Mahmoud M. S. Al-Suod
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mahmoud M. S. Al-Suod has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Abdullah Eial Awwad
Tafila Technical University
1 shared publication - Alaa Al-Quteimat
Tafila Technical University
1 shared publication Chorna Olha
Kremenchuk Mykhailo Ostrogradskyi National University, Kremenchuk, Ukraine
1 shared publication- Dmytro O. Zhuk
National University of Shipbuilding named after Admiral Makarov
1 shared publication - Maksym Kozlov
National University of Shipbuilding named after Admiral Makarov
1 shared publication Mohammad Zannon
Department of Mathematics, Tafila Technical University, At-Tafilah, Jordan
1 shared publication
Latest Publications
- 29 April 2025
- Published by Springer Nature
- p. 447-463
Modeling of Ship Power Systems with Semiconductor Propulsion Complexes and Advanced Power Quality Assurance Tools
- 29 April 2025
- Published by Springer Nature
- p. 447-463
Modeling of Ship Power Systems with Semiconductor Propulsion Complexes and Advanced Power Quality Assurance Tools
- Open Access
- 7 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 63237-63247
Forecasting Energy Consumption of a Mining Plant Using Artificial Neural Networks
This study addresses the issue of forecasting active and reactive power consumption at a mining and processing plant, aiming to improve the efficiency of energy resource management. It explores existing approaches to modelling and analysing electricity consumption, including methods for forecasting active power to accurately assess the energy needs of industrial enterprises, as well as methods for estimating reactive power required to compensate for reactive components and stabilize grid parameters. Using real electricity consumption data from an industrial enterprise, the completed training and research demonstrates the potential to forecast energy consumption for the next 24 to 48 hours using artificial neural networks with nonlinear autoregressive architecture. It also provides rationale for pre-processing initial data to enhance forecast accuracy. These approaches contribute to reducing capital and operating costs, improving the reliability and stability of energy systems, and optimising operating efficiency.
- 7 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 63237-63247
Open AccessForecasting Energy Consumption of a Mining Plant Using Artificial Neural Networks
This study addresses the issue of forecasting active and reactive power consumption at a mining and processing plant, aiming to improve the efficiency of energy resource management. It explores existing approaches to modelling and analysing electricity consumption, including methods for forecasting active power to accurately assess the energy needs of industrial enterprises, as well as methods for estimating reactive power required to compensate for reactive components and stabilize grid parameters. Using real electricity consumption data from an industrial enterprise, the completed training and research demonstrates the potential to forecast energy consumption for the next 24 to 48 hours using artificial neural networks with nonlinear autoregressive architecture. It also provides rationale for pre-processing initial data to enhance forecast accuracy. These approaches contribute to reducing capital and operating costs, improving the reliability and stability of energy systems, and optimising operating efficiency.
- Open Access
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (6) , 3215-3227
Fuzzy logic-based synchronization control system of generators under conditions of frequency instability
This article focuses on studying and addressing the issue of synchronizing diesel gas generator units (DGGU) in autonomous electric power system (AEPS) in the presence of significant voltage frequency fluctuations. MATLAB models of AEPS are being developed that will enable the study of generator connection procedures while operating under a full load. Fluctuations in the rotation frequency of a diesel gas unit can be simulated by generating a realistic random procedure and adding this random signal to the control circuit. In the present study, the authors simulated the generator synchronization process in the presence of random disturbances. This simulation results indicated that the presence of random voltage frequency fluctuations and a nonzero response time of the circuit breaker (which connects the generator to the bars of the main distribution board) may violate the synchronization conditions and result in significant current surges and voltage sags at the time of synchronization. In the present work, a block diagram of the generator synchronization system is proposed that uses fuzzy logic to control the synchronization process. Software tools were developed using the methods of conceptual simulation to control the generator synchronization process; these tools represent an automated operator working station.
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (6) , 3215-3227
Open AccessFuzzy logic-based synchronization control system of generators under conditions of frequency instability
This article focuses on studying and addressing the issue of synchronizing diesel gas generator units (DGGU) in autonomous electric power system (AEPS) in the presence of significant voltage frequency fluctuations. MATLAB models of AEPS are being developed that will enable the study of generator connection procedures while operating under a full load. Fluctuations in the rotation frequency of a diesel gas unit can be simulated by generating a realistic random procedure and adding this random signal to the control circuit. In the present study, the authors simulated the generator synchronization process in the presence of random disturbances. This simulation results indicated that the presence of random voltage frequency fluctuations and a nonzero response time of the circuit breaker (which connects the generator to the bars of the main distribution board) may violate the synchronization conditions and result in significant current surges and voltage sags at the time of synchronization. In the present work, a block diagram of the generator synchronization system is proposed that uses fuzzy logic to control the synchronization process. Software tools were developed using the methods of conceptual simulation to control the generator synchronization process; these tools represent an automated operator working station.
- Open Access
- 30 June 2023
- Published by International Information and Engineering Technology Association in Journal Européen des Systèmes Automatisés
- Vol. 56 (3) , 365-375
Influence of Time Delays on Network-Controlled Diesel Generator Performance
- 30 June 2023
- Published by International Information and Engineering Technology Association in Journal Européen des Systèmes Automatisés
- Vol. 56 (3) , 365-375
Open AccessInfluence of Time Delays on Network-Controlled Diesel Generator Performance