ZZZhangang Zhang

Zhangang Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhangang Zhang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Chao Peng

    China Electronic Product Reliability and Environmental Testing Research Institute 1 , Guangzhou 510610

    3 shared publications
  • Zhifeng Lei

    Science and Technology on Reliability Physics and Application of Electronic Component Laboratory, China Electronic Product Reliability and Environmental Testing Research Institute, Guangzhou 511370, China

    3 shared publications
  • Hong Zhang

    Science and Technology on Reliability Physics and Application of Electronic Component Laboratory, China Electronic Product Reliability and Environmental Testing Research Institute, Guangzhou 511370, China

    2 shared publications
  • Teng Ma

    Science and Technology on Reliability Physics and Application of Electronic Component Laboratory, China Electronic Product Reliability and Environmental Testing Research Institute, Guangzhou 511370, China

    2 shared publications
  • Xiangli Zhong

    Xiangtan University

    2 shared publications
  • Daming Wang

    State Key Laboratory of HVDC Transmission Technology, China Southern Power Grid Electric Power Research Institute Co., Ltd., Guangzhou 510663, China

    1 shared publication

Latest Publications

  • Open Access

    Effect of Cosmic Rays on the Failure Rate of Flexible Direct Current Converter Valves in High-Altitude Environment

    by Liu Yang, Zezhao Zhang, Yuebin Zhou, Daming Wang, Chao Peng, Hong Zhang, Zhifeng Lei, Zhangang Zhang, Weili Fu, Teng Ma

    Aiming at the significant needs of flexible DC converter valve applications in high-altitude areas, we investigate the effect of atmospheric neutrons on the failure rate of key core power devices in three kinds of converter valves, namely IGBTs, thyristors, and diodes. The safe working voltage boundary of the devices is obtained, and the failure rate caused by atmospheric neutrons in the real working environment of the power devices is calculated according to the results of the ground-accelerated irradiation test of atmospheric neutrons and the atmospheric neutron environment under the actual working conditions. The test results show that the failure rate of IGBTs, thyristors, and diodes caused by atmospheric neutrons is greatly affected by the blocking voltage, and the larger the blocking voltage is, the higher the failure rate of the device is. The research results can provide a basis for the design of the operating voltage of key core power devices of flexible DC converter valves and guide the evaluation of the failure rate and engineering design of the electronic system of DC ultra-high-voltage power transmission and transformation converter stations in the high-altitude environment of the Qinghai-Tibet Plateau.


  • Open Access

    Temperature Dependence of Total Ionizing Dose Effects of β-Ga2O3 Schottky Barrier Diodes

    by Weili Fu, Teng Ma, Zhifeng Lei, Chao Peng, Hong Zhang, Zhangang Zhang, Tao Xiao, Hongjia Song, Yuangang Wang, Jinbin Wang, et al.

    This paper investigates the temperature-dependent effects of gamma-ray irradiation on β-Ga2O3 vertical Schottky barrier diodes (SBDs) under a 100 V reverse bias condition at a total dose of 1 Mrad(Si). As the irradiation dose increased, the radiation damage became more severe. The total ionizing dose (TID) degradation behavior and mechanisms were evaluated through DC, capacitance–voltage (C-V), and low-frequency noise (LFN) measurements by varying irradiation, and the test results indicated that TID effects introduced interface defects and altered the carrier concentration within the material. The impact of TID effects was more pronounced at lower temperatures compared to higher temperatures. Additionally, the annealing effect in the high-temperature experimental conditions ameliorated the growth of interface trap defects caused by irradiation. These results suggest that compared to low-temperature testing, the device exhibits higher TID tolerance after high-temperature exposure, providing valuable insights for in-depth radiation reliability studies on subsequent related devices.


  • Open Access

    Study of High-Energy Proton Irradiation Effects in Top-Gate Graphene Field-Effect Transistors

    by Xiaojie Lu, Hongxia Guo, Zhifeng Lei, Chao Peng, Zhangang Zhang, Hong Zhang, Teng Ma, Yahui Feng, Wuying Ma, Xiangli Zhong, et al.

    In this article, the effects of high-energy proton irradiation on top-gate graphene field-effect transistors (GFETs) were investigated by using 20 MeV protons. The basic electrical parameters of the top-gate GFETs were measured before and after proton irradiation with a fluence of 1 × 1011 p/cm2 and 5 × 1011 p/cm2, respectively. Decreased saturation current, increased Dirac sheet resistance, and negative drift in the Dirac voltage in response to proton irradiation were observed. According to the transfer characteristic curves, it was found that the carrier mobility was reduced after proton irradiation. The analysis suggests that proton irradiation generates a large net positive charge in the gate oxide layer, which induces a negative drift in the Dirac voltage. Introducing defects and increased impurities at the gate oxide/graphene interface after proton irradiation resulted in enhanced Coulomb scattering and reduced mobility of the carriers, which in turn affects the Dirac sheet resistance and saturation current. After annealing at room temperature, the electrical characteristics of the devices were partially restored. The results of the technical computer-aided design (TCAD) simulation indicate that the reduction in carrier mobility is the main reason for the degradation of the electrical performance of the device. Monte Carlo simulations were conducted to determine the ionization and nonionization energy losses induced by proton incidence in top-gate GFET devices. The simulation data show that the ionization energy loss is the primary cause of the degradation of the electrical performance.