NBNicolai Brekenfeld

Nicolai Brekenfeld

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nicolai Brekenfeld has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Technical note: High-frequency, multi-elemental stream water monitoring – experiences, feedbacks and suggestions from 7 years of running three French field laboratories (Riverlabs)

    by Nicolai Brekenfeld, Solenn Cotel, Mikael Faucheux, Colin Fourtet, Yannick Hamon, Patrice Petitjean, Arnaud Blanchouin, Celine Bouillis, Marie-Claire Pierret, Hocine Henine, et al.

    High-frequency and multi-elemental stream water monitoring are acknowledged as necessary to address data limitation in the fields of catchment sciences and freshwater biogeochemistry. In recent years, the development of stream bank analyzers and on-site field laboratories to measure various solutes and/or isotopes at sub-hourly measurement intervals has been in progress at an increasing number of sites. This trend should likely persist in the future as the technologies are still improving. Here we share our experiences of running three innovative lab-in-the-field prototypes, called Riverlabs, which consist of a field deployment involving continuous sampling and filtration of stream water and its analysis using laboratory instruments such as ion chromatographs. This note gives an overview of the technical and organizational points that we identify as critical because we claim that such practical considerations are generally missing in the literature in order to provide guidelines for the successful implementation of future projects running such or similar field-laboratory setups. We share the main stages in the deployment of this tool in the field, the difficulties encountered and the proposed solutions. Our two main conclusions for a successful, long-term functioning of these types of field laboratories are, first, the necessity to adapt several central components of the field laboratory to the local conditions (climate, river geometry, topography, physico-chemical characteristics of water, power supply) and, second, the need of diverse and in-depth technical skills within the engineering team. The critical aspects discussed here relate to (1) supply of the field laboratory – basic functioning of the pumping, filtration and analytical systems; (2) data quality control and assurance via maintenance services and operations; (3) data harmonization and coordination of the laboratory components; and (4) team structure, skills and organization. We believe that sharing these experiences, combined with providing some practical suggestions, might be useful for colleagues who are starting to deploy such or similar field laboratories. These considerations will save time, improve performance and ensure continuous field monitoring.


  • Open Access

    Using high-frequency solute synchronies to determine simple two-end-member mixing in catchments during storm events

    by Nicolai Brekenfeld, Solenn Cotel, Mikaël Faucheux, Paul Floury, Colin Fourtet, Jérôme Gaillardet, Sophie Guillon, Yannick Hamon, Hocine Henine, Patrice Petitjean, et al.

    Stream water chemistry at catchment outlets is commonly used to infer flow paths of water through catchments and to quantify the relative contributions of various flow paths and/or end-members, especially during storm events. For this purpose, the number and nature of these flow paths or end-members are commonly determined with principal component analysis based on all available conservative solute data in inverse end-member mixing analyses (EMMAs). However, apart from the selection of conservative solutes, little attention is paid to the number and choice of the solutes that are included in the analysis, despite the impact this choice can have on the interpretation of the results from an inverse EMMA. Here, we propose a methodology that tries to fill this gap. For a given pair of measured solutes, the proposed methodology determines the minimum number of required end-members, based on the synchronous variation of the solutes during storm events. This allows identification of solute pairs for which a simple two-end-member mixing model is sufficient to explain their variation during storm events and of solute pairs, which show a more complex pattern requiring a higher-order end-member mixing model. We analyse the concentration–concentration relationships of several major ion pairs on the storm-event scale, using multi-year, high-frequency (< 60 min) monitoring data from the outlet of two small (0.8 to 5 km2) French catchments with contrasting land use, climate, and geology. A large number of storm events (56 % to 79 %) could be interpreted as being the result of a mixture of only two end-members, depending on the catchment and the ion pairs used. Even though some of these results could have been expected (e.g. a two-end-member model for the Na+/Cl- pair in a catchment close to the Atlantic coast), others were more surprising and in contrast to previous studies. These findings might help to revise or improve perceptual catchment understanding of flow path or end-member contributions and of biogeochemical processes. In addition, this methodology can identify which solute pairs are governed by identical hydro-biogeochemical processes and which solutes are modified by more complex and diverse processes.


  • Open Access

    Reply on RC2

    by Ophélie Fovet, Nicolai Brekenfeld, Solenn Cotel, Mikael Faucheux, Colin Fourtet, Yannick Hamon, Patrice Petitjean, Arnaud Blanchouin, Celine Bouillis, Marie-Claire Pierret, et al.

    High-frequency and multi-elemental stream water monitoring are acknowledged as necessary to address data limitation in the fields of catchment sciences and freshwater biogeochemistry. In recent years, the development of stream bank analyzers and on-site field laboratories to measure various solutes and/or isotopes at sub-hourly measurement intervals is in progress at an increasing number of sites. This trend should likely persist in the future. Here, we share our experiences of running three French field laboratories (called Riverlabs) over seven years. This technical note gives an overview of the technical and organizational points that we identify as critical in order to provide guidelines for the successful implementation of future projects running such equipment. We therefore share the main stages in the deployment of this tool in the field, the difficulties we encountered and the procedures we used to identify and eliminate their causes. Some of the critical aspects discussed here relate to 1) Supply of the field laboratory: basic functioning of the pumping, filtration and analytical systems, 2) Data quality control and assurance via maintenance services and operations, 3) Data harmonization and coordination of the laboratory components, and 4) Team structure, skills and organization. Our two main conclusions for a successful, long-term functioning of these types of field laboratories are, first, the necessity to adapt several central components of the field laboratory to the local conditions (climate, section, topography, water turbidity, power) and, second, the need of diverse and in-depth technical skills within the engineering team. We believe that sharing these experiences, combined with providing some practical suggestions might be useful for colleagues, who are starting to deploy such or similar field laboratories. These considerations will save time, improve performance and ensure continuous field monitoring.

  • Open Access

    Reply on RC1

    by Ophélie Fovet, Nicolai Brekenfeld, Solenn Cotel, Mikael Faucheux, Colin Fourtet, Yannick Hamon, Patrice Petitjean, Arnaud Blanchouin, Celine Bouillis, Marie-Claire Pierret, et al.

    High-frequency and multi-elemental stream water monitoring are acknowledged as necessary to address data limitation in the fields of catchment sciences and freshwater biogeochemistry. In recent years, the development of stream bank analyzers and on-site field laboratories to measure various solutes and/or isotopes at sub-hourly measurement intervals is in progress at an increasing number of sites. This trend should likely persist in the future. Here, we share our experiences of running three French field laboratories (called Riverlabs) over seven years. This technical note gives an overview of the technical and organizational points that we identify as critical in order to provide guidelines for the successful implementation of future projects running such equipment. We therefore share the main stages in the deployment of this tool in the field, the difficulties we encountered and the procedures we used to identify and eliminate their causes. Some of the critical aspects discussed here relate to 1) Supply of the field laboratory: basic functioning of the pumping, filtration and analytical systems, 2) Data quality control and assurance via maintenance services and operations, 3) Data harmonization and coordination of the laboratory components, and 4) Team structure, skills and organization. Our two main conclusions for a successful, long-term functioning of these types of field laboratories are, first, the necessity to adapt several central components of the field laboratory to the local conditions (climate, section, topography, water turbidity, power) and, second, the need of diverse and in-depth technical skills within the engineering team. We believe that sharing these experiences, combined with providing some practical suggestions might be useful for colleagues, who are starting to deploy such or similar field laboratories. These considerations will save time, improve performance and ensure continuous field monitoring.

  • Open Access

    Comment on egusphere-2024-902

    by Nicolai Brekenfeld, Solenn Cotel, Mikael Faucheux, Colin Fourtet, Yannick Hamon, Patrice Petitjean, Arnaud Blanchouin, Celine Bouillis, Marie-Claire Pierret, Hocine Henine, et al.

    High-frequency and multi-elemental stream water monitoring are acknowledged as necessary to address data limitation in the fields of catchment sciences and freshwater biogeochemistry. In recent years, the development of stream bank analyzers and on-site field laboratories to measure various solutes and/or isotopes at sub-hourly measurement intervals is in progress at an increasing number of sites. This trend should likely persist in the future. Here, we share our experiences of running three French field laboratories (called Riverlabs) over seven years. This technical note gives an overview of the technical and organizational points that we identify as critical in order to provide guidelines for the successful implementation of future projects running such equipment. We therefore share the main stages in the deployment of this tool in the field, the difficulties we encountered and the procedures we used to identify and eliminate their causes. Some of the critical aspects discussed here relate to 1) Supply of the field laboratory: basic functioning of the pumping, filtration and analytical systems, 2) Data quality control and assurance via maintenance services and operations, 3) Data harmonization and coordination of the laboratory components, and 4) Team structure, skills and organization. Our two main conclusions for a successful, long-term functioning of these types of field laboratories are, first, the necessity to adapt several central components of the field laboratory to the local conditions (climate, section, topography, water turbidity, power) and, second, the need of diverse and in-depth technical skills within the engineering team. We believe that sharing these experiences, combined with providing some practical suggestions might be useful for colleagues, who are starting to deploy such or similar field laboratories. These considerations will save time, improve performance and ensure continuous field monitoring.

  • Open Access

    Technical Note on high-frequency, multi-elemental stream water monitoring: experiences, feedbacks, and suggestions from seven years of running three French field laboratories (Riverlabs)

    by Nicolai Brekenfeld, Solenn Cotel, Mikael Faucheux, Colin Fourtet, Yannick Hamon, Patrice Petitjean, Arnaud Blanchouin, Celine Bouillis, Marie-Claire Pierret, Hocine Henine, et al.

    High-frequency and multi-elemental stream water monitoring are acknowledged as necessary to address data limitation in the fields of catchment sciences and freshwater biogeochemistry. In recent years, the development of stream bank analyzers and on-site field laboratories to measure various solutes and/or isotopes at sub-hourly measurement intervals is in progress at an increasing number of sites. This trend should likely persist in the future. Here, we share our experiences of running three French field laboratories (called Riverlabs) over seven years. This technical note gives an overview of the technical and organizational points that we identify as critical in order to provide guidelines for the successful implementation of future projects running such equipment. We therefore share the main stages in the deployment of this tool in the field, the difficulties we encountered and the procedures we used to identify and eliminate their causes. Some of the critical aspects discussed here relate to 1) Supply of the field laboratory: basic functioning of the pumping, filtration and analytical systems, 2) Data quality control and assurance via maintenance services and operations, 3) Data harmonization and coordination of the laboratory components, and 4) Team structure, skills and organization. Our two main conclusions for a successful, long-term functioning of these types of field laboratories are, first, the necessity to adapt several central components of the field laboratory to the local conditions (climate, section, topography, water turbidity, power) and, second, the need of diverse and in-depth technical skills within the engineering team. We believe that sharing these experiences, combined with providing some practical suggestions might be useful for colleagues, who are starting to deploy such or similar field laboratories. These considerations will save time, improve performance and ensure continuous field monitoring.

  • Open Access

    Reply on RC2

    by Nicolai Brekenfeld, Solenn Cotel, Mikaël Faucheux, Paul Floury, Colin Fourtet, Jérôme Gaillardet, Sophie Guillon, Yannick Hamon, Hocine Henine, Patrice Petitjean, et al.

    Stream water chemistry at catchment outlets is commonly used to infer the flow paths of water through the catchment and to quantify the relative contributions of various flow paths and/or end-members, especially during storm events. For this purpose, the number and nature of these flow paths or end-members are commonly determined with principal component analysis based on all available conservative solute data. Here, for a given pair of measured solutes, we propose a methodology to determine the minimum number of required end-members, based on the ion’s synchronous variation during storm events. This allows identifying solute pairs, for which a simple two end-member mixing model is sufficient to explain their variation during storm events and solute pairs, which show a more complex pattern, requiring a higher-order end-member mixing model. We analysed the concentration-concentration relationships of several major ion pairs on the storm-event scale, using multi-year, high-frequency (< 60 minutes) monitoring data from the outlet of two small (0.8 to 5 km²) French catchments with contrasting land-use, climate and geology. A large number of storm-events (56 to 92 %) could be interpreted as the result of the mixture of only two end-members, depending on the catchment and the ion pairs used. Even though some of these results could have been expected (e.g. a two-end-member model for the Na+/Cl- pair in a catchment close to the Atlantic coast), others were more surprising and in contrast to previous studies. These findings might help to revise or improve the perceptual catchment understanding of flow path or end-member contributions and of biogeochemical processes. In addition, this methodology can identify, which solute pairs are governed by identical hydro-biogeochemical processes and which solutes are modified by more complex and diverse processes.

  • Open Access

    Reply on RC1

    by Nicolai Brekenfeld, Solenn Cotel, Mikaël Faucheux, Paul Floury, Colin Fourtet, Jérôme Gaillardet, Sophie Guillon, Yannick Hamon, Hocine Henine, Patrice Petitjean, et al.

    Stream water chemistry at catchment outlets is commonly used to infer the flow paths of water through the catchment and to quantify the relative contributions of various flow paths and/or end-members, especially during storm events. For this purpose, the number and nature of these flow paths or end-members are commonly determined with principal component analysis based on all available conservative solute data. Here, for a given pair of measured solutes, we propose a methodology to determine the minimum number of required end-members, based on the ion’s synchronous variation during storm events. This allows identifying solute pairs, for which a simple two end-member mixing model is sufficient to explain their variation during storm events and solute pairs, which show a more complex pattern, requiring a higher-order end-member mixing model. We analysed the concentration-concentration relationships of several major ion pairs on the storm-event scale, using multi-year, high-frequency (< 60 minutes) monitoring data from the outlet of two small (0.8 to 5 km²) French catchments with contrasting land-use, climate and geology. A large number of storm-events (56 to 92 %) could be interpreted as the result of the mixture of only two end-members, depending on the catchment and the ion pairs used. Even though some of these results could have been expected (e.g. a two-end-member model for the Na+/Cl- pair in a catchment close to the Atlantic coast), others were more surprising and in contrast to previous studies. These findings might help to revise or improve the perceptual catchment understanding of flow path or end-member contributions and of biogeochemical processes. In addition, this methodology can identify, which solute pairs are governed by identical hydro-biogeochemical processes and which solutes are modified by more complex and diverse processes.

  • Open Access

    Comment on egusphere-2023-2214

    by Nicolai Brekenfeld, Solenn Cotel, Mikaël Faucheux, Paul Floury, Colin Fourtet, Jérôme Gaillardet, Sophie Guillon, Yannick Hamon, Hocine Henine, Patrice Petitjean, et al.

    Stream water chemistry at catchment outlets is commonly used to infer the flow paths of water through the catchment and to quantify the relative contributions of various flow paths and/or end-members, especially during storm events. For this purpose, the number and nature of these flow paths or end-members are commonly determined with principal component analysis based on all available conservative solute data. Here, for a given pair of measured solutes, we propose a methodology to determine the minimum number of required end-members, based on the ion’s synchronous variation during storm events. This allows identifying solute pairs, for which a simple two end-member mixing model is sufficient to explain their variation during storm events and solute pairs, which show a more complex pattern, requiring a higher-order end-member mixing model. We analysed the concentration-concentration relationships of several major ion pairs on the storm-event scale, using multi-year, high-frequency (< 60 minutes) monitoring data from the outlet of two small (0.8 to 5 km²) French catchments with contrasting land-use, climate and geology. A large number of storm-events (56 to 92 %) could be interpreted as the result of the mixture of only two end-members, depending on the catchment and the ion pairs used. Even though some of these results could have been expected (e.g. a two-end-member model for the Na+/Cl- pair in a catchment close to the Atlantic coast), others were more surprising and in contrast to previous studies. These findings might help to revise or improve the perceptual catchment understanding of flow path or end-member contributions and of biogeochemical processes. In addition, this methodology can identify, which solute pairs are governed by identical hydro-biogeochemical processes and which solutes are modified by more complex and diverse processes.

  • Open Access

    Using high-frequency solute synchronies to determine simple two-end-member mixing in catchments during storm events

    by Nicolai Brekenfeld, Solenn Cotel, Mikaël Faucheux, Paul Floury, Colin Fourtet, Jérôme Gaillardet, Sophie Guillon, Yannick Hamon, Hocine Henine, Patrice Petitjean, et al.

    Stream water chemistry at catchment outlets is commonly used to infer the flow paths of water through the catchment and to quantify the relative contributions of various flow paths and/or end-members, especially during storm events. For this purpose, the number and nature of these flow paths or end-members are commonly determined with principal component analysis based on all available conservative solute data. Here, for a given pair of measured solutes, we propose a methodology to determine the minimum number of required end-members, based on the ion’s synchronous variation during storm events. This allows identifying solute pairs, for which a simple two end-member mixing model is sufficient to explain their variation during storm events and solute pairs, which show a more complex pattern, requiring a higher-order end-member mixing model. We analysed the concentration-concentration relationships of several major ion pairs on the storm-event scale, using multi-year, high-frequency (< 60 minutes) monitoring data from the outlet of two small (0.8 to 5 km²) French catchments with contrasting land-use, climate and geology. A large number of storm-events (56 to 92 %) could be interpreted as the result of the mixture of only two end-members, depending on the catchment and the ion pairs used. Even though some of these results could have been expected (e.g. a two-end-member model for the Na+/Cl- pair in a catchment close to the Atlantic coast), others were more surprising and in contrast to previous studies. These findings might help to revise or improve the perceptual catchment understanding of flow path or end-member contributions and of biogeochemical processes. In addition, this methodology can identify, which solute pairs are governed by identical hydro-biogeochemical processes and which solutes are modified by more complex and diverse processes.