Fan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fan Zhang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jie Gao
NARI Technology Company Ltd., Nanjing, China
6 shared publications - Xiaowei Wang
School of Electrical Engineering, Xian University of Technology, Xian, China
6 shared publications - Xiangxiang Wei
School of Electrical Engineering, Xian University of Technology, Xian, China
5 shared publications - Yizhao Wang
State Grid Shaanxi Electric Power Research Institute, Xian, China
4 shared publications Xinqian Wang
Xi’an University of Technology
3 shared publications- Xinglin Gan
Xi’an Xinghui Electric Power Technology Company Ltd
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 5080-5092
Inner-Product-Based Detection of Cross-Line Successive Single-Phase-to-Ground Faults in Resonant Active Distribution Networks
Existing protection schemes often fail to detect cross-line successive single-phase-to-ground (SSPG) faults in resonant-grounded active distribution networks, due to the severely weakened transient signature that results when a secondary fault (f2) superimposes on an uncleared primary fault (f1). To address this, a novel detection method based on inner-product analysis is proposed. First, a transient equivalent circuit for the f2 fault is established. Expressions for the transient zero-sequence currents in healthy, primary, and secondary fault feeders, as well as for the bus zero-sequence voltage, are subsequently derived and analyzed. Then, the inner-product is applied to reveal the inherent correlation between healthy and faulty feeders during an f1 fault. For the f2 fault, distinct dynamic patterns, specifically in the amplitude and polarity of the inner products, are revealed for the primary, and secondary fault feeders. This analysis provides the theoretical foundation for SSPG fault detection. Furthermore, a differential preprocessing algorithm is introduced to enhance transient signatures, thereby improving the reliability of the inner-product based detection. Simulation and field test results confirm that the proposed method accurately detects both the f1 and f2 faults under challenging conditions, including short fault intervals, diverse grounding resistance combinations, distributed generation integration, arc faults, and strong noise interference.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 5080-5092
Inner-Product-Based Detection of Cross-Line Successive Single-Phase-to-Ground Faults in Resonant Active Distribution Networks
Existing protection schemes often fail to detect cross-line successive single-phase-to-ground (SSPG) faults in resonant-grounded active distribution networks, due to the severely weakened transient signature that results when a secondary fault (f2) superimposes on an uncleared primary fault (f1). To address this, a novel detection method based on inner-product analysis is proposed. First, a transient equivalent circuit for the f2 fault is established. Expressions for the transient zero-sequence currents in healthy, primary, and secondary fault feeders, as well as for the bus zero-sequence voltage, are subsequently derived and analyzed. Then, the inner-product is applied to reveal the inherent correlation between healthy and faulty feeders during an f1 fault. For the f2 fault, distinct dynamic patterns, specifically in the amplitude and polarity of the inner products, are revealed for the primary, and secondary fault feeders. This analysis provides the theoretical foundation for SSPG fault detection. Furthermore, a differential preprocessing algorithm is introduced to enhance transient signatures, thereby improving the reliability of the inner-product based detection. Simulation and field test results confirm that the proposed method accurately detects both the f1 and f2 faults under challenging conditions, including short fault intervals, diverse grounding resistance combinations, distributed generation integration, arc faults, and strong noise interference.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (5) , 3789-3801
A Cross-Line Successive Fault Detection of Distribution Network Based on Zero-Sequence Capacitance Variation
In non-effectively grounded system, the rise in phase voltage during single-phase grounding (SPG) fault poses a significant threat to the system’s insulation integrity. The increasing cabling rate in distribution network has led to a rising proportion of cross-line double successive single-phase grounding (SSPG) faults triggered by initial fault. To address the challenges of weak characteristic and difficult detection of such successive fault, this paper proposes a SSPG detection method based on zero-sequence capacitance variation. First, the dynamic zero-sequence equivalent network during successive faults is simplified, and derive the zero-sequence current (ZSC) expressions for each feeder under both overdamped and underdamped conditions. Subsequently, the singular value decomposition-total least squares extended Prony algorithm is employed to fit the zero-sequence voltage (ZSV) and ZSC, enabling the calculation of zero-sequence capacitance for both initial and successive faults in the complex frequency domain. A detection criterion is then constructed using the variation of capacitance. Finally, digital simulations and recorded field data validate the correctness and feasibility of the theoretical analysis.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (5) , 3789-3801
A Cross-Line Successive Fault Detection of Distribution Network Based on Zero-Sequence Capacitance Variation
In non-effectively grounded system, the rise in phase voltage during single-phase grounding (SPG) fault poses a significant threat to the system’s insulation integrity. The increasing cabling rate in distribution network has led to a rising proportion of cross-line double successive single-phase grounding (SSPG) faults triggered by initial fault. To address the challenges of weak characteristic and difficult detection of such successive fault, this paper proposes a SSPG detection method based on zero-sequence capacitance variation. First, the dynamic zero-sequence equivalent network during successive faults is simplified, and derive the zero-sequence current (ZSC) expressions for each feeder under both overdamped and underdamped conditions. Subsequently, the singular value decomposition-total least squares extended Prony algorithm is employed to fit the zero-sequence voltage (ZSV) and ZSC, enabling the calculation of zero-sequence capacitance for both initial and successive faults in the complex frequency domain. A detection criterion is then constructed using the variation of capacitance. Finally, digital simulations and recorded field data validate the correctness and feasibility of the theoretical analysis.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (4) , 2832-2844
Detection of High-Impedance Faults in Active Distribution Networks With Flexible Grounding
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (4) , 2832-2844
Detection of High-Impedance Faults in Active Distribution Networks With Flexible Grounding
- 26 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (5) , 2611-2623
Pole-to-Ground Fault Protection Scheme for Flexible DC Distribution Network Based on Time Domain Skewness and Integral Energy
For the multi terminal flexible DC distribution network based on modular multilevel converters, if the line fails and is not cut off in time, it will damage power electronic devices and may burn out the converter station. It is difficult to accurately distinguish between internal high resistance faults and external low resistance faults when faults occur in multi terminal flexible DC distribution networks. Analyzed the equivalent model and equation of zero-mode current at each measurement point in the time domain and complex frequency domain when a grounding fault occurs in the system. Based on this, a flexible DC distribution network grounding protection method based on time domain skewness and integral energy is proposed. Using the zero-mode current skewness symbol at each measuring point to characterize directional characteristics, and the integrated energy of the line to characterize amplitude characteristics. Using integrated energy as a supplement to skewness criteria can accurately extract fault features and perform fault identification in extreme cases where a certain line is long. Finally, a four-terminal flexible DC power grid model was built on the PSCAD/EMTDC simulation platform to verify the adaptability and superiority of the protection method.
- 26 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (5) , 2611-2623
Pole-to-Ground Fault Protection Scheme for Flexible DC Distribution Network Based on Time Domain Skewness and Integral Energy
For the multi terminal flexible DC distribution network based on modular multilevel converters, if the line fails and is not cut off in time, it will damage power electronic devices and may burn out the converter station. It is difficult to accurately distinguish between internal high resistance faults and external low resistance faults when faults occur in multi terminal flexible DC distribution networks. Analyzed the equivalent model and equation of zero-mode current at each measurement point in the time domain and complex frequency domain when a grounding fault occurs in the system. Based on this, a flexible DC distribution network grounding protection method based on time domain skewness and integral energy is proposed. Using the zero-mode current skewness symbol at each measuring point to characterize directional characteristics, and the integrated energy of the line to characterize amplitude characteristics. Using integrated energy as a supplement to skewness criteria can accurately extract fault features and perform fault identification in extreme cases where a certain line is long. Finally, a four-terminal flexible DC power grid model was built on the PSCAD/EMTDC simulation platform to verify the adaptability and superiority of the protection method.
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Cross-Line Same-Phase Successive Faults Detection in Flexible Grounding Distribution Systems Based on Vertical and Horizontal Criteria
When cross-line same-phase successive faults (CSSF) occur in a distribution network, the second fault makes the zero-sequence voltage consistently exceed 15% of the phase voltage, resulting in the existing detection devices not being able to return, which makes the fault persist for a long time and endangers the stable operation of the power grid. To address this problem, we propose a fault detection method based on vertical and horizontal double criteria. Firstly, zero-sequence current and voltage features are analyzed for a flexible grounding system when the grounding mode changes during the CSSF period. Secondly, constructing two boundary cases calculates the zero-sequence admittance modulus of the first and second faulty feeders. Finally, vertical criterion 1 is constructed because the fault feeder’s zero-sequence admittance modulus is greater than the healthy feeder. Horizontal criterion 2 is constructed because the faulty feeder’s zero-sequence admittance modulus ratio is greater than the healthy feeder. PSCAD simulations and field tests show that the method can accurately detect CSSF in flexible grounding systems without being affected by current transformer reversal, missing data, strong noise and intermittent arcing.
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Cross-Line Same-Phase Successive Faults Detection in Flexible Grounding Distribution Systems Based on Vertical and Horizontal Criteria
When cross-line same-phase successive faults (CSSF) occur in a distribution network, the second fault makes the zero-sequence voltage consistently exceed 15% of the phase voltage, resulting in the existing detection devices not being able to return, which makes the fault persist for a long time and endangers the stable operation of the power grid. To address this problem, we propose a fault detection method based on vertical and horizontal double criteria. Firstly, zero-sequence current and voltage features are analyzed for a flexible grounding system when the grounding mode changes during the CSSF period. Secondly, constructing two boundary cases calculates the zero-sequence admittance modulus of the first and second faulty feeders. Finally, vertical criterion 1 is constructed because the fault feeder’s zero-sequence admittance modulus is greater than the healthy feeder. Horizontal criterion 2 is constructed because the faulty feeder’s zero-sequence admittance modulus ratio is greater than the healthy feeder. PSCAD simulations and field tests show that the method can accurately detect CSSF in flexible grounding systems without being affected by current transformer reversal, missing data, strong noise and intermittent arcing.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-15
A Denoising Method for Cable Partial Discharge Signals Based on Image Information Entropy and Multivariate Variational Mode Decomposition
Crosslinked polyethylene (XLPE) insulated cables have been widely developed in transmission lines and urban distribution networks due to their advantages, such as being lightweight, high working temperature, and high transmission power. Partial discharge (PD) detection is the primary means to evaluate the insulation status of XLPE cables. This article proposes a denoising method based on image information entropy (IIE) and a novel adaptive multivariate variational mode decomposition (MVMD) to address the issues of white noise, periodic narrowband interference, and weak adaptability. The method first decomposes the signal based on MVMD, reconstructs and converts it into a grayscale, and then calculates the information entropy. Considering the efficiency of execution, the modal parameters of the algorithm are optimized by combining the correlation coefficient with IIE. Second, the PD feature information is distinguished from the noise interference component by calculating the kurtosis of each intrinsic mode function (IMF) to determine its dominant component’s property characteristics and utilizing the kurtosis’s sensitivity to noise. Then, the noise interference component is subjected to $3\sigma $ criteria filtering. Finally, the denoised signal is obtained through a novel, improved wavelet threshold algorithm. The denoising effect of this method is validated by comparing it with several existing methods. The results show that this method has good noise suppression performance for on-site PD signals, with low time consumption, high execution efficiency, and high engineering application value.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-15
A Denoising Method for Cable Partial Discharge Signals Based on Image Information Entropy and Multivariate Variational Mode Decomposition
Crosslinked polyethylene (XLPE) insulated cables have been widely developed in transmission lines and urban distribution networks due to their advantages, such as being lightweight, high working temperature, and high transmission power. Partial discharge (PD) detection is the primary means to evaluate the insulation status of XLPE cables. This article proposes a denoising method based on image information entropy (IIE) and a novel adaptive multivariate variational mode decomposition (MVMD) to address the issues of white noise, periodic narrowband interference, and weak adaptability. The method first decomposes the signal based on MVMD, reconstructs and converts it into a grayscale, and then calculates the information entropy. Considering the efficiency of execution, the modal parameters of the algorithm are optimized by combining the correlation coefficient with IIE. Second, the PD feature information is distinguished from the noise interference component by calculating the kurtosis of each intrinsic mode function (IMF) to determine its dominant component’s property characteristics and utilizing the kurtosis’s sensitivity to noise. Then, the noise interference component is subjected to $3\sigma $ criteria filtering. Finally, the denoised signal is obtained through a novel, improved wavelet threshold algorithm. The denoising effect of this method is validated by comparing it with several existing methods. The results show that this method has good noise suppression performance for on-site PD signals, with low time consumption, high execution efficiency, and high engineering application value.