Maysen E. Calzon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Maysen E. Calzon has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Christopher Pittman
University of South Florida Morsani College of Medicine, Tampa, FL; Vein911 Vein Treatment Centers, Tampa, FL
2 shared publications John Blebea
Department of Surgery, Saginaw, Central Michigan University College of Medicine, MI, USA
2 shared publications- Bilal Koussayer
University of South Florida Health Morsani College of Medicine, Tampa, USA
1 shared publication Christopher Pittman
USF Health Morsani College of Medicine, Tampa, FL, USA
1 shared publicationEsaan Azizi
University of South Florida Morsani College of Medicine, Tampa, FL
1 shared publication- Jin-Ju Lee
University of South Florida Morsani College of Medicine, Tampa, FL
1 shared publication
Latest Publications
- Open Access
- 23 October 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 14 (1) , 102347
General and disease-specific quality-of-life improvement following superficial venous insufficiency treatment
- 23 October 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 14 (1) , 102347
Open AccessGeneral and disease-specific quality-of-life improvement following superficial venous insufficiency treatment
- 30 May 2024
- Published by SAGE Publications in Phlebology: The Journal of Venous Disease
- Vol. 39 (8) , 557-563
Detection and quantitation of venous leg edema with the edema ruler and ultrasound
Objective: Lower extremity edema is characteristic of C3 chronic venous disease. We developed a new clinical and duplex ultrasound (DUS) methodology for the detection and quantification of leg edema and prospectively evaluated its usefulness. Methods: Forty-seven venous patients (94 legs) were evaluated for ankle edema using an Edema Ruler TM and DUS using a modified Suehiro grading scale. Results: Interobserver reliability for the use of the Edema Ruler TM was 0.985 ( p < .001) and 0.883 ( p < .001) for the Modified Suehiro Grade. The Edema Ruler TM had stronger significant correlations with Edema rVCSS (0.842; p < .001) compared to DUS: (0.474; p < .001) with Edema rVCSS. There were significant differences between the edema pitting depth in CEAP classification of C1 and C2 compared to C3, C4a, and C4c. DUS analysis only had significant differences between CEAP classification C2 and C4a. Conclusions: The Edema Ruler TM provides a quantitative measurement of lower extremity edema with high reliability which can be easily integrated into clinical practice. While both methods had good inter-observer reliability, the Edema Ruler TM had stronger correlations to Edema rVCSS and showed significant differences in pitting depths between lower CEAP scores (C1-2) compared to higher CEAP scores (C3-4c).
- 30 May 2024
- Published by SAGE Publications in Phlebology: The Journal of Venous Disease
- Vol. 39 (8) , 557-563
Detection and quantitation of venous leg edema with the edema ruler and ultrasound
Objective: Lower extremity edema is characteristic of C3 chronic venous disease. We developed a new clinical and duplex ultrasound (DUS) methodology for the detection and quantification of leg edema and prospectively evaluated its usefulness. Methods: Forty-seven venous patients (94 legs) were evaluated for ankle edema using an Edema Ruler TM and DUS using a modified Suehiro grading scale. Results: Interobserver reliability for the use of the Edema Ruler TM was 0.985 ( p < .001) and 0.883 ( p < .001) for the Modified Suehiro Grade. The Edema Ruler TM had stronger significant correlations with Edema rVCSS (0.842; p < .001) compared to DUS: (0.474; p < .001) with Edema rVCSS. There were significant differences between the edema pitting depth in CEAP classification of C1 and C2 compared to C3, C4a, and C4c. DUS analysis only had significant differences between CEAP classification C2 and C4a. Conclusions: The Edema Ruler TM provides a quantitative measurement of lower extremity edema with high reliability which can be easily integrated into clinical practice. While both methods had good inter-observer reliability, the Edema Ruler TM had stronger correlations to Edema rVCSS and showed significant differences in pitting depths between lower CEAP scores (C1-2) compared to higher CEAP scores (C3-4c).
- 9 December 2023
- Published by Springer Nature in Updates in Surgery
- Vol. 76 (2) , 719-722
How I do it: robotic hiatal hernia repair with stapled conversion from Nissen to Toupet fundoplication
The purpose of this paper is to describe a robotic surgical technique for converting a slipped Nissen fundoplication to a Toupet fundoplication. Our technique utilizes four 8 mm robotic ports placed in a horizontal pattern above the umbilicus. The robotic tools we used are a vessel sealer, bipolar forceps, and Cadière forceps. In addition, an esophagogastroduodenoscopy (EGD) is placed through the esophagus into the stomach to be used as a bougie. If a hernia is present, we dissect it from the mediastinum until the posterior confluence is identified. Next sutures from the previous Nissen fundoplication are identified and removed to mobilize the crus. All adhesions around the stomach are removed to mobilize the esophagus, ensuing 3 cm of intraabdominal esophagus is available. Using an EGD as a bougie, we used two interrupted, 0 silk suture over Teflon pledgets placed in a horizontal mattress fashion to close the hiatal defect. Using an endoscope, we identified the previous Nissen fundoplication and used a 60 mm blue load stapler to transect the wrap from the stomach. The 360° Nissen fundoplication had now been converted into a 270° Toupet fundoplication, which is confirmed with the EGD. The functionality of the wrap is confirmed if the “Stack of Coins” sign is present, and the wrap lies tight against the scope. A Nissen-to-Toupet fundoplication conversion using a robotic-assisted surgical technique may be useful in reducing reoperations and complications in patients undergoing fundoplication surgery.
- 9 December 2023
- Published by Springer Nature in Updates in Surgery
- Vol. 76 (2) , 719-722
How I do it: robotic hiatal hernia repair with stapled conversion from Nissen to Toupet fundoplication
The purpose of this paper is to describe a robotic surgical technique for converting a slipped Nissen fundoplication to a Toupet fundoplication. Our technique utilizes four 8 mm robotic ports placed in a horizontal pattern above the umbilicus. The robotic tools we used are a vessel sealer, bipolar forceps, and Cadière forceps. In addition, an esophagogastroduodenoscopy (EGD) is placed through the esophagus into the stomach to be used as a bougie. If a hernia is present, we dissect it from the mediastinum until the posterior confluence is identified. Next sutures from the previous Nissen fundoplication are identified and removed to mobilize the crus. All adhesions around the stomach are removed to mobilize the esophagus, ensuing 3 cm of intraabdominal esophagus is available. Using an EGD as a bougie, we used two interrupted, 0 silk suture over Teflon pledgets placed in a horizontal mattress fashion to close the hiatal defect. Using an endoscope, we identified the previous Nissen fundoplication and used a 60 mm blue load stapler to transect the wrap from the stomach. The 360° Nissen fundoplication had now been converted into a 270° Toupet fundoplication, which is confirmed with the EGD. The functionality of the wrap is confirmed if the “Stack of Coins” sign is present, and the wrap lies tight against the scope. A Nissen-to-Toupet fundoplication conversion using a robotic-assisted surgical technique may be useful in reducing reoperations and complications in patients undergoing fundoplication surgery.
- Open Access
- 21 November 2023
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 10 (1) , 101373
Quantitative measurement of pitting edema with a novel edema ruler
- 21 November 2023
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 10 (1) , 101373
Open AccessQuantitative measurement of pitting edema with a novel edema ruler