystectomy, and to compare surgical performance when using 3-D versus 2-D visualization. Methods: 16 gallbladder inserts mounted in a laparoscopic cholecystectomy model were used. Inserts were randomly assigned to 2-D or 3-D visualization groups and placed in a laparoscopic training box. All procedures were performed on a single day in 2022 by 1 American College of Veterinary Surgeons resident who completed prestudy training on the simulator to minimize learning-curve effects. A board-certified surgeon supervised all procedures. Surgical steps included cystic duct dissection, endoclip application, cystic duct transection, and gallbladder removal. Measured outcomes included surgical times for defined intervals, total procedure time, intraoperative complications, and residual simulated liver tissue attached to the gallbladder. Results: Time from instrument insertion to first endoclip placement and total surgical time were significantly shorter with 3-D visualization compared to 2-D, and the differences in medians suggested clinically meaningful improvements in performance. There were no significant group differences in bile leakage, incomplete clipping, or the amount of residual foam attachment. Conclusions: This physical simulator allowed reproduction of most key procedural steps in canine laparoscopic cholecystectomy. Three-dimensional visualization improved surgical efficiency for a trainee operator. Clinical Relevance: The simulator provided a safe, accessible platform for early skills acquisition before progressing to cadaveric or clinical training.
- Open Access
- 1 January 2026
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 87 (1) , 1-5
Laparoscopic-assisted fluoroscopic cholangiography is a feasible technique for visualizing the biliary system in canine cadavers
Objective: To assess the feasibility of laparoscopic-assisted fluoroscopic cholangiography for visualizing the biliary system in canine cadavers. Methods: 10 canine cadavers were used. Two 5-mm laparoscopic ports were placed via ventral midline incisions. An 8.5-French pigtail catheter was introduced percutaneously into the gallbladder lumen under laparoscopic guidance. Iohexol contrast medium, diluted in 3 different ratios, was injected, and fluoroscopic images were obtained using a C-arm fluoroscopy unit. Catheters were removed, and gallbladder walls were closed with intracorporeal suturing. Visibility of the cystic duct, hepatic ducts, and common bile duct was graded from excellent to not visible. Results: Catheter placement was successful in all cadavers. Contrast leakage occurred in 4 cadavers. The common bile duct was graded excellent to good in 7 cadavers and not visible in 1, the cystic duct was excellent to good in 8, and the hepatic ducts were excellent to good in 6 and not visible in 2. The 1:2 iohexol dilution provided optimal visualization in this study. Catheter sites were successfully closed with intracorporeal suturing without observed bile leakage. Conclusions: Laparoscopic-assisted fluoroscopic cholangiography is a feasible technique for biliary visualization in canine cadavers, particularly with a 1:2 iohexol dilution. Clinical Relevance: This technique may provide a minimally invasive method for intraoperative biliary assessment in dogs, facilitating identification of anatomy and guidance of surgical procedures. Further studies in live patients are warranted to evaluate safety, effectiveness, and applicability in clinical cases.
- 1 January 2026
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 87 (1) , 1-5
Open AccessLaparoscopic-assisted fluoroscopic cholangiography is a feasible technique for visualizing the biliary system in canine cadavers
Objective: To assess the feasibility of laparoscopic-assisted fluoroscopic cholangiography for visualizing the biliary system in canine cadavers. Methods: 10 canine cadavers were used. Two 5-mm laparoscopic ports were placed via ventral midline incisions. An 8.5-French pigtail catheter was introduced percutaneously into the gallbladder lumen under laparoscopic guidance. Iohexol contrast medium, diluted in 3 different ratios, was injected, and fluoroscopic images were obtained using a C-arm fluoroscopy unit. Catheters were removed, and gallbladder walls were closed with intracorporeal suturing. Visibility of the cystic duct, hepatic ducts, and common bile duct was graded from excellent to not visible. Results: Catheter placement was successful in all cadavers. Contrast leakage occurred in 4 cadavers. The common bile duct was graded excellent to good in 7 cadavers and not visible in 1, the cystic duct was excellent to good in 8, and the hepatic ducts were excellent to good in 6 and not visible in 2. The 1:2 iohexol dilution provided optimal visualization in this study. Catheter sites were successfully closed with intracorporeal suturing without observed bile leakage. Conclusions: Laparoscopic-assisted fluoroscopic cholangiography is a feasible technique for biliary visualization in canine cadavers, particularly with a 1:2 iohexol dilution. Clinical Relevance: This technique may provide a minimally invasive method for intraoperative biliary assessment in dogs, facilitating identification of anatomy and guidance of surgical procedures. Further studies in live patients are warranted to evaluate safety, effectiveness, and applicability in clinical cases.
- Open Access
- 1 September 2024
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 85 (9) , 1-7
Examination of the thickness of the different components of gallbladder wall in cases with mucocele and/or cholecystitis
OBJECTIVE: To assess the thickness of each layer of the gallbladder wall with different diseases in dogs. SAMPLE: 72 gallbladders. METHODS: Retrospective study of dogs that underwent cholecystectomy. Histopathological specimens of the gallbladders were reviewed. Histopathological diagnosis was made as gallbladder mucocele or cholecystitis, and cholecystitis was further categorized into chronic cholecystitis, acute-on-chronic cholecystitis, acute cholecystitis, and necrotic cholecystitis. The thickness of each layer of the gallbladder wall was measured. RESULTS: 22 dogs were diagnosed with gallbladder mucocele without cholecystitis, 24 with gallbladder mucocele and cholecystitis, 20 with only cholecystitis, and 6 as normal. Histopathological subclassification of cholecystitis in 44 gallbladders led to diagnosis of chronic cholecystitis in 21 gallbladders, acute-on-chronic cholecystitis in 10 gallbladders, acute cholecystitis in 6 gallbladders, and necrotic cholecystitis in 7 gallbladders. The thickness of the entire wall of the gallbladder (P < .0001) and the thickness of the mucosa (P < .0001) and subserosa (P < .0001) were affected by the different disease processes. CLINICAL RELEVANCE: Layers of the gallbladder wall were affected by diseases present in the gallbladder. It resulted in a difference in the thickness of the wall of the gallbladder among the gallbladder diseases in this study. Histopathological changes should be taken into consideration before surgery while deciding what technique to use to perform a cholecystectomy.
- 1 September 2024
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 85 (9) , 1-7
Open AccessExamination of the thickness of the different components of gallbladder wall in cases with mucocele and/or cholecystitis
OBJECTIVE: To assess the thickness of each layer of the gallbladder wall with different diseases in dogs. SAMPLE: 72 gallbladders. METHODS: Retrospective study of dogs that underwent cholecystectomy. Histopathological specimens of the gallbladders were reviewed. Histopathological diagnosis was made as gallbladder mucocele or cholecystitis, and cholecystitis was further categorized into chronic cholecystitis, acute-on-chronic cholecystitis, acute cholecystitis, and necrotic cholecystitis. The thickness of each layer of the gallbladder wall was measured. RESULTS: 22 dogs were diagnosed with gallbladder mucocele without cholecystitis, 24 with gallbladder mucocele and cholecystitis, 20 with only cholecystitis, and 6 as normal. Histopathological subclassification of cholecystitis in 44 gallbladders led to diagnosis of chronic cholecystitis in 21 gallbladders, acute-on-chronic cholecystitis in 10 gallbladders, acute cholecystitis in 6 gallbladders, and necrotic cholecystitis in 7 gallbladders. The thickness of the entire wall of the gallbladder (P < .0001) and the thickness of the mucosa (P < .0001) and subserosa (P < .0001) were affected by the different disease processes. CLINICAL RELEVANCE: Layers of the gallbladder wall were affected by diseases present in the gallbladder. It resulted in a difference in the thickness of the wall of the gallbladder among the gallbladder diseases in this study. Histopathological changes should be taken into consideration before surgery while deciding what technique to use to perform a cholecystectomy.
- Open Access
- 20 November 2023
- Published by Wiley in Veterinary Surgery
- Vol. 53 (4) , 695-700
Three‐dimensional versus two‐dimensional laparoscopy for cholecystectomy in a canine cadaveric study
Objective: To compare the effect of three‐dimensional (3D) and two‐dimensional (2D) laparoscopy on surgical time and intraoperative complications during cholecystectomies in canine cadavers.Study design: Experimental prospective study.Animals: Twelve canine cadavers.Methods: The laparoscopic cholecystectomies were performed in canine cadavers with four cannulas and with either 2D or 3D cameras by a single surgeon. The following surgical times were recorded: time from insertion of laparoscopic instruments to first endoclip placement, time from first endoclip placement to second endoclip placement, time from second endoclip placement to complete gall bladder dissection, and total surgical time. The cystic duct length distal to the first endoclip, intraoperative complications, and the amount of liver attached to the gall bladder were also recorded.Results: Time from the insertion of the instruments to the application of the first endoclip was shorter for the 3D group than for the 2D group (p = .016). Other surgical times were not different between groups. There was no difference in the cystic duct length distal to the first endoclip, intraoperative complications, or the amount of liver attachment.Conclusion: Three‐dimensional laparoscopy shortened the time from insertion of the laparoscopic instruments to placement of the first endoclip. However, total surgical time was not affected by the type of camera in laparoscopic cholecystectomy.Clinical significance: Three‐dimensional laparoscopy may be beneficial when performing procedures requiring enhanced spatial orientation. However, this technique did not shorten the total surgical time in this cadaveric study. Further studies in a clinical setting are necessary for the optimization of the future use of 3D laparoscopy.
- 20 November 2023
- Published by Wiley in Veterinary Surgery
- Vol. 53 (4) , 695-700
Open AccessThree‐dimensional versus two‐dimensional laparoscopy for cholecystectomy in a canine cadaveric study
Objective: To compare the effect of three‐dimensional (3D) and two‐dimensional (2D) laparoscopy on surgical time and intraoperative complications during cholecystectomies in canine cadavers.Study design: Experimental prospective study.Animals: Twelve canine cadavers.Methods: The laparoscopic cholecystectomies were performed in canine cadavers with four cannulas and with either 2D or 3D cameras by a single surgeon. The following surgical times were recorded: time from insertion of laparoscopic instruments to first endoclip placement, time from first endoclip placement to second endoclip placement, time from second endoclip placement to complete gall bladder dissection, and total surgical time. The cystic duct length distal to the first endoclip, intraoperative complications, and the amount of liver attached to the gall bladder were also recorded.Results: Time from the insertion of the instruments to the application of the first endoclip was shorter for the 3D group than for the 2D group (p = .016). Other surgical times were not different between groups. There was no difference in the cystic duct length distal to the first endoclip, intraoperative complications, or the amount of liver attachment.Conclusion: Three‐dimensional laparoscopy shortened the time from insertion of the laparoscopic instruments to placement of the first endoclip. However, total surgical time was not affected by the type of camera in laparoscopic cholecystectomy.Clinical significance: Three‐dimensional laparoscopy may be beneficial when performing procedures requiring enhanced spatial orientation. However, this technique did not shorten the total surgical time in this cadaveric study. Further studies in a clinical setting are necessary for the optimization of the future use of 3D laparoscopy.
- 1 November 2019
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 102 (11) , 10105-10118
Reliability of ultrasonographic measurements of bovine sole structures in relation to sole horn thickness, measured by computed tomography, and sole horn hardness
The goal of the present study was to determine the effect of sole horn thickness (SHT) and sole horn hardness (SHD) on ultrasonographic visualization of sole structures in the inner and outer claws of 150 Holstein-Friesian cows, and to evaluate different ultrasound frequencies for this purpose. Ultrasonographic views of the sole structure were considered complete when 3 echogenic lines, representing the ventral surface of the sole horn, the borders of the sole horn and soft-tissue layer, and the ventral surface of the distal phalanx, were seen. The proportion of complete ultrasonographic views of the sole structures, designated as the ultrasonographic visualization proportion (UVP), and the measurement errors of SHT were evaluated by comparing images from computed tomography (CT) and ultrasonography. The latter images were generated using 3 different probes, frequencies of 6.5 and 5.0 MHz, and 2 different ultrasound machines (#1 and #2) to assess the apex, middle, and heel regions of the claws. The UVP were 60.8 to 77.9% for the 6.5-MHz probe in ultrasound machine #1 (probe A), which were lower than those (>90%) for both the 5.0-MHz probe in ultrasound machine #1 (probe B) and the 5.0-MHz probe in ultrasound machine #2 (probe C). The UVP was significantly lower in claws with an SHD ≥50 units than in claws with an SHD <40 or 40 to <50 units (UVP: 77.1% compared with 93.7 and 91.4%, respectively) when measured with probe B. In claws with an SHT <10 mm, the UVP was significantly lower when SHD was ≥50 units compared with 50 units; the values were 69.0% versus 91.3 and 85.9%, respectively, for probe A, and 89.7% versus 100 and 100%, respectively, for probe B. When SHT were measured by either probes A or B in ultrasound machine #1, the proportions of claws in which ultrasonographic values were within a ±1 mm range compared with the values obtained by CT were 84.9 to 91.3% for CT-determined SHT <5 mm, 66.7 to 71.9% for CT-determined SHT 5 to <7 mm, 28.9 to 51.2% for CT-determined SHT 7 to <10 mm, and 6.2 to 19.7% for CT-determined SHT ≥10 mm. The data indicated that increased SHT was associated with a decrease in ultrasonographic measurement accuracy. In claws with an SHT <5 mm, the high proportion of ultrasonographic values that were accurate within a ±1 mm range suggests that this imaging modality would be useful in cows with thin soles.
- 1 November 2019
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 102 (11) , 10105-10118
Reliability of ultrasonographic measurements of bovine sole structures in relation to sole horn thickness, measured by computed tomography, and sole horn hardness
The goal of the present study was to determine the effect of sole horn thickness (SHT) and sole horn hardness (SHD) on ultrasonographic visualization of sole structures in the inner and outer claws of 150 Holstein-Friesian cows, and to evaluate different ultrasound frequencies for this purpose. Ultrasonographic views of the sole structure were considered complete when 3 echogenic lines, representing the ventral surface of the sole horn, the borders of the sole horn and soft-tissue layer, and the ventral surface of the distal phalanx, were seen. The proportion of complete ultrasonographic views of the sole structures, designated as the ultrasonographic visualization proportion (UVP), and the measurement errors of SHT were evaluated by comparing images from computed tomography (CT) and ultrasonography. The latter images were generated using 3 different probes, frequencies of 6.5 and 5.0 MHz, and 2 different ultrasound machines (#1 and #2) to assess the apex, middle, and heel regions of the claws. The UVP were 60.8 to 77.9% for the 6.5-MHz probe in ultrasound machine #1 (probe A), which were lower than those (>90%) for both the 5.0-MHz probe in ultrasound machine #1 (probe B) and the 5.0-MHz probe in ultrasound machine #2 (probe C). The UVP was significantly lower in claws with an SHD ≥50 units than in claws with an SHD <40 or 40 to <50 units (UVP: 77.1% compared with 93.7 and 91.4%, respectively) when measured with probe B. In claws with an SHT <10 mm, the UVP was significantly lower when SHD was ≥50 units compared with 50 units; the values were 69.0% versus 91.3 and 85.9%, respectively, for probe A, and 89.7% versus 100 and 100%, respectively, for probe B. When SHT were measured by either probes A or B in ultrasound machine #1, the proportions of claws in which ultrasonographic values were within a ±1 mm range compared with the values obtained by CT were 84.9 to 91.3% for CT-determined SHT <5 mm, 66.7 to 71.9% for CT-determined SHT 5 to <7 mm, 28.9 to 51.2% for CT-determined SHT 7 to <10 mm, and 6.2 to 19.7% for CT-determined SHT ≥10 mm. The data indicated that increased SHT was associated with a decrease in ultrasonographic measurement accuracy. In claws with an SHT <5 mm, the high proportion of ultrasonographic values that were accurate within a ±1 mm range suggests that this imaging modality would be useful in cows with thin soles.
- 14 January 2016
- Published by Wiley in Veterinary and Comparative Oncology
- Vol. 15 (3) , 731-739
Photodynamic detection of canine mammary gland tumours after oral administration of 5‐aminolevulinic acid
5‐Aminolevulinic acid (5‐ALA) is widely used in photodynamic detection (PDD) and therapy. We evaluated the pharmacokinetics of 5‐ALA‐induced porphyrins and its effectiveness in PDD in dogs with mammary gland tumours (MGTs) following oral administration. Healthy dogs and those with MGTs (nine each) were orally administered 4 mg kg−1 5‐ALA. Protoporphyrin IX (PpIX) was not detected in the plasma of healthy dogs but it peaked in dogs with MGT at 2 h after 5‐ALA administration. In the PDD study, 16 dogs with MGT were orally administered 40 mg kg−1 5‐ALA, and MGT but not normal tissue showed red fluorescence after 2–4 h. Photon counts were 6635–63 890 and 59–4011 (median, 19 943 and 919) for MGT and non‐tumour tissues, respectively. Cell density strongly correlated with PpIX photon counts of MGT tissue of the dogs (R = 0.743, P = 0.0009). We suggest that 5‐ALA‐PDD might be an effective diagnostic tool for MGTs.
- 14 January 2016
- Published by Wiley in Veterinary and Comparative Oncology
- Vol. 15 (3) , 731-739
Photodynamic detection of canine mammary gland tumours after oral administration of 5‐aminolevulinic acid
5‐Aminolevulinic acid (5‐ALA) is widely used in photodynamic detection (PDD) and therapy. We evaluated the pharmacokinetics of 5‐ALA‐induced porphyrins and its effectiveness in PDD in dogs with mammary gland tumours (MGTs) following oral administration. Healthy dogs and those with MGTs (nine each) were orally administered 4 mg kg−1 5‐ALA. Protoporphyrin IX (PpIX) was not detected in the plasma of healthy dogs but it peaked in dogs with MGT at 2 h after 5‐ALA administration. In the PDD study, 16 dogs with MGT were orally administered 40 mg kg−1 5‐ALA, and MGT but not normal tissue showed red fluorescence after 2–4 h. Photon counts were 6635–63 890 and 59–4011 (median, 19 943 and 919) for MGT and non‐tumour tissues, respectively. Cell density strongly correlated with PpIX photon counts of MGT tissue of the dogs (R = 0.743, P = 0.0009). We suggest that 5‐ALA‐PDD might be an effective diagnostic tool for MGTs.