Aaron D. Seims
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Aaron D. Seims has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Amos Hong Pheng Loh
Department of Paediatric Surgery, KK Women's and Children's Hospital, Singapore
1 shared publication Carroll M. Harmon
Women and Children's Hospital of Buffalo, Buffalo, New York
1 shared publicationColin A. Martin
Children's of Alabama, Birmingham, Alabama
1 shared publication- David A. Rogers
University of Alabama at Birmingham Heersink School of Medicine Birmingham USA
1 shared publication - Elizabeth A. Beierle
Division of Pediatric Surgery, Department of Surgery, University of Alabama at Birmingham, Birmingham, AL 35233, USA
1 shared publication Emily Ulloa
Department of Surgery, Arnold Palmer Hospital for Children, Orlando, Florida, USA
1 shared publication
Latest Publications
- 1 June 2024
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 34 (6) , 530-534
Utilization of Single-Incision Laparoscopy in the Management of Ingested Magnets
Background: A ban on neodymium magnets was lifted by the U.S. Consumer Product Safety Commission in 2016. Pediatric gastroenterologists and surgeons were increasingly tasked with removing these problematic objects. The purpose of this study was to assess the utility of single-incision laparoscopic surgery (SILS) in the management of ingested magnets. Patients and Methods: This is a single-center, retrospective assessment of surgical interventions for ingested magnets. International Classification of Disease, 10th revision codes were used to identify 349 patients ≤21 years of age evaluated for foreign body ingestion over a 4.5-year period. A medical record review helped isolate 29 (8.3%) magnet ingestions, 9 requiring surgical intervention. RedCap was used for analysis. Results: Of 9 surgical patients, 7 underwent SILS intervention by 1 surgeon. Another surgeon performed an open operation, whereas a third performed a multiport operation. Of the 7 SILS cases, 3 were completed without conversion to open. In one of these cases, bowel resection with primary anastomosis was performed. For SILS cases, average operating room time was 109 minutes (38–170 minutes), time to enteral feeds was 23 hours (0.28–79.2 hours), and hospital length of stay (LOS) was 3.8 days (1.96–6.68 days). Thirty-day readmission for SILS was 14.3%. No other complications were observed. Conclusions: SILS has been safely utilized for magnet retrieval. It offers an ability to identify the affected intestinal segment and an opportunity to intervene extracorporeally through an uncapped port. In addition, knowing where matted bowel is located can direct a limited incision during conversion to laparotomy. This may confer benefits of decreased pain, shortened time to enteral feeds, and decreased hospital LOS.
- 1 June 2024
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 34 (6) , 530-534
Utilization of Single-Incision Laparoscopy in the Management of Ingested Magnets
Background: A ban on neodymium magnets was lifted by the U.S. Consumer Product Safety Commission in 2016. Pediatric gastroenterologists and surgeons were increasingly tasked with removing these problematic objects. The purpose of this study was to assess the utility of single-incision laparoscopic surgery (SILS) in the management of ingested magnets. Patients and Methods: This is a single-center, retrospective assessment of surgical interventions for ingested magnets. International Classification of Disease, 10th revision codes were used to identify 349 patients ≤21 years of age evaluated for foreign body ingestion over a 4.5-year period. A medical record review helped isolate 29 (8.3%) magnet ingestions, 9 requiring surgical intervention. RedCap was used for analysis. Results: Of 9 surgical patients, 7 underwent SILS intervention by 1 surgeon. Another surgeon performed an open operation, whereas a third performed a multiport operation. Of the 7 SILS cases, 3 were completed without conversion to open. In one of these cases, bowel resection with primary anastomosis was performed. For SILS cases, average operating room time was 109 minutes (38–170 minutes), time to enteral feeds was 23 hours (0.28–79.2 hours), and hospital length of stay (LOS) was 3.8 days (1.96–6.68 days). Thirty-day readmission for SILS was 14.3%. No other complications were observed. Conclusions: SILS has been safely utilized for magnet retrieval. It offers an ability to identify the affected intestinal segment and an opportunity to intervene extracorporeally through an uncapped port. In addition, knowing where matted bowel is located can direct a limited incision during conversion to laparotomy. This may confer benefits of decreased pain, shortened time to enteral feeds, and decreased hospital LOS.
- 1 February 2017
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 27 (2) , 206-210
Operative and Immediate Postoperative Differences Between Traditional Multiport and Reduced Port Laparoscopic Total Splenectomy in Pediatric Patients
Background: Laparoscopy offers many benefits to splenectomy, such as reduced incisional pain and shortened hospital duration. The purpose of this study is to evaluate procedural and outcome differences between multiport (MP) and reduced port (RP) splenectomy when utilized to treat children. Patients and Methods: An institutional review board approved retrospective analysis of all consecutive laparoscopic total splenectomies performed at a single institution between January 2010 and October 2015 was conducted. We evaluated demographics, surgical technique, instance of conversion, operative duration, estimated blood loss, need for intraoperative blood transfusion, postoperative length of stay, time to full feeds, complications, and follow-up duration. Results: Over a 5-year period, 66 patients less than 20 years of age underwent laparoscopic total splenectomy. RP splenectomy was attempted in 14 patients. The remaining 52 were MP operations. Populations were comparable with regard to demographics. Preoperative splenic volumes (mL) were greater in the RP population (median [IQR]: 1377 [747–1508] versus 452 [242–710], P = .039). RP splenectomy demonstrated no difference compared to MP splenectomy in operative time (153 versus 138 minutes, P = .360), estimated blood loss (120 versus 154 mL, P = .634), or percent of cases requiring intraoperative blood transfusion (14 versus 23, P = .716). By the first postoperative day, 57% of RP and 17% of MP patients could be discharged (P = .005). Thirty-day readmission rates were similar, at 7% for RP and 8% for MP operations. Fever was the indication for all readmissions. Mean duration of follow-up is 28 months for MP and 13 months for RP cases. Conclusion: A reduced number of ports can be safely utilized for total splenectomy in pediatric patients without increasing procedural duration or need for intraoperative blood transfusion. In addition, rate of discharge on the first postoperative day was significantly higher in the RP splenectomy group.
- 1 February 2017
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 27 (2) , 206-210
Operative and Immediate Postoperative Differences Between Traditional Multiport and Reduced Port Laparoscopic Total Splenectomy in Pediatric Patients
Background: Laparoscopy offers many benefits to splenectomy, such as reduced incisional pain and shortened hospital duration. The purpose of this study is to evaluate procedural and outcome differences between multiport (MP) and reduced port (RP) splenectomy when utilized to treat children. Patients and Methods: An institutional review board approved retrospective analysis of all consecutive laparoscopic total splenectomies performed at a single institution between January 2010 and October 2015 was conducted. We evaluated demographics, surgical technique, instance of conversion, operative duration, estimated blood loss, need for intraoperative blood transfusion, postoperative length of stay, time to full feeds, complications, and follow-up duration. Results: Over a 5-year period, 66 patients less than 20 years of age underwent laparoscopic total splenectomy. RP splenectomy was attempted in 14 patients. The remaining 52 were MP operations. Populations were comparable with regard to demographics. Preoperative splenic volumes (mL) were greater in the RP population (median [IQR]: 1377 [747–1508] versus 452 [242–710], P = .039). RP splenectomy demonstrated no difference compared to MP splenectomy in operative time (153 versus 138 minutes, P = .360), estimated blood loss (120 versus 154 mL, P = .634), or percent of cases requiring intraoperative blood transfusion (14 versus 23, P = .716). By the first postoperative day, 57% of RP and 17% of MP patients could be discharged (P = .005). Thirty-day readmission rates were similar, at 7% for RP and 8% for MP operations. Fever was the indication for all readmissions. Mean duration of follow-up is 28 months for MP and 13 months for RP cases. Conclusion: A reduced number of ports can be safely utilized for total splenectomy in pediatric patients without increasing procedural duration or need for intraoperative blood transfusion. In addition, rate of discharge on the first postoperative day was significantly higher in the RP splenectomy group.
- 1 March 2015
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 25 (3) , 252-255
Routine Utilization of Single-Incision Pediatric Endosurgery (SIPES): A 5-Year Institutional Experience
Single-incision pediatric endosurgery (SIPES) allows operation through one access site, eliminating the multiple sites traditionally used. There are few large series evaluating the versatility of SIPES. The purpose of this study is to review a 5-year single-institution experience with routine SIPES use. This is an Institutional Review Board-approved retrospective analysis of prospectively collected data. All SIPES cases from March 2009 to December 2013 were included. Our database contains demographics, procedure type, operative duration, estimated blood loss, instance of added ports or conversion to open, complications, and follow-up duration. Of 1322 SIPES operations performed, most (82.1%) were appendectomies and cholecystectomies. Of 871 (66%) patients seen in follow-up, with a median duration of 26 days, 53 (6.1%) experienced postoperative complications. Forty-two cases (4.8%) were surgical-site infections, of which 4 required drainage. Less frequent complications that required operative intervention include recurrent inguinal hernia (n=4), umbilical hernia (n=3), intraabdominal abscess (n=1), bleeding (n=1), abdominal compartment syndrome (n=1), bowel obstruction (n=1), stitch granuloma (n=1), and persistent postoperative pain (n=1). Operative times and complication rates are comparable to those in prior reported multiport laparoscopic series, allowing safe integration of SIPES into the routine of a surgical practice for most common procedures.
- 1 March 2015
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 25 (3) , 252-255
Routine Utilization of Single-Incision Pediatric Endosurgery (SIPES): A 5-Year Institutional Experience
Single-incision pediatric endosurgery (SIPES) allows operation through one access site, eliminating the multiple sites traditionally used. There are few large series evaluating the versatility of SIPES. The purpose of this study is to review a 5-year single-institution experience with routine SIPES use. This is an Institutional Review Board-approved retrospective analysis of prospectively collected data. All SIPES cases from March 2009 to December 2013 were included. Our database contains demographics, procedure type, operative duration, estimated blood loss, instance of added ports or conversion to open, complications, and follow-up duration. Of 1322 SIPES operations performed, most (82.1%) were appendectomies and cholecystectomies. Of 871 (66%) patients seen in follow-up, with a median duration of 26 days, 53 (6.1%) experienced postoperative complications. Forty-two cases (4.8%) were surgical-site infections, of which 4 required drainage. Less frequent complications that required operative intervention include recurrent inguinal hernia (n=4), umbilical hernia (n=3), intraabdominal abscess (n=1), bleeding (n=1), abdominal compartment syndrome (n=1), bowel obstruction (n=1), stitch granuloma (n=1), and persistent postoperative pain (n=1). Operative times and complication rates are comparable to those in prior reported multiport laparoscopic series, allowing safe integration of SIPES into the routine of a surgical practice for most common procedures.