SSSujeet Kumar Sinha

Sujeet Kumar Sinha

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sujeet Kumar Sinha has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Tribological response of UHMWPE lubricated with nanomaterials blended jatropha oil

    by Sandip Kumar Nayak, Sujeet Kumar Sinha, Raj Kumar Pandey

    Growing demands for environmental sustainability and biodegradability have intensified research on bio-based lubricants extracted from renewable resources using nano-additives to enhance its tribological performance. Thus, this study investigates the tribological responses of ultra-high-molecular-weight polyethylene (UHMWPE) lubricated with jatropha oil blended with graphite, graphene, and molybdenum disulfide (MoS 2 ) nanoparticles. These nanoparticles were blended in jatropha oil having concentrations of 0.25, 0.5 and 1 wt.%. The addition of nanoparticles increased both viscosity and thermal conductivity of the blended oil. Tribological tests were conducted at different PV values using a pin-on-disc configuration in accordance with ASTM G99-05 standard. Significant reductions in the coefficient of friction (COF) and specific wear rate (SWR) of UHMWPE have been found with nanoparticles blended oils. MoS 2 exhibited the lowest COF, achieving approximately 35% reduction, while graphite yielded the lowest SWR with approximately 52% reduction for 1 wt.% concentration. Increase in the sliding speed further reduced the COF and SWR due to better lubricating film formation at the interfaces.

  • Open Access

    Academic and industrial tribology research in India—Current status

    by Sujeet K. Sinha

    With the recent economic developments in India and a big thrust towards green technology and sustainability, tribology research has diversified from the industrial maintenance and lubricant centric tribology of few decades ago to new areas such as nanotribology, bio-tribology, smart coatings, wind turbine gears, green tribology etc. In this paper, a brief overview of the current research activities in tribological research in India will be presented. The paper is divided into industrial and academic research, and also, their status of collaborations is explored. The industry has continued to work on the problems related to the maintenance of bearings, lubrication of machineries, mining equipment etc., but some new issues are presently being focused. Some of these examples are, problems related to wind turbine gears, hydrogen energy tribology, electric vehicle tribology, ship propeller, nuclear powerplant tribology, bio-tribology and so on. In the academic environment, several new topics are being researched in different university/institute research labs. Bio-tribology and coatings have gained much momentum in academic research but there is also sufficient push towards new and environmentally friendly lubricant and grease additives for non-ferrous alloys etc. This paper will also provide some of the issues faced in industrial and academic tribological research arenas in India and how perhaps those issues could be tackled in the near future.

  • Tribological performances of polymeric plain bearings made of epoxy matrix with UHMWPE, MoS 2 , Kevlar and base oil as the fillers

    by Neha Singh, Sujeet K. Sinha

    Thermal, mechanical and tribological performances of epoxy-based composites, filled with UHMWPE, MoS 2 and Kevlar TM or base oil in different proportions, were investigated. Friction coefficient and specific wear rate were examined by a block-on-cylinder tribotester in a dry sliding condition under variable contact pressure and sliding velocities. It was found that the composite with in-situ base oil possesses the lowest coefficient of friction (0.056) and highest wear resistance (5.77 × 10 −6 mm 3 /Nm) at relatively high PV factor (product of contact pressure and sliding velocity) of 37 MPa-m/s when compared to other composites. Kevlar-filled composite provided low wear rate at very high PV factor of 52.5 MPa-m/s.


  • Open Access

    Tribological Studies of Hybrid Composites of Epoxy with Solid (UHMWPE) and Liquid (Squalane) Lubricant Fillers

    by Sujeet K. Sinha, Naoya Hatano, Tomoko Hirayama

    Epoxy-UHMWPE composites were filled with squalane, a hydrogenated form of naturally occurring hydrocarbon lubricant, squalene. The hybrid composite composition of 15 mass% of UHMWPE, 2 mass% of squalane and the rest epoxy was found to be the optimum with the coefficient of friction of 0.15 and the specific wear rate of 3.29 × 10−6 mm3/N.m when slid in dry condition against a stainless-steel disk on a pin-on-disc apparatus. The sliding speed and the nominal pressure were kept as 0.5 m/s and 1.27 MPa, respectively, and the sliding distance was 4.5 km for each test. The FESEM (Field Emission Scanning Electron Microscope) and 3D profilometry studies showed that the formation of thin uniform transfer layers of UHMWPE on the wear track and the pin surface were responsible for low friction and high wear durability. The transfer film thickness was in the range of 0.8-1 μm. The presence of UHMWPE particles in the matrix helped improve tribology of pure epoxy even though the hardness was reduced somewhat. Squalane also helped to reduce friction. It is expected that such kind of hybrid composites may find applications as bearing materials.


  • Effects of Soaking in Water, Base Oil, Ionic Liquid, and Grease of an Epoxy/UHMWPE/MoS2 Composite on Mechanical and Tribological Properties

    by Neha Singh, Sujeet K. Sinha

    Liquid absorption and tribological studies of epoxy-based composite with ultra-high molecular weight polyethylene (UHMWPE) and MoS2, sliding against steel were conducted. Composites, as coating and as a bulk, were soaked in water, base oil, ionic liquid and lithium-based grease for different intervals of days or months. Liquid weight% gain was more in polar liquids when compared to non-polar. Coated composite soaked in grease for 10 days showed coefficient of friction of 0.08 with wear-life of more than 1 million cycles and wear rate of 1.7×10−8 mm3/Nm. Bulk polymer composite soaked in grease for 180 days provided the least coefficient of friction of 0.06 and specific wear rate of 2.60×10−7 mm3/Nm.


  • Tribological Studies of Epoxy Composites With UHMWPE and MoS2 Fillers Coated on Bearing Steel: Dry Interface and Grease Lubrication

    by Neha Singh, Sujeet K. Sinha

    Epoxy with ultra-high molecular weight polyethylene (UHMWPE) and MoS2 fillers was coated on a bearing steel (SAE 52100). Frictional and wear properties of the coated samples in sliding contact were investigated on a pin-on-disc tribometer under a normal load of 10 N and linear sliding speed of 1 m/s against a bearing steel ball. The optimized coating composition (72 wt% Epoxy + 7 wt% hardener + 18 wt% UHMWPE + 3 wt% MoS2) showed highly improved tribological properties compared to pure epoxy and other epoxy-based composites. There was 75% reduction in the coefficient of friction (COF) in dry interfacial condition (COF reduced from 0.2 to 0.05) over pure epoxy and 80% reduction with grease as the lubricant. The specific wear rate of the composite was lower by five orders of magnitude over that of pure epoxy. Other mechanical properties such as hardness, tensile strength, and Young's modulus of the composite showed increments of 86%, 121%, and 43%, respectively, with respect to those of pure epoxy. 2-3 wt% of MoS2 had drastic effects on improving strength and reducing friction and wear of the composites. For dry sliding, initial abrasive and adhesive wear mechanisms led to transfer film formation on the steel counterface and the shearing was mainly within the transfer film. For the grease lubricated case, a thin layer of grease helped in shearing, and the transfer film formation was avoided. This epoxy based composite will have applications as tribological coatings for journal bearings.


  • Effects of UHMWPE Filler on the Tribological and Mechanical Properties of Biocompatible Epoxies

    by Kalathil A. Arshad, Jaswant K. Hirwani, Sujeet K. Sinha

    The effects of ultra-high molecular weight polyethylene (UHMWPE) as filler on two biocompatible epoxies on tribological and mechanical properties were studied. SU-8 and Structalit 8801 (a trade name) were the two biocompatible epoxies selected for this investigation. UHMWPE powder (40-48 μm particle size) was added to the selected epoxies to tailor their mechanical and tribological properties. In dry sliding test, after adding 25 weight percentage (wt%) of UHMWPE particles, the coefficient of friction (COF) reduced by 79% for SU-8 and 67% for Structalit and the specific wear rate reduced by 92% and 58% for SU-8 and Structalit, respectively. FTIR analysis conducted on the samples indicated that there were no chemical bonding between UHMWPE fillers and the epoxy matrices. A biocompatibility test conducted on SU-8 cured with the hardener confirmed that the samples were not cytotoxic. Also, it was noted that the ductility ratio of SU-8 and Structalit increased by 71% and 40%, respectively with the addition of UHMWPE. These novel composites can find applications as bio materials for tribologically demanding applications such as hip-knee joint implants, dental etc.


  • Tribological studies of epoxy and its composite coatings on steel in dry and lubricated sliding, (Tribology – Materials, Surfaces & Interfaces 2015 Vol. 9, No. 3, page 144–153)

    by V. Kumar, S. K. Sinha, A. K. Agarwal

    (2019). Tribological studies of epoxy and its composite coatings on steel in dry and lubricated sliding, (Tribology – Materials, Surfaces & Interfaces 2015 Vol. 9, No. 3, page 144–153). Tribology - Materials, Surfaces & Interfaces. Ahead of Print.

  • Tribological analysis of tip-cantilever made of SU-8, talc and PFPE composite

    by Jitendra K. Katiyar, Sujeet K. Sinha, Tomoko Hirayama, Arvind Kumar

    SU-8 polymer with talc particle (30 wt-%) and liquid perfluoropolyether (PFPE) (30 wt-%) fillers was used as a composite to fabricate conical tip-cantilever device. The composite tip demonstrated lower coefficient of friction (∼0.22) when compared with a tip made of pure SU-8 (∼0.65). Fluorine was detected on the wear track and the tip surface, which resulted from the transfer of PFPE from the tip to the wear track. The counterface made of pure SU-8 remained smooth and unworn when slid against the composite tip even after 1000 cycles of sliding. This composite with improved tribological and mechanical properties can be used for fabricating small component devices such as for micro-electro-mechanical systems (MEMS).


  • Wear Evaluation of Engine Piston Rings Coated With Dual Layer Hard and Soft Coatings

    by Vikram Kumar, Sujeet Kumar Sinha, Avinash Kumar Agarwal

    The main objective of this investigation is the evaluation of the performance of hard diamond-like-carbon (DLC) or tungsten carbide (WC) and soft (epoxy composite) dual-coatings on the internal combustion (IC) engine piston rings as a protective coating to reduce their wear. The rings were coated with DLC or WC by physical vapor deposition (PVD) method and then soft polymeric composite coating (epoxy/graphene/base oil SN150) was applied on the hard coating. The tribological tests of the dual-coated piston rings were conducted for 3.6 × 105 cycles at 1500 rpm engine speed and 50% rated load of a diesel engine in order to evaluate the wear performance of the piston rings. Scuffing of cylinder liner and piston rings interface was prevented by the application of polymer composites over the hard-coated rings. DLC hard and soft polymer composite dual coating over the top piston ring was found to have the lowest wear rate 1.69 × 10−12 mm3/N·m compared with the wear rate of dual coatings on the middle and lower rings.