B. C. Foo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
B. C. Foo has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Maria Gatu Johnson
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
11 shared publications - Benjamin L. Reichelt
Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
10 shared publications - Johan A. Frenje
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
10 shared publications - M. Cufari
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
10 shared publications - Skylar G. Dannhoff
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
10 shared publications - Timothy Mark Johnson
Lawrence Livermore National Laboratory 2 , Livermore, California 94550
10 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Evaluation of the high-performance TechnoTrak CR-39 for detection of 1–9 MeV fusion protons
In this paper, the MeV-proton response of a high-sensitivity, low-noise CR-39 nuclear track detector, TechnoTrak, produced by the Chiyoda Technol Corporation, is evaluated. Plastic CR-39 nuclear track detectors are commonly used for precise time-integrated measurement of charged particles. Such measurements are crucial for diagnosing inertial confinement fusion (ICF) and high energy density (HED) experiments at the Omega Laser Facility, the Z Pulsed Power Facility, and the National Ignition Facility. The response of TechnoTrak CR-39 detectors was tested with protons produced from DD and D3He fusion reactions at the MIT linear ion accelerator. The results indicate that TechnoTrak CR-39 detectors exhibit high detection efficiency over a wide proton energy range (∼1−5 MeV), remain sensitive to protons up to ∼9 MeV, and have lower intrinsic noise than widely used TASTRAKTM CR-39 produced by Track Analysis Systems Ltd. This wide detectable energy range and low noise floor may benefit future HED and ICF experiments requiring low background levels and broad proton energy sensitivity.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessEvaluation of the high-performance TechnoTrak CR-39 for detection of 1–9 MeV fusion protons
In this paper, the MeV-proton response of a high-sensitivity, low-noise CR-39 nuclear track detector, TechnoTrak, produced by the Chiyoda Technol Corporation, is evaluated. Plastic CR-39 nuclear track detectors are commonly used for precise time-integrated measurement of charged particles. Such measurements are crucial for diagnosing inertial confinement fusion (ICF) and high energy density (HED) experiments at the Omega Laser Facility, the Z Pulsed Power Facility, and the National Ignition Facility. The response of TechnoTrak CR-39 detectors was tested with protons produced from DD and D3He fusion reactions at the MIT linear ion accelerator. The results indicate that TechnoTrak CR-39 detectors exhibit high detection efficiency over a wide proton energy range (∼1−5 MeV), remain sensitive to protons up to ∼9 MeV, and have lower intrinsic noise than widely used TASTRAKTM CR-39 produced by Track Analysis Systems Ltd. This wide detectable energy range and low noise floor may benefit future HED and ICF experiments requiring low background levels and broad proton energy sensitivity.
- Open Access
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Regularized inversion of optical Thomson scattering spectra for improved determination of plasma parameter evolution
Optical Thomson scattering spectra, particularly those measured in the collective scattering regime, are difficult to interpret due to non-linearity in the forward mapping from the electron and ion velocity distributions to the Thomson-scattered spectrum. Inversion routines often fit a spectrum to plasma parameters by minimizing a simple weighted residual sum of squares (RSS), but such routines frequently converge to solutions that are consistent with the measured data but exhibit unphysical oscillations of the fitted parameters within the uncertainty bounds of the data. This study explores one possible solution to this problem by minimizing a modified objective function that includes a regularization term penalizing solutions that evolve on unphysical timescales. A procedure for determining the optimal regularization weight hyperparameter is described. The resulting optimized regularized inversion scheme is demonstrated to avoid physically improbable but weighted-RSS-degenerate solutions and converge to a better overall description of the synthetic plasma parameters. For two of the synthetic test problems that the procedure was used on, the RSS of the best-fit parameter profiles relative to the ground truth was, on average, 0.31 and 0.65 times the RSS from the corresponding unregularized fits. For the third synthetic test problem, which involved discontinuous plasma parameters, the regularization scheme can accurately fit the plasma evolution around the discontinuity but not directly on the discontinuity.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Open AccessRegularized inversion of optical Thomson scattering spectra for improved determination of plasma parameter evolution
Optical Thomson scattering spectra, particularly those measured in the collective scattering regime, are difficult to interpret due to non-linearity in the forward mapping from the electron and ion velocity distributions to the Thomson-scattered spectrum. Inversion routines often fit a spectrum to plasma parameters by minimizing a simple weighted residual sum of squares (RSS), but such routines frequently converge to solutions that are consistent with the measured data but exhibit unphysical oscillations of the fitted parameters within the uncertainty bounds of the data. This study explores one possible solution to this problem by minimizing a modified objective function that includes a regularization term penalizing solutions that evolve on unphysical timescales. A procedure for determining the optimal regularization weight hyperparameter is described. The resulting optimized regularized inversion scheme is demonstrated to avoid physically improbable but weighted-RSS-degenerate solutions and converge to a better overall description of the synthetic plasma parameters. For two of the synthetic test problems that the procedure was used on, the RSS of the best-fit parameter profiles relative to the ground truth was, on average, 0.31 and 0.65 times the RSS from the corresponding unregularized fits. For the third synthetic test problem, which involved discontinuous plasma parameters, the regularization scheme can accurately fit the plasma evolution around the discontinuity but not directly on the discontinuity.
- 21 October 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (17) , 175102
Revealing the Structure and Dynamics of Self-Generated Electric and Magnetic Fields Near Plasma Stagnation in Laser-Driven Hohlraums
By coupling newly developed triparticle charged particle radiography with radiography reconstruction algorithms and novel reconstruction postprocessing techniques, the spatial structure and time evolution of self-generated electric and magnetic fields in laser-driven vacuum hohlraums have been quantitatively revealed. Through high-fidelity data from a series of experiments, it is shown that late in the hohlraum evolution (after the end of laser drive) these fields are strongly correlated in both space and time, providing evidence that their evolution is primarily dominated by advection with the plasma flow. At these late times, plasma flow velocities inferred from both gross radiography analysis and field reconstructions (and corroborated with Thomson scattering measurements) indicate that the plasma is approaching stagnation near the hohlraum axis. These experiments provide not only new physical insight into spontaneously generated hohlraum fields, but also provide important spatially and temporally resolved information for future benchmarking of numerical codes.
- 21 October 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (17) , 175102
Revealing the Structure and Dynamics of Self-Generated Electric and Magnetic Fields Near Plasma Stagnation in Laser-Driven Hohlraums
By coupling newly developed triparticle charged particle radiography with radiography reconstruction algorithms and novel reconstruction postprocessing techniques, the spatial structure and time evolution of self-generated electric and magnetic fields in laser-driven vacuum hohlraums have been quantitatively revealed. Through high-fidelity data from a series of experiments, it is shown that late in the hohlraum evolution (after the end of laser drive) these fields are strongly correlated in both space and time, providing evidence that their evolution is primarily dominated by advection with the plasma flow. At these late times, plasma flow velocities inferred from both gross radiography analysis and field reconstructions (and corroborated with Thomson scattering measurements) indicate that the plasma is approaching stagnation near the hohlraum axis. These experiments provide not only new physical insight into spontaneously generated hohlraum fields, but also provide important spatially and temporally resolved information for future benchmarking of numerical codes.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Design of an in-vacuum manipulator for nuclear diagnostics development at the MIT linear electrostatic ion accelerator
An ultrahigh vacuum compatible manipulator known as the Diagnostic Manipulating Element (DiME) has been developed for the MIT Linear Electrostatic Ion Accelerator (LEIA) facility. The system was designed to reduce the resources dedicated toward the calibration process for step-range filters CR-39 based proton spectrometers used in inertial confinement fusion experiments at the Lawrence Livermore National Ignition Facility and the University of Rochester’s OMEGA Laser Facility. To accurately account for variations in nominal filter thicknesses when analyzing experimental data, the spectrometers are calibrated at the MIT LEIA facility prior to use at other facilities. The system supports rapid prototyping and can reduce the time necessary for spectrometer calibration by 50%. The modular design of the DiME is described in this article to facilitate the implementation of similar design methods at other facilities focused on the development of nuclear fusion technologies.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Design of an in-vacuum manipulator for nuclear diagnostics development at the MIT linear electrostatic ion accelerator
An ultrahigh vacuum compatible manipulator known as the Diagnostic Manipulating Element (DiME) has been developed for the MIT Linear Electrostatic Ion Accelerator (LEIA) facility. The system was designed to reduce the resources dedicated toward the calibration process for step-range filters CR-39 based proton spectrometers used in inertial confinement fusion experiments at the Lawrence Livermore National Ignition Facility and the University of Rochester’s OMEGA Laser Facility. To accurately account for variations in nominal filter thicknesses when analyzing experimental data, the spectrometers are calibrated at the MIT LEIA facility prior to use at other facilities. The system supports rapid prototyping and can reduce the time necessary for spectrometer calibration by 50%. The modular design of the DiME is described in this article to facilitate the implementation of similar design methods at other facilities focused on the development of nuclear fusion technologies.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Impact of x rays on the sensitivity of CR-39 detectors to 2.4-MeV protons
Solid-state nuclear track detectors, such as CR-39, lose sensitivity when subjected to doses of x rays on the order of 1 Gy in nuclear-fusion relevant experiments. As a result, the formed tracks have, in general, smaller maximum radii and shallower maximum depths. Presented here are experiments using atomic force microscopy to measure the CR-39 sensitivity parameter Vt/Vb, the ratio of track to bulk etch rates, for ∼2.4 MeV protons. The measurements revealed that absorbed x-ray doses of the order of 1 Gy reduced the CR-39 track diameters by a factor of 3 from ∼1200 to ∼400 nm and reduced the track depths by an order of magnitude from ∼550 to ∼50 nm. The corresponding change in the sensitivity parameter was inferred and found to have substantially decreased from ∼1.1 to ≲1.01. Doses in excess of 0.5 Gy reduced the track diameter, at an etch time of 2 h, below the 1.0 μm limit typical of optical microscopy methods used when scanning large, i.e., ≳25 cm2, samples of CR-39. The findings suggest that the mechanism of sensitivity loss is driven by x-ray induced cross-linking of the bulk CR-39. The enhanced cross-linking reduces the solubility of the material along charged-particle trajectories compared with that of the bulk material. Representative absorbed doses of between 0.01 and 1 Gy in CR-39 on OMEGA and NIF in typical experimental configurations are then compared with the results.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Impact of x rays on the sensitivity of CR-39 detectors to 2.4-MeV protons
Solid-state nuclear track detectors, such as CR-39, lose sensitivity when subjected to doses of x rays on the order of 1 Gy in nuclear-fusion relevant experiments. As a result, the formed tracks have, in general, smaller maximum radii and shallower maximum depths. Presented here are experiments using atomic force microscopy to measure the CR-39 sensitivity parameter Vt/Vb, the ratio of track to bulk etch rates, for ∼2.4 MeV protons. The measurements revealed that absorbed x-ray doses of the order of 1 Gy reduced the CR-39 track diameters by a factor of 3 from ∼1200 to ∼400 nm and reduced the track depths by an order of magnitude from ∼550 to ∼50 nm. The corresponding change in the sensitivity parameter was inferred and found to have substantially decreased from ∼1.1 to ≲1.01. Doses in excess of 0.5 Gy reduced the track diameter, at an etch time of 2 h, below the 1.0 μm limit typical of optical microscopy methods used when scanning large, i.e., ≳25 cm2, samples of CR-39. The findings suggest that the mechanism of sensitivity loss is driven by x-ray induced cross-linking of the bulk CR-39. The enhanced cross-linking reduces the solubility of the material along charged-particle trajectories compared with that of the bulk material. Representative absorbed doses of between 0.01 and 1 Gy in CR-39 on OMEGA and NIF in typical experimental configurations are then compared with the results.
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Errors in the field reconstruction using CR-39 proton radiographs with high fluence variation
CR-39 proton radiography is an experimental charged-particle backlighter platform fielded and used at OMEGA and the NIF to image electric and magnetic fields in a subject plasma. Processing a piece of CR-39 involves etching it in hot NaOH, and the etch time can greatly impact the background-to-signal ratio (BSR) in low-fluence (≲4 × 104 cm−2) regions and detection efficiency in high-fluence regions (≳7 × 105 cm−2). For CR-39 data with high fluence variation, these effects mean that any single etch time will result in ≳15% error in the measured signal in either the high- or low-fluence regions. This study aims to quantify the impact of the etch time on the BSR and efficiency losses and how these affect the field reconstruction. Experiments at the MIT Linear Electrostatic Ion Accelerator provided empirical values of the BSR and efficiency losses as a function of the fluence and etch time for fluences ranging from 3 × 103 to 7 × 105 cm−2. Synthetic radiographs were generated with known fields and modulated based on empirical values of BSR and efficiency losses. The fields were reconstructed using a Monge–Ampère code with the modulated radiographs as input. The results indicate that combining short and long etches allows for more accurate analysis of radiographs with high fluence variation, with the mean squared error of the reconstructed fields decreasing by factors of 1.2–7 compared to the reconstructions using only one etch time.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessErrors in the field reconstruction using CR-39 proton radiographs with high fluence variation
CR-39 proton radiography is an experimental charged-particle backlighter platform fielded and used at OMEGA and the NIF to image electric and magnetic fields in a subject plasma. Processing a piece of CR-39 involves etching it in hot NaOH, and the etch time can greatly impact the background-to-signal ratio (BSR) in low-fluence (≲4 × 104 cm−2) regions and detection efficiency in high-fluence regions (≳7 × 105 cm−2). For CR-39 data with high fluence variation, these effects mean that any single etch time will result in ≳15% error in the measured signal in either the high- or low-fluence regions. This study aims to quantify the impact of the etch time on the BSR and efficiency losses and how these affect the field reconstruction. Experiments at the MIT Linear Electrostatic Ion Accelerator provided empirical values of the BSR and efficiency losses as a function of the fluence and etch time for fluences ranging from 3 × 103 to 7 × 105 cm−2. Synthetic radiographs were generated with known fields and modulated based on empirical values of BSR and efficiency losses. The fields were reconstructed using a Monge–Ampère code with the modulated radiographs as input. The results indicate that combining short and long etches allows for more accurate analysis of radiographs with high fluence variation, with the mean squared error of the reconstructed fields decreasing by factors of 1.2–7 compared to the reconstructions using only one etch time.
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Quantifying the effects of neutron fluence on proton signal retention in CR-39
This paper reports on investigations on the impact of higher neutron fluences on the detection efficiency of protons with CR-39, a charged particle track detector. CR-39 is widely used as a diagnostic for inertial fusion applications and is an integral component of numerous particle diagnostics at the OMEGA laser facility and National Ignition Facility. As experiments continue to produce higher and higher yields, existing diagnostics are impacted by higher particle fluences than they were originally designed for. This paper presents data from experiments measuring proton signal on pieces of CR-39 with different levels of neutron fluence with two different etch times. The experiments show a decrease in signal recovery with increased neutron fluence, which is exacerbated at longer etch times. At 3 h etch time, data suggest a 17% ± 7% signal loss at 1.3 × 105 neutron-induced tracks per cm2 and a 67% ± 21% loss at 6 h etch time. Careful signal isolation techniques can recover most of the proton tracks even with moderate neutron fluence.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessQuantifying the effects of neutron fluence on proton signal retention in CR-39
This paper reports on investigations on the impact of higher neutron fluences on the detection efficiency of protons with CR-39, a charged particle track detector. CR-39 is widely used as a diagnostic for inertial fusion applications and is an integral component of numerous particle diagnostics at the OMEGA laser facility and National Ignition Facility. As experiments continue to produce higher and higher yields, existing diagnostics are impacted by higher particle fluences than they were originally designed for. This paper presents data from experiments measuring proton signal on pieces of CR-39 with different levels of neutron fluence with two different etch times. The experiments show a decrease in signal recovery with increased neutron fluence, which is exacerbated at longer etch times. At 3 h etch time, data suggest a 17% ± 7% signal loss at 1.3 × 105 neutron-induced tracks per cm2 and a 67% ± 21% loss at 6 h etch time. Careful signal isolation techniques can recover most of the proton tracks even with moderate neutron fluence.
- Open Access
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Image plate multi-scan response to fusion protons in the range of 1–14 MeV
Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Open AccessImage plate multi-scan response to fusion protons in the range of 1–14 MeV
Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.
- Open Access
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Characterization of the image plate multi-scan response to mono-energetic x-rays
Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Open AccessCharacterization of the image plate multi-scan response to mono-energetic x-rays
Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.
- Open Access
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates
Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Open AccessCharacterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates
Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.