L. Sostero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
L. Sostero has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Matteo Ferrari
Institut d’Optique Graduate School Laboratoire Hubert Curien UMR 5516 CNRS Université Jean Monnet Saint‐Etienne France
4 shared publications - Sylvain Girard
Université Jean Monnet Saint-Etienne
4 shared publications A. Donzella
Dipartimento di Ingegneria Meccanica e Industriale, Universit degli Studi di Brescia, Brescia, Italy
2 shared publications- Davide Pagano
INFN, Sezione di Pavia
2 shared publications - Ruben Garcia Alia
CERN
2 shared publications - Ygor Q. Aguiar
CERN, CH-1211 Geneve, Switzerland
2 shared publications
Latest Publications
- Open Access
- 29 May 2025
- Published by IOP Publishing in Journal of Physics: Materials
- Vol. 8 (3) , 035003
Radiation-induced effects on commercial 3D printing materials exposed to high x-ray doses
Fused filament fabrication is among the most widely used 3D printing techniques, that allows to create complex devices from a continuous filament of a polymeric material. This adaptable technique has garnered considerable interest for the development of components functioning under severe radiation environments, including particle accelerators and nuclear reactors. In this work, we evaluated the radiation effects on several categories of commercial printing materials, namely the poly(lactic acid) (PLA), the acrylonitrile butadiene styrene (ABS), and a thermoplastic elastomer (TPE). Printing filaments have been exposed to x-rays (up to 160 keV) at 0.60 Gy s−1, from 45 kGy to 2 MGy. The results from tensile tests, thermal analyses (differential scanning calorimetry, thermogravimetric analysis, dynamic mechanical thermal analysis), and spectroscopy tests (Fourier transform infrared spectroscopy and Raman analysis) reveal a dose-dependent degradation of material properties, predominantly affecting mechanical properties rather than chemical and thermal ones. The PLA shows the lowest radiation tolerance among the three, dramatically decreasing the tensile strength above 100 kGy, while TPE and ABS reach a comparable mechanical degradation after 1 MGy and 2 MGy, respectively. Radiation-induced effects are investigated, and the degradation is primarily attributed to chain scission as the principal damage mechanism.
- 29 May 2025
- Published by IOP Publishing in Journal of Physics: Materials
- Vol. 8 (3) , 035003
Open AccessRadiation-induced effects on commercial 3D printing materials exposed to high x-ray doses
Fused filament fabrication is among the most widely used 3D printing techniques, that allows to create complex devices from a continuous filament of a polymeric material. This adaptable technique has garnered considerable interest for the development of components functioning under severe radiation environments, including particle accelerators and nuclear reactors. In this work, we evaluated the radiation effects on several categories of commercial printing materials, namely the poly(lactic acid) (PLA), the acrylonitrile butadiene styrene (ABS), and a thermoplastic elastomer (TPE). Printing filaments have been exposed to x-rays (up to 160 keV) at 0.60 Gy s−1, from 45 kGy to 2 MGy. The results from tensile tests, thermal analyses (differential scanning calorimetry, thermogravimetric analysis, dynamic mechanical thermal analysis), and spectroscopy tests (Fourier transform infrared spectroscopy and Raman analysis) reveal a dose-dependent degradation of material properties, predominantly affecting mechanical properties rather than chemical and thermal ones. The PLA shows the lowest radiation tolerance among the three, dramatically decreasing the tensile strength above 100 kGy, while TPE and ABS reach a comparable mechanical degradation after 1 MGy and 2 MGy, respectively. Radiation-induced effects are investigated, and the degradation is primarily attributed to chain scission as the principal damage mechanism.
- Open Access
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2570-2577
Dose Rate Effects in Ag-Doped Metaphosphate Glass Radiophotoluminescent Dosimeters Up to MGy Range
This work presents a comprehensive study of dose rate effects on Ag-doped metaphosphate glass radiophotoluminescent (RPL) dosimeters for doses ranging bewteen 1 Gy and 100 MGy. Data from multiple irradiation campaigns with diverse radiation fields, such as 60Co gamma radiation, X-rays with energy spectrum up to 100 keV, monoenergetic electron beams, and mixed fields offer valuable insights for accurate dosimetry in high-radiation environments. Dose rates ranging over 8 decades, from 0.1 kGy/h to 18 MGy/h are experimentally tested. Low dose rate effects can be observed at low doses; however, for doses higher than 100 kGy, both overestimation and underestimation can occur depending on the dose rate.
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2570-2577
Open AccessDose Rate Effects in Ag-Doped Metaphosphate Glass Radiophotoluminescent Dosimeters Up to MGy Range
This work presents a comprehensive study of dose rate effects on Ag-doped metaphosphate glass radiophotoluminescent (RPL) dosimeters for doses ranging bewteen 1 Gy and 100 MGy. Data from multiple irradiation campaigns with diverse radiation fields, such as 60Co gamma radiation, X-rays with energy spectrum up to 100 keV, monoenergetic electron beams, and mixed fields offer valuable insights for accurate dosimetry in high-radiation environments. Dose rates ranging over 8 decades, from 0.1 kGy/h to 18 MGy/h are experimentally tested. Low dose rate effects can be observed at low doses; however, for doses higher than 100 kGy, both overestimation and underestimation can occur depending on the dose rate.
- Open Access
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1821-1828
Characterization of Radiophotoluminescence Dosimeters Under X-Ray Irradiation at High Doses
A characterization of radiophotoluminescence (RPL) dosimeters at high doses of X-ray radiation for applications in high radiation areas is presented. Commercial FD-7 silver doped phosphate glasses (1.5 mm x 8.5 mm) in use at CERN for passive dosimetry are irradiated using commercial X-ray tubes. A 1.5 mm thick aluminium filter is used to harden the X-ray spectrum and improve dose homogeneity. Two irradiation campaigns are presented, targeting doses ranging from about 1.3 kGy to 0.46 MGy and dose rates from about 0.6 kGy/h to 6.3 kGy/h, respectively. Monte Carlo simulations performed with PHITS allowed the determination of a factor to convert the dose to water, into the average absorbed dose to RPL material. The found conversion factor is validated by the achieved measurements. The results evidence a satisfactory agreement between the absorbed doses delivered with X-rays and the readout results, based on Co-60 gamma calibration.
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1821-1828
Open AccessCharacterization of Radiophotoluminescence Dosimeters Under X-Ray Irradiation at High Doses
A characterization of radiophotoluminescence (RPL) dosimeters at high doses of X-ray radiation for applications in high radiation areas is presented. Commercial FD-7 silver doped phosphate glasses (1.5 mm x 8.5 mm) in use at CERN for passive dosimetry are irradiated using commercial X-ray tubes. A 1.5 mm thick aluminium filter is used to harden the X-ray spectrum and improve dose homogeneity. Two irradiation campaigns are presented, targeting doses ranging from about 1.3 kGy to 0.46 MGy and dose rates from about 0.6 kGy/h to 6.3 kGy/h, respectively. Monte Carlo simulations performed with PHITS allowed the determination of a factor to convert the dose to water, into the average absorbed dose to RPL material. The found conversion factor is validated by the achieved measurements. The results evidence a satisfactory agreement between the absorbed doses delivered with X-rays and the readout results, based on Co-60 gamma calibration.
- Open Access
- 29 November 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1059
Investigating the possibility of leakage detection in water distribution networks using cosmic ray neutrons in the thermal region
- 29 November 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1059
Open AccessInvestigating the possibility of leakage detection in water distribution networks using cosmic ray neutrons in the thermal region