Jeremy L. Fox
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeremy L. Fox has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Paul Tannous
Department of Pediatrics, Division of Cardiology, Ann and Robert H. Lurie Children's Hospital, Chicago, IL, USA
3 shared publications Agata Nytko
Center for Quality and Safety, Ann & Robert H. Lurie Children’s Hospital of Chicago, Chicago, USA
1 shared publication- Alan Nugent
Department of Pediatrics, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
1 shared publication Alan W. Nugent
Department of Pediatrics, Division of Cardiology, Ann & Robert H. Lurie Children’s Hospital of Chicago, Chicago, USA
1 shared publicationAmanda Eichstaedt
Department of Nursing, Ann & Robert H. Lurie Children’s Hospital of Chicago, Chicago, USA
1 shared publication- Amanda Hauck
Department of Pediatrics, Northwestern University Feinberg School of Medicine, Lurie Children’s Hospital, Chicago, IL 60611, USA
1 shared publication
Latest Publications
- 7 May 2026
- Published by Springer Nature in Pediatric Cardiology
ASD Diameter Indexed to Total Septal Length Outperforms Expert Opinion in Predicting Future Candidacy for Percutaneous ASD Closure
Percutaneous device closure is an attractive alternative to surgical closure of secundum atrial septal defects (ASDs) for those with suitable anatomy and size. Early surgery (< 2 years of age) allows for a more feasible "mini sternotomy" technique, while device closure is more commonly performed at an older age. Thus, the ability to predict future device-closure candidacy before 2 years of age is needed. Secundum ASD closures after 3 years of age from 2012 to 2023 at a single center were reviewed (n = 54). "Early" echocardiograms (obtained at 12-24 months of age) and "pre-intervention" echocardiograms (the last echo obtained prior to closure and after 36 months of age) for each patient were independently reviewed by echocardiographers who performed standardized measurements. The catheterization team reviewed the same echocardiograms and made recommendations on device closure candidacy. Reviewers were blinded to the paired echocardiograms and eventual interventions. There was moderate agreement in perceived device candidacy by catheterization team consensus between early and pre-intervention echocardiogram (Cohen's Kappa = 0.56, p < 0.001). In a multivariable model, the ratio of maximum ASD diameter indexed to total septal length (ASD/TSL) between 1 and 2 years of age was strongly predictive of eventual perceived candidacy for device closure (Area Under the Curve = 0.92, sensitivity 89%, specificity 89% at the optimal threshold of 0.46) outperforming expert consensus (sensitivity 81%, specificity of 77%). Patients with ASD/TSL < 0.46 on early echocardiograms are likely to be considered device candidates later in life.
- 7 May 2026
- Published by Springer Nature in Pediatric Cardiology
ASD Diameter Indexed to Total Septal Length Outperforms Expert Opinion in Predicting Future Candidacy for Percutaneous ASD Closure
Percutaneous device closure is an attractive alternative to surgical closure of secundum atrial septal defects (ASDs) for those with suitable anatomy and size. Early surgery (< 2 years of age) allows for a more feasible "mini sternotomy" technique, while device closure is more commonly performed at an older age. Thus, the ability to predict future device-closure candidacy before 2 years of age is needed. Secundum ASD closures after 3 years of age from 2012 to 2023 at a single center were reviewed (n = 54). "Early" echocardiograms (obtained at 12-24 months of age) and "pre-intervention" echocardiograms (the last echo obtained prior to closure and after 36 months of age) for each patient were independently reviewed by echocardiographers who performed standardized measurements. The catheterization team reviewed the same echocardiograms and made recommendations on device closure candidacy. Reviewers were blinded to the paired echocardiograms and eventual interventions. There was moderate agreement in perceived device candidacy by catheterization team consensus between early and pre-intervention echocardiogram (Cohen's Kappa = 0.56, p < 0.001). In a multivariable model, the ratio of maximum ASD diameter indexed to total septal length (ASD/TSL) between 1 and 2 years of age was strongly predictive of eventual perceived candidacy for device closure (Area Under the Curve = 0.92, sensitivity 89%, specificity 89% at the optimal threshold of 0.46) outperforming expert consensus (sensitivity 81%, specificity of 77%). Patients with ASD/TSL < 0.46 on early echocardiograms are likely to be considered device candidates later in life.
- Open Access
- 20 March 2026
- Published by Springer Nature in Journal of Perinatology
- Vol. 46 (10) , 1-8
Catheter and echocardiographic-focused management of primary pulmonary vein stenosis in premature infants: a single center 5-year experience
Background/Objectives: We describe the outcomes of pulmonary vein stenosis treatment in a cohort of premature infants using an assertive percutaneous management strategy with echocardiography as the primary method of surveillance. Subjects/Methods: This retrospective study included fifteen premature infants (median 24 weeks gestational age) that underwent pulmonary vein intervention from 2018-2023. The primary outcome was patient survival rate, and the secondary outcome was pulmonary vein preservation rate. Results: The estimated patient survival was 100% and 89% at 1 and 2 years after diagnosis. The pulmonary vein preservation rate was 88% and 83% at 1 and 2 years. Patients received a median of 4 echocardiograms between each cardiac catheterization and an average of 1 CT scan for every 1.5 years of observation. Conclusions: Pulmonary vein stenosis can be successfully managed with a percutaneous approach to pulmonary vein rehabilitation using echocardiography for surveillance, even in extremely premature infants.
- 20 March 2026
- Published by Springer Nature in Journal of Perinatology
- Vol. 46 (10) , 1-8
Open AccessCatheter and echocardiographic-focused management of primary pulmonary vein stenosis in premature infants: a single center 5-year experience
Background/Objectives: We describe the outcomes of pulmonary vein stenosis treatment in a cohort of premature infants using an assertive percutaneous management strategy with echocardiography as the primary method of surveillance. Subjects/Methods: This retrospective study included fifteen premature infants (median 24 weeks gestational age) that underwent pulmonary vein intervention from 2018-2023. The primary outcome was patient survival rate, and the secondary outcome was pulmonary vein preservation rate. Results: The estimated patient survival was 100% and 89% at 1 and 2 years after diagnosis. The pulmonary vein preservation rate was 88% and 83% at 1 and 2 years. Patients received a median of 4 echocardiograms between each cardiac catheterization and an average of 1 CT scan for every 1.5 years of observation. Conclusions: Pulmonary vein stenosis can be successfully managed with a percutaneous approach to pulmonary vein rehabilitation using echocardiography for surveillance, even in extremely premature infants.
- Open Access
- 23 September 2024
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 3 (11) , 102386
Hemodynamic Evaluation in Temporary Atrial Septal Defect Occlusion
- 23 September 2024
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 3 (11) , 102386
Open AccessHemodynamic Evaluation in Temporary Atrial Septal Defect Occlusion
- 29 November 2023
- Published by Springer Nature in Pediatric Radiology
- Vol. 54 (1) , 27-33
One children’s hospital planning and development process to adhere to the FDA recommendation that babies and young children undergo thyroid function testing after receiving an injection of iodine-containing contrast media for medical imaging
The United States (US) Food and Drug Administration (FDA) has issued multiple statements and guidelines since 2015 on the topic of thyroid function testing in babies and children through 3 years old after receiving iodinated contrast media for medical imaging exams. In April 2023, the FDA adjusted this recommendation to target babies and young children younger than 4 years of age who have a history of prematurity, very low birth weight, or underlying conditions which affect thyroid gland function, largely in response to solid arguments from expert statements from the American College of Radiology (ACR) which is endorsed by the Society for Pediatric Radiology (SPR), Pediatric Endocrinology Society (PES), and the Society for Cardiovascular Angiography & Intervention (SCAI). Herein we describe our approach and development of a clinical care guideline along with the steps necessary for implementation of the plan including alterations in ordering exams requiring iodinated contrast media, automatic triggering of lab orders, reporting, and follow-up, to address the 2022 FDA guidance statement to monitor thyroid function in children after receiving iodinated contrast media. The newly implemented clinical care guideline at Ann and Robert H. Lurie Children’s Hospital of Chicago remains applicable following the 2023 updated recommendation from the FDA. We will track patients less than 3 months of age who undergo thyroid function testing following computed tomography (CT), interventional radiology, and cardiac catheterization exams for which an iodinated contrast media is administered as a clinical care quality initiative. Graphical Abstract
- 29 November 2023
- Published by Springer Nature in Pediatric Radiology
- Vol. 54 (1) , 27-33
One children’s hospital planning and development process to adhere to the FDA recommendation that babies and young children undergo thyroid function testing after receiving an injection of iodine-containing contrast media for medical imaging
The United States (US) Food and Drug Administration (FDA) has issued multiple statements and guidelines since 2015 on the topic of thyroid function testing in babies and children through 3 years old after receiving iodinated contrast media for medical imaging exams. In April 2023, the FDA adjusted this recommendation to target babies and young children younger than 4 years of age who have a history of prematurity, very low birth weight, or underlying conditions which affect thyroid gland function, largely in response to solid arguments from expert statements from the American College of Radiology (ACR) which is endorsed by the Society for Pediatric Radiology (SPR), Pediatric Endocrinology Society (PES), and the Society for Cardiovascular Angiography & Intervention (SCAI). Herein we describe our approach and development of a clinical care guideline along with the steps necessary for implementation of the plan including alterations in ordering exams requiring iodinated contrast media, automatic triggering of lab orders, reporting, and follow-up, to address the 2022 FDA guidance statement to monitor thyroid function in children after receiving iodinated contrast media. The newly implemented clinical care guideline at Ann and Robert H. Lurie Children’s Hospital of Chicago remains applicable following the 2023 updated recommendation from the FDA. We will track patients less than 3 months of age who undergo thyroid function testing following computed tomography (CT), interventional radiology, and cardiac catheterization exams for which an iodinated contrast media is administered as a clinical care quality initiative. Graphical Abstract