Marianna Pires Barbosa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marianna Pires Barbosa has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Moreira da Silva
Universidade Federal Fluminense, Brazil
2 shared publications - Cristiane Mariote Amaral
Analytical Laboratory of Restorative Biomaterials-LABiom-R, School of Dentistry, Universidade Federal Fluminense, Niterói 24210-240, Brazil
1 shared publication - Renata Nunes Jardim
Analytical Laboratory of Restorative Biomaterials—LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
1 shared publication - Tiago Braga Rabello
Department of Clinics Faculty of Dentistry, Universidade Federal do Rio de Janeiro Rio de Janeiro Brazil
1 shared publication - Tiago Braga Rabello
Department of Dental Clinic, School of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro 24370110, Brazil
1 shared publication
Latest Publications
- Open Access
Influence of Specimen Dimension, Water Immersion Protocol, and Surface Roughness on Water Sorption and Solubility of Resin-Based Restorative Materials
The evaluation of water sorption and solubility is pivotal for the development of new resin-based restorative materials with the potential for clinical application. The purpose of the present study was to evaluate the influence of the specimen dimension, water immersion protocol, and surface roughness on the water sorption and solubility of three resin-based restorative materials. Disk-shaped specimens of 15 mm × 1 mm, 10 mm × 1 mm, and 6 mm × 1 mm were produced with a composite resin (Z100), a resin cement (RelyX ARC), and an adhesive system (Single Bond 2—SB2). The specimens were immersed in distilled water according to four protocols: ISO (all the specimens for each group were vertically immersed in 50 mL); IV-10 (the specimens were individually and vertically immersed in 10 mL); IH-10 (the specimens were individually and horizontally immersed in 10 mL); and IH-2 (the specimens were individually and horizontally immersed in 2 mL). The surface roughness (Sa and Sp) was evaluated using an atomic force microscope, and the degree of conversion was determined using FT-IR spectrometry. The specimen dimension and water immersion protocol had no effect on water sorption and solubility. For the three resin-based restorative materials, Sp was higher than Sa. The degree of conversion was not influenced by the specimen dimension. The variations in the specimen dimension and water immersion protocol compared to those determined by ISO 4049 did not prevent the comparison between the values of water sorption and solubility obtained for a given resin-based restorative material.
Open AccessInfluence of Specimen Dimension, Water Immersion Protocol, and Surface Roughness on Water Sorption and Solubility of Resin-Based Restorative Materials
The evaluation of water sorption and solubility is pivotal for the development of new resin-based restorative materials with the potential for clinical application. The purpose of the present study was to evaluate the influence of the specimen dimension, water immersion protocol, and surface roughness on the water sorption and solubility of three resin-based restorative materials. Disk-shaped specimens of 15 mm × 1 mm, 10 mm × 1 mm, and 6 mm × 1 mm were produced with a composite resin (Z100), a resin cement (RelyX ARC), and an adhesive system (Single Bond 2—SB2). The specimens were immersed in distilled water according to four protocols: ISO (all the specimens for each group were vertically immersed in 50 mL); IV-10 (the specimens were individually and vertically immersed in 10 mL); IH-10 (the specimens were individually and horizontally immersed in 10 mL); and IH-2 (the specimens were individually and horizontally immersed in 2 mL). The surface roughness (Sa and Sp) was evaluated using an atomic force microscope, and the degree of conversion was determined using FT-IR spectrometry. The specimen dimension and water immersion protocol had no effect on water sorption and solubility. For the three resin-based restorative materials, Sp was higher than Sa. The degree of conversion was not influenced by the specimen dimension. The variations in the specimen dimension and water immersion protocol compared to those determined by ISO 4049 did not prevent the comparison between the values of water sorption and solubility obtained for a given resin-based restorative material.
- Open Access
The Influence of Adhesive Strategy, Type of Dental Composite, and Polishing Time on Marginal Gap Formation in Class I-like Cavities
Even after more than six decades of dental composite invention (1962), there is still controversial information about the time in which composite restorations should be polished in order to avoid marginal gap formation at the tooth–composite interface. The aim of the present study was to analyze the influence of adhesive strategy, the type of dental composite, and polishing time on marginal gap formation (%MG) at the tooth–composite interface. Class I-like cavities were hybridized with a universal adhesive system (Single Bond Universal) through two strategies: selective enamel etching (SEE) or self-etching mode (SEM). Cavities were filled with two types of dental composites: nanofilled (Z350) or bulk fill (Filtek One Bulk Fill—ONE), and polishing was performed immediately or delayed for 7 days (n = 5). %MG was evaluated by using a 3D laser confocal microscope. As flexural modulus (FM) and degree of conversion (DC%) are determinants of marginal integrity in dental composite restorations, these properties were evaluated for both composites. Data were analyzed by ANOVA and Tukey’s HSD test (α = 0.05). Cavities hybridized following the SEE strategy presented lower %MG (p < 0.05). Z350 showed higher %MG than ONE (p < 0.05). There was no difference in %MG between the polishing times when the SEE strategy was used (p > 0.05). Z350 presented higher FM than ONE (p < 0.05). DC% was found to be not significant (p > 0.05). The results suggest that selective enamel etching (SEE) is a better strategy for producing less %MG in composite restorations with enamel margins irrespective of the time in which the restoration is polished.
Open AccessThe Influence of Adhesive Strategy, Type of Dental Composite, and Polishing Time on Marginal Gap Formation in Class I-like Cavities
Even after more than six decades of dental composite invention (1962), there is still controversial information about the time in which composite restorations should be polished in order to avoid marginal gap formation at the tooth–composite interface. The aim of the present study was to analyze the influence of adhesive strategy, the type of dental composite, and polishing time on marginal gap formation (%MG) at the tooth–composite interface. Class I-like cavities were hybridized with a universal adhesive system (Single Bond Universal) through two strategies: selective enamel etching (SEE) or self-etching mode (SEM). Cavities were filled with two types of dental composites: nanofilled (Z350) or bulk fill (Filtek One Bulk Fill—ONE), and polishing was performed immediately or delayed for 7 days (n = 5). %MG was evaluated by using a 3D laser confocal microscope. As flexural modulus (FM) and degree of conversion (DC%) are determinants of marginal integrity in dental composite restorations, these properties were evaluated for both composites. Data were analyzed by ANOVA and Tukey’s HSD test (α = 0.05). Cavities hybridized following the SEE strategy presented lower %MG (p < 0.05). Z350 showed higher %MG than ONE (p < 0.05). There was no difference in %MG between the polishing times when the SEE strategy was used (p > 0.05). Z350 presented higher FM than ONE (p < 0.05). DC% was found to be not significant (p > 0.05). The results suggest that selective enamel etching (SEE) is a better strategy for producing less %MG in composite restorations with enamel margins irrespective of the time in which the restoration is polished.