Zhongyong Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhongyong Xu has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Bin Liu
College of Material Science and Engineering, Guangdong Research Center for Interfacial Engineering of Functional Materials, Guangdong Provincial Key Laboratory of New Energy Materials Service Safety, Shenzhen University, Shenzhen 518060, China
11 shared publications - Tianyi Qin
State Key Laboratory of Digital Medical Engineering Key Laboratory of Biomedical Engineering of Hainan Province School of Biomedical Engineering Hainan University Sanya Hainan P. R. China
6 shared publications Chao Song
College of Material Science and Engineering, Shenzhen University, Shenzhen 518060, China 2070343108@.szu.edu.cn
4 shared publicationsConghui Zeng
College of Material Science and Engineering, Shenzhen University, Shenzhen 518060, China 2070343079@.szu.edu.cn
4 shared publicationsLei Wang
College of Material Science and Engineering, Guangdong Provincial Key Laboratory of New Energy Materials Service Safety, Shenzhen University, Shenzhen 518060, China
4 shared publicationsTianyi Qin
Key Laboratory of Biomedical Engineering of Hainan Province, School of Biomedical Engineering, Hainan University, Haikou 570228, China
4 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by Elsevier in SSRN Electronic Journal
Displacement-triggered coassembly enables ratiometric fluorescent sensing of nandrolone phenylpropionate
Ratiometric fluorescent sensing of analytes with limited reactive groups and weak intrinsic visible absorption remains challenging. Here, we report a fluorescein-labeled human serum albumin (f-HSA) based host-guest probe for ratiometric sensing of nandrolone phenylpropionate (NPP), a poorly reactive steroid analyte. Unexpectedly, NPP induced opposite fluorescence changes at 522 and 650 nm, producing a concentration-dependent I650/I522 ratio over 2.5–30 μM and a visible green-to-orange color transition within 30 s. Mechanistic investigations supported a possible two-step signal-transduction pathway: NPP first competitively displaces CHAL-1 from HSA, followed by association of the released dye with excess NPP to form a compact co-assembled state with enhanced red emission. This displacement-coassembly mechanism is supported by fluorescence lifetime measurements, molecular docking, molecular dynamics simulations, and direct CHAL-1/NPP interaction experiments. The probe enabled quantitative analysis of spiked NPP in food and supplement extracts, with recoveries of 81.27–108.29% and relative standard deviations below 1.16%. The visible ratiometric response was further translated into paper-based and 3D-printed smartphone-assisted formats for portable screening, while NPP-responsive fluorescence changes were demonstrated in zebrafish larvae and mice. These results establish analyte-induced switching of supramolecular interactions as a strategy for generating ratiometric signals toward structurally challenging, weakly reactive analytes.
- 14 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDisplacement-triggered coassembly enables ratiometric fluorescent sensing of nandrolone phenylpropionate
Ratiometric fluorescent sensing of analytes with limited reactive groups and weak intrinsic visible absorption remains challenging. Here, we report a fluorescein-labeled human serum albumin (f-HSA) based host-guest probe for ratiometric sensing of nandrolone phenylpropionate (NPP), a poorly reactive steroid analyte. Unexpectedly, NPP induced opposite fluorescence changes at 522 and 650 nm, producing a concentration-dependent I650/I522 ratio over 2.5–30 μM and a visible green-to-orange color transition within 30 s. Mechanistic investigations supported a possible two-step signal-transduction pathway: NPP first competitively displaces CHAL-1 from HSA, followed by association of the released dye with excess NPP to form a compact co-assembled state with enhanced red emission. This displacement-coassembly mechanism is supported by fluorescence lifetime measurements, molecular docking, molecular dynamics simulations, and direct CHAL-1/NPP interaction experiments. The probe enabled quantitative analysis of spiked NPP in food and supplement extracts, with recoveries of 81.27–108.29% and relative standard deviations below 1.16%. The visible ratiometric response was further translated into paper-based and 3D-printed smartphone-assisted formats for portable screening, while NPP-responsive fluorescence changes were demonstrated in zebrafish larvae and mice. These results establish analyte-induced switching of supramolecular interactions as a strategy for generating ratiometric signals toward structurally challenging, weakly reactive analytes.
- 22 September 2026
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 62 (74) , 18464-18467
A GC-globulin-based supramolecular sensor array for discrimination of androgens and estrogens in urine
A three-channel fluorescent sensor array based on GC-globulin (GCG) has been developed for the discrimination of androgens and estrogens.
- 22 September 2026
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 62 (74) , 18464-18467
A GC-globulin-based supramolecular sensor array for discrimination of androgens and estrogens in urine
A three-channel fluorescent sensor array based on GC-globulin (GCG) has been developed for the discrimination of androgens and estrogens.
- Open Access
- 14 September 2026
- Published by Elsevier in SSRN Electronic Journal
Engineered albumin-based ratiometric fluorescent probe for rapid Cu2+ detection, bioimaging, and urinary Cu2+/Zn2+ analysis based on fluorocolorimetric array
Rapid and reliable monitoring of Cu2+ is important for environmental safety, biological imaging, and urinary copper assessment. Herein, we report a ratiometric fluorescent probe (MML@f-HSA) constructed by encapsulating a red-emissive hydrophobic dye MML into fluorescein-labelled human serum albumin (f-HSA). Covalently labelled fluorescein served as an internal reference, whereas the guest dye exhibited significantly quenched fluorescence through a Cu2+ binding-induced indicator-releasement mechanism. The probe showed a rapid ratiometric response (<10 s), high sensitivity (LOD: 8 nM), an eye-discernible orange-to-green fluorescence change, and good anti-interference capacity. It enabled quantitative measurement and on-site detection of spiked Cu2+ in tap water, drinking water, river water, soil leachate, and urine, as well as dual-channel ratiometric imaging of Cu2+ in living cells and zebrafish larvae. A six-channel sensor array was further built from two sets of RGB values recorded under two excitation/filter conditions. The array discriminated urinary Cu2+ from Zn2+, Cd2+, Fe3+, and Na+ and classified healthy-donor urine samples spiked with different Cu2+/Zn2+ concentrations to model urinary profiles relevant to early copper screening and zinc-therapy monitoring. This HSA-engineering strategy expands albumin-based supramolecular sensing and supports rapid Cu2+ detection, bioimaging, and high-throughput urinary analysis.
- 14 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEngineered albumin-based ratiometric fluorescent probe for rapid Cu2+ detection, bioimaging, and urinary Cu2+/Zn2+ analysis based on fluorocolorimetric array
Rapid and reliable monitoring of Cu2+ is important for environmental safety, biological imaging, and urinary copper assessment. Herein, we report a ratiometric fluorescent probe (MML@f-HSA) constructed by encapsulating a red-emissive hydrophobic dye MML into fluorescein-labelled human serum albumin (f-HSA). Covalently labelled fluorescein served as an internal reference, whereas the guest dye exhibited significantly quenched fluorescence through a Cu2+ binding-induced indicator-releasement mechanism. The probe showed a rapid ratiometric response (<10 s), high sensitivity (LOD: 8 nM), an eye-discernible orange-to-green fluorescence change, and good anti-interference capacity. It enabled quantitative measurement and on-site detection of spiked Cu2+ in tap water, drinking water, river water, soil leachate, and urine, as well as dual-channel ratiometric imaging of Cu2+ in living cells and zebrafish larvae. A six-channel sensor array was further built from two sets of RGB values recorded under two excitation/filter conditions. The array discriminated urinary Cu2+ from Zn2+, Cd2+, Fe3+, and Na+ and classified healthy-donor urine samples spiked with different Cu2+/Zn2+ concentrations to model urinary profiles relevant to early copper screening and zinc-therapy monitoring. This HSA-engineering strategy expands albumin-based supramolecular sensing and supports rapid Cu2+ detection, bioimaging, and high-throughput urinary analysis.
- 20 November 2025
- Published by Elsevier in Food Chemistry
- Vol. 498 (Pt 2) , 147182
Recognition of ochratoxins by a host-guest ratiometric fluorescent sensor array
- 20 November 2025
- Published by Elsevier in Food Chemistry
- Vol. 498 (Pt 2) , 147182
Recognition of ochratoxins by a host-guest ratiometric fluorescent sensor array
- 5 August 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 61 (72) , 13695-13698
Identification and quantification of human serum albumin from different sources by a fluorescence sensor array
Recombinant and wild-type human serum albumin are accurately distinguished by a rationally designed fluorescent sensor array.
- 5 August 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 61 (72) , 13695-13698
Identification and quantification of human serum albumin from different sources by a fluorescence sensor array
Recombinant and wild-type human serum albumin are accurately distinguished by a rationally designed fluorescent sensor array.
- 3 April 2024
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 60 (35) , 4691-4694
Ratiometric determination of etomidate based on an albumin-based indicator displacement assay (IDA)
The first fluorescent sensor based on the indicator displacement assay (IDA) for on-site determination of etomidate.
- 3 April 2024
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 60 (35) , 4691-4694
Ratiometric determination of etomidate based on an albumin-based indicator displacement assay (IDA)
The first fluorescent sensor based on the indicator displacement assay (IDA) for on-site determination of etomidate.
- 13 March 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 313, 124157
A novel dual-color fluorescent sensor with two pKas for on-site detection of pH in food
- 13 March 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 313, 124157
A novel dual-color fluorescent sensor with two pKas for on-site detection of pH in food
- 23 January 2024
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 261, 129723
Rational design of a FA1-targeting anti-interference fluorescent probe for the point-of-care testing of albuminuria
- 23 January 2024
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 261, 129723
Rational design of a FA1-targeting anti-interference fluorescent probe for the point-of-care testing of albuminuria
- 29 November 2023
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 465, 133104
Fast, portable, selective, and ratiometric determination of ochratoxin A (OTA) by a fluorescent supramolecular sensor
- 29 November 2023
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 465, 133104
Fast, portable, selective, and ratiometric determination of ochratoxin A (OTA) by a fluorescent supramolecular sensor